3 research outputs found

    Comparison of five methods for detection of carbapenemases in Enterobacterales with proposal of a new algorithm

    No full text
    Objectives: The aim of this study was to evaluate the performance of five different carbapenemase tests and to develop an algorithm which will permit the detection of most common and rare carbapenemases in routine microbiology laboratories. Methods: The immunochromatographic tests CARBA-5 (NG), RESIST-4 O.K.N.V. (Coris), the colorimetric beta-CARBA (BioRad), a newly developed carbapenem-inactivation method (CIM) supplemented with zinc (zCIM), and the Xpert Carba-R (Cepheid) were challenged with a collection of 189 molecularly characterized Enterobacterales isolates, including 146 carbapenemase producers (CPE): VIM (n = 48), OXA-48-like (n = 40), NDM (n = 29), KPC (n = 13), IMI (n = 9), IMP (n = 9), OXA-58 (n = 2), and GES (n = 2). Results: The overall sensitivity/specificity values for the five carbapenemase detection tests were 84.2% (CI 77.6-89.2%)/100% (CI 91.8-100%) for RESIST-4, 88.2% (CI 82.1-92.4%)/100% (CI 91.8-100%) for CARBA-5, 88.2% (CI 82.1-92.4%)/100% (CI 91.8-100%) for Xpert Carba-R, 73.7% (CI 66.2-80.0%)/100% (CI 93.4-99.0%) for beta-CARBA, and 97.4% (CI 87.9-99.6%)/97.7% (CI 87.9-99.6%) for zCIM. The four common carbapenemases (KPC, OXA-48-like, NDM, and VIM) were detected with >= 97.6% sensitivity by all tests except for beta-CARBA (76.6% (CI 68.4-83.2%)). IMI and GES were only detected by zCIM (sensitivity 90.9% (CI 62.3-98.4%)). Based on these results a new algorithm was developed, consisting of an immunochromatographic assay as the first test followed by zCIM, which allows detection of 99.3% of all carbapenemases assessed. Conclusions: Except for beta-CARBA, all methods showed excellent sensitivity/specificity for the detection of the four most frequent carbapenemases. With the new algorithm, rare variants can also be detected. It is rapid, simple, and inexpensive and can be performed in any microbiology laboratory, as no PCR equipment is required. L. Lucena Baeza, Clin Microbiol Infect 2019;25:1286.e9-1286.e15 (c) 2019 The Authors. Published by Elsevier Ltd on behalf of European Society of Clinical Microbiology and Infectious Diseases. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

    Evaluation of a quality improvement intervention to reduce anastomotic leak following right colectomy (EAGLE): pragmatic, batched stepped-wedge, cluster-randomized trial in 64 countries

    Get PDF
    Background Anastomotic leak affects 8 per cent of patients after right colectomy with a 10-fold increased risk of postoperative death. The EAGLE study aimed to develop and test whether an international, standardized quality improvement intervention could reduce anastomotic leaks. Methods The internationally intended protocol, iteratively co-developed by a multistage Delphi process, comprised an online educational module introducing risk stratification, an intraoperative checklist, and harmonized surgical techniques. Clusters (hospital teams) were randomized to one of three arms with varied sequences of intervention/data collection by a derived stepped-wedge batch design (at least 18 hospital teams per batch). Patients were blinded to the study allocation. Low- and middle-income country enrolment was encouraged. The primary outcome (assessed by intention to treat) was anastomotic leak rate, and subgroup analyses by module completion (at least 80 per cent of surgeons, high engagement; less than 50 per cent, low engagement) were preplanned. Results A total 355 hospital teams registered, with 332 from 64 countries (39.2 per cent low and middle income) included in the final analysis. The online modules were completed by half of the surgeons (2143 of 4411). The primary analysis included 3039 of the 3268 patients recruited (206 patients had no anastomosis and 23 were lost to follow-up), with anastomotic leaks arising before and after the intervention in 10.1 and 9.6 per cent respectively (adjusted OR 0.87, 95 per cent c.i. 0.59 to 1.30; P = 0.498). The proportion of surgeons completing the educational modules was an influence: the leak rate decreased from 12.2 per cent (61 of 500) before intervention to 5.1 per cent (24 of 473) after intervention in high-engagement centres (adjusted OR 0.36, 0.20 to 0.64; P < 0.001), but this was not observed in low-engagement hospitals (8.3 per cent (59 of 714) and 13.8 per cent (61 of 443) respectively; adjusted OR 2.09, 1.31 to 3.31). Conclusion Completion of globally available digital training by engaged teams can alter anastomotic leak rates. Registration number: NCT04270721 (http://www.clinicaltrials.gov)
    corecore