130 research outputs found

    Clinical Utility of D-Dimer for Rule-Out or Rule-In of Venous Thromboembolism in Syncope

    Get PDF
    Fig. 1 Diagnostic performance of D-dimer using two different assays in patients presenting with syncope. A Left: Receiver-operating characteristic curves quantifying the diagnostic performance of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red) for the diagnosis of venous thromboembolism (VTE). Right: Clinical application of D-dimer using the 2-level Wells-score with age-adjusted1 or fixed cutoffs versus the YEARS-algorithm with probability-adjusted cut offs2. B Left: Specificity for different cufoffs of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red) for the diagnosis of venous thromboembolism (VTE). Right: Percentage of patients ruled-in and correctly identified VTE patients for different cutoffs of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red). 1In patients 50 years or younger, D-dimer concentration < 0.5 mg/l was considered negative. For patients older than 50 years, we used the formula: age in years divided by 100. 2YEARS-algorithm: assessment of only three items from the Wells-score (clinical signs of deep vein thrombosis, hemoptysis, pulmonary embolism the most likely diagnosis) and using a D-dimer test threshold of 0.5 mg/l in presence, and 1.0 mg/l in absence of one of the YEARS-items. Keywords: Diagnostic testing; Pulmonary embolism; Syncop

    Atrial substrate characterization based on bipolar voltage electrograms acquired with multipolar, focal and mini-electrode catheters.

    Get PDF
    BACKGROUND Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters

    A single-beat algorithm to discriminate farfield from nearfield bipolar voltage electrograms from the pulmonary veins.

    Get PDF
    BACKGROUND Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation. METHODS During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled. BVEs were classified using four different machine learning algorithms based on four frequency domain (high-frequency power (PHF), low-frequency power (PLF), relative high power band, PHF ratio of neighbouring electrodes) and two time domain features (amplitude (Vmax), slew rate). The algorithm-based classification was compared to the true identification gained during the PVI and to a classification by cardiac electrophysiologists. RESULTS We included 335 BVEs from 57 consecutive patients. Using a single feature, PHF with a cut-off at 150 Hz showed the best overall accuracy for classification (79.4%). By combining PHF with Vmax, overall accuracy was improved to 82.7% with a specificity of 89% and a sensitivity of 77%. The overall accuracy was highest for the right inferior PV (96.6%) and lowest for the left superior PV (76.9%). The algorithm showed comparable accuracy to the classification by the EP specialists. CONCLUSIONS An automated farfield-nearfield discrimination based on two simple features from a single-beat BVE is feasible with a high specificity and comparable accuracy to the assessment by experienced cardiac electrophysiologists

    Sex-Related Differences in Patient Selection for and Outcomes after Pace and Ablate for Refractory Atrial Fibrillation: Insights from a Large Multicenter Cohort.

    Get PDF
    Background: A pace and ablate strategy may be performed in refractory atrial fibrillation with rapid ventricular response. Objective: We aimed to assess sex-related differences in patient selection and clinical outcomes after pace and ablate. Methods: In a retrospective multicentre study, patients undergoing AV junction ablation were studied. Sex-related differences in baseline characteristics, all-cause mortality, heart failure (HF) hospitalizations, and device-related complications were assessed. Results: Overall, 513 patients underwent AV junction ablation (median age 75 years, 50% men). At baseline, men were younger (72 vs. 78 years, p &lt; 0.001), more frequently had non-paroxysmal AF (82% vs. 72%, p = 0.006), had a lower LVEF (35% vs. 55%, p &lt; 0.001) and more frequently had cardiac resynchronization therapy (75% vs. 25%, p &lt; 0.001). Interventional complications were rare in both groups (1.2% vs. 1.6%, p = 0.72). Patients were followed for a median of 42 months in survivors (IQR 22-62). After 4 years of follow-up, the combined endpoint of all-cause death or HF hospitalization occurred more often in men (38% vs. 27%, p = 0.008). The same was observed for HF hospitalizations (22% vs. 11%, p = 0.021) and all-cause death (28% vs. 21%, p = 0.017). Sex category remained an independent predictor of death or HF hospitalization after adjustment for age, LVEF and type of stimulation. Lead-related complications, infections, and upgrade to ICD or CRT occurred in 2.1%, 0.2% and 3.5% of patients, respectively. Conclusions: Pace and ablate is safe with a need for subsequent device-related re-interventions in 5.8% over 4 years. We found significant sex-related differences in patient selection, and women had a more favourable clinical course after AV junction ablation

    Validation of a clinical model for predicting left versus right ventricular outflow tract origin of idiopathic ventricular arrhythmias.

