133 research outputs found

    Assessment of tumour size in PET/CT lung cancer studies: PET- and CT-based methods compared to pathology

    Get PDF
    BACKGROUND: Positron emission tomography (PET) may be useful for defining the gross tumour volume for radiation treatment planning and for response monitoring of non-small cell lung cancer (NSCLC) patients. The purpose of this study was to compare tumour sizes obtained from CT- and various more commonly available PET-based tumour delineation methods to pathology findings. METHODS: Retrospective non-respiratory gated whole body [(18)F]-fluoro-2-deoxy-D-glucose PET/CT studies from 19 NSCLC patients were used. Several (semi-)automatic PET-based tumour delineation methods and manual CT-based delineation were used to assess the maximum tumour diameter. RESULTS: 50%, adaptive 41% threshold-based and contrast-oriented delineation methods showed good agreement with pathology after removing two outliers (R(2)=0.82). An absolute SUV threshold of 2.5 also showed a good agreement with pathology after the removal of 5 outliers (R(2): 0.79), but showed a significant overestimation in the maximum diameter (19.8 mm, p<0.05). Adaptive 50%, relative threshold level and gradient-based methods did not show any outliers, provided only small, non-significant differences in maximum tumour diameter (<4.7 mm, p>0.10), and showed fair correlation (R(2)>0.62) with pathology. Although adaptive 70% threshold-based methods showed underestimation compared to pathology (36%), it provided the best precision (SD: 14%) together with good correlation (R(2)=0.81). Good correlation between CT delineation and pathology was observed (R(2)=0.77). However, CT delineation showed a significant overestimation compared with pathology (3.8 mm, p<0.05). CONCLUSIONS: PET-based tumour delineation methods provided tumour sizes in agreement with pathology and may therefore be useful to define the (metabolically most) active part of the tumour for radiotherapy and response monitoring purposes

    Mast Cells in Kidney Transplant Biopsies With Borderline T Cell-mediated Rejection and Their Relation to Chronicity

    Get PDF
    Background. Mast cells are potential contributors to chronic changes in kidney transplants (KTx). Here, the role of mast cells (MCs) in KTx is investigated in patients with minimal inflammatory lesions. Methods. Fourty-seven KTx biopsies (2009-2018) with borderline pathological evidence for T cell-mediated rejection according to the Banff'17 Update were retrospectively included and corresponding clinical data was collected. Immunohistochemistry for tryptase was performed on formalin-fixed paraffin-embedded sections. Cortical MCs were counted and corrected for area (MC/mm²). Interstitial fibrosis was assessed by Sirius Red staining and quantified using digital image analysis (QuPath). Results. Increased MC number was correlated to donor age (spearman's r = 0.35, P = 0.022), deceased donor kidneys (mean difference = 0.74, t [32.5] = 2.21, P = 0.035), and delayed graft function (MD = 0.78, t [33.9] = 2.43, P = 0.020). Increased MC number was also correlated to the amount of interstitial fibrosis (r = 0.42, P = 0.003) but did not correlate with transplant function over time (r = -0.14, P = 0.36). Additionally, transplant survival 2 y post-biopsy was not correlated to MC number (mean difference = -0.02, t [15.36] = -0.06, P = 0.96). Conclusions. MC number in suspicious (borderline) for acute T cell-mediated rejection is correlated to interstitial fibrosis and time post-transplantation, suggesting MCs to be a marker for cumulative burden of tissue injury. There was no association between MCs and transplant function over time or transplant survival 2 y post-biopsy. It remains unclear whether MCs are just a bystander or have pro-inflammatory or anti-inflammatory effects in the KTx with minimal lesions.</p

    Магнитный контроль параметров ферромагнитных объектов методом высших гармоник

    Get PDF
    В данной работе объектом исследования являются контрольные образцы тороидальной формы из ферромагнитных сталей различных марок, изготовленные согласно ГОСТ 8.377-80, магнитные параметры которых исследуются с помощью разработанной многопараметровой установки для измерения магнитных характеристик MS-1.In this work, the object of the study is the control samples of toroidal shape of ferromagnetic steels of different brands, made according to GOST 8.377-80, the magnetic parameters of which are investigated using the developed multiparameter installation for measuring the magnetic characteristics of MS-1

    18F-FDG PET during stereotactic body radiotherapy for stage I lung tumours cannot predict outcome: a pilot study

    Get PDF
    (18)F-Fluorodeoxyglucose positron emission tomography (FDG PET) has been used to assess metabolic response several months after stereotactic body radiotherapy (SBRT) for early-stage non-small cell lung cancer. However, whether a metabolic response can be observed already during treatment and thus can be used to predict treatment outcome is undetermined. Ten medically inoperable patients with FDG PET-positive lung tumours were included. SBRT consisted of three fractions of 20 Gy delivered at the 80% isodose at days 1, 6 and 11. FDG PET was performed before, on day 6 immediately prior to administration of the second fraction of SBRT and 12 weeks after completion of SBRT. Tumour metabolism was assessed semi-quantitatively using the maximum standardized uptake value (SUV(max)) and SUV(70%). After the first fraction, median SUV(max) increased from 6.7 to 8.1 (p = 0.07) and median SUV(70%) increased from 5.7 to 7.1 (p = 0.05). At 12 weeks, both median SUV(max) and median SUV(70%) decreased by 63% to 3.1 (p = 0.008) and to 2.5 (p = 0.008), respectively. SUV increased during treatment, possibly due to radiation-induced inflammation. Therefore, it is unlikely that (18)F-FDG PET during SBRT will predict treatment success

    Comparison of CT and PET-CT based planning of radiation therapy in locally advanced pancreatic carcinoma

    Get PDF
    Abstract Background To compare computed tomography (CT) with co-registered positron emission tomography-computed tomography (PET-CT) as the basis for delineating gross tumor volume (GTV) in unresectable, locally advanced pancreatic carcinoma (LAPC). Methods Fourteen patients with unresectable LAPC had both CT and PET images acquired. For each patient, two three-dimensional conformal plans were made using the CT and PET-CT fusion data sets. We analyzed differences in treatment plans and doses of radiation to primary tumors and critical organs. Results Changes in GTV delineation were necessary in 5 patients based on PET-CT information. In these patients, the average increase in GTV was 29.7%, due to the incorporation of additional lymph node metastases and extension of the primary tumor beyond that defined by CT. For all patients, the GTVCT versus GTVPET-CT was 92.5 ± 32.3 cm3 versus 104.5 ± 32.6 cm3 (p = 0.009). Toxicity analysis revealed no clinically significant differences between two plans with regard to doses to critical organs. Conclusion Co-registration of PET and CT information in unresectable LAPC may improve the delineation of GTV and theoretically reduce the likelihood of geographic misses.</p

    PET imaging of hypoxia using [F-18]HX4: a phase I trial

    Get PDF
     Download the images using these instructions and this DOI : 10.1007/s00259-010-1437-x Background and purposeNon-invasive PET imaging of tumour hypoxia could help in the selection of those patients who could benefit from chemotherapy or radiation with specific antihypoxic treatments such as bioreductive drugs or hypoxic radiosensitizers. In this phase I trial, we aimed to determine the toxicity of [18F]HX4, a member of the 2-nitroimidazole family, at different dose levels. The secondary aim was to analyse image quality related to the HX4 dose and the timing of imaging.MethodsPatients with a..
    corecore