    Get PDF
    BACKGROUND Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin

    Prohormones in the early diagnosis of cardiac syncope

    Get PDF
    Background--The early detection of cardiac syncope is challenging. We aimed to evaluate the diagnostic value of 4 novel prohormones, quantifying different neurohumoral pathways, possibly involved in the pathophysiological features of cardiac syncope: midregional-pro-A-type natriuretic peptide (MRproANP), C-terminal proendothelin 1, copeptin, and midregionalproadrenomedullin. Methods and Results--We prospectively enrolled unselected patients presenting with syncope to the emergency department (ED) in a diagnostic multicenter study. ED probability of cardiac syncope was quantified by the treating ED physician using a visual analogue scale. Prohormones were measured in a blinded manner. Two independent cardiologists adjudicated the final diagnosis on the basis of all clinical information, including 1-year follow-up. Among 689 patients, cardiac syncope was the adjudicated final diagnosis in 125 (18%). Plasma concentrations of MRproANP, C-terminal proendothelin 1, copeptin, and midregional-proadrenomedullin were all significantly higher in patients with cardiac syncope compared with patients with other causes (P < 0.001). The diagnostic accuracies for cardiac syncope, as quantified by the area under the curve, were 0.80 (95% confidence interval [CI], 0.76-0.84), 0.69 (95% CI, 0.64-0.74), 0.58 (95% CI, 0.52-0.63), and 0.68 (95% CI, 0.63-0.73), respectively. In conjunction with the ED probability (0.86; 95% CI, 0.82-0.90), MRproANP, but not the other prohormone, improved the area under the curve to 0.90 (95% CI, 0.87-0.93), which was significantly higher than for the ED probability alone (P=0.003). An algorithm to rule out cardiac syncope combining an MRproANP level of < 77 pmol/L and an ED probability of < 20% had a sensitivity and a negative predictive value of 99%. Conclusions--The use of MRproANP significantly improves the early detection of cardiac syncope among unselected patients presenting to the ED with syncope

    Neurocognitive function in patients with atrial fibrillation undergoing pulmonary vein isolation.

    Get PDF
    BACKGROUND Atrial fibrillation (AF) is associated with cognitive dysfunction. However, neurocognitive function in AF patients undergoing pulmonary vein isolation (PVI) has not been well studied. The aim of this analysis is to compare neurocognitive function in patients who did or did not undergo PVI. MATERIALS AND METHODS We used data from the Swiss Atrial Fibrillation Cohort study (Swiss-AF), a prospective, observational, multicenter study in Switzerland. Patients with documented AF were enrolled and data of 1,576 patients without history of PVI and with complete information on PVI status and neurocognitive function were used. Information on PVI was collected at baseline and during 1 year of follow-up. Neurocognitive testing was performed at baseline and after 1 year of follow-up, using the Montreal Cognitive Assessment (MoCA), trail making test (TMT) A and B, digit symbol substitution test (DSST) and semantic fluency test (SFT). To investigate the association of PVI with neurocognitive function, we use propensity score matching (1:3) and inverse probability of treatment weighting (IPTW). RESULTS The mean age of this population was 74 ± 8 years, 27.1% were women. Overall, 88 (5.5%) patients underwent PVI during 1 year of follow-up. Using ITPW (n = 1576), PVI was weakly associated with the MoCA score after adjusting for time since PVI, baseline MoCA score and other covariates (β (95%CI) 1.19 (0.05; 2.32), p = 0.04). In the propensity matched comparison (n = 352), there was no significant association between PVI and the MoCA score (β (95%CI) 1.04 (-0.19; 2.28), p = 0.1). There were no significant associations between PVI and cognitive function when using the TMT A and B, DSST or SFT independent of the method used. CONCLUSION In this population of AF patients, there was no consistent evidence of an association between PVI and neurocognitive function. CLINICAL TRIAL REGISTRATION [https://clinicaltrials.gov/], identifier [NCT02105844]

    Neurocognitive function in patients with atrial fibrillation undergoing pulmonary vein isolation

    Full text link
    BackgroundAtrial fibrillation (AF) is associated with cognitive dysfunction. However, neurocognitive function in AF patients undergoing pulmonary vein isolation (PVI) has not been well studied. The aim of this analysis is to compare neurocognitive function in patients who did or did not undergo PVI.Materials and methodsWe used data from the Swiss Atrial Fibrillation Cohort study (Swiss-AF), a prospective, observational, multicenter study in Switzerland. Patients with documented AF were enrolled and data of 1,576 patients without history of PVI and with complete information on PVI status and neurocognitive function were used. Information on PVI was collected at baseline and during 1 year of follow-up. Neurocognitive testing was performed at baseline and after 1 year of follow-up, using the Montreal Cognitive Assessment (MoCA), trail making test (TMT) A and B, digit symbol substitution test (DSST) and semantic fluency test (SFT). To investigate the association of PVI with neurocognitive function, we use propensity score matching (1:3) and inverse probability of treatment weighting (IPTW).ResultsThe mean age of this population was 74 ± 8 years, 27.1% were women. Overall, 88 (5.5%) patients underwent PVI during 1 year of follow-up. Using ITPW (n = 1576), PVI was weakly associated with the MoCA score after adjusting for time since PVI, baseline MoCA score and other covariates (β (95%CI) 1.19 (0.05; 2.32), p = 0.04). In the propensity matched comparison (n = 352), there was no significant association between PVI and the MoCA score (β (95%CI) 1.04 (−0.19; 2.28), p = 0.1). There were no significant associations between PVI and cognitive function when using the TMT A and B, DSST or SFT independent of the method used.ConclusionIn this population of AF patients, there was no consistent evidence of an association between PVI and neurocognitive function.Clinical trial registration[https://clinicaltrials.gov/], identifier [NCT02105844]
    corecore