16 research outputs found

    Efficacy of anatomical prostheses in primary glenohumeral osteoarthritis

    No full text
    More than 32.8% of the over-60s suffer from shoulder osteoarthritis. For advanced osteoarthritis, arthroplasty is the treatment of choice. Current systems have moved on from the first shoulder prosthesis implanted by Neer in 1974, thanks to the use of adaptable modular systems. The aim of this study was to investigate the effectiveness of anatomical shoulder replacements in 30 cases of primary glenohumeral osteoarthritis through clinical and radiographic follow-up for a mean of 5 years. All implants were total cemented prostheses. Preoperative investigations included a clinical examination, conventional X-rays and CT. The Constant-Murley scale was used to evaluate the results; the mean score increased from 21.4 preoperative to 69.8 postoperative (p<0.05). In patients aged under 50, the increase in the mean postoperative Constant Score and ROM was greater than for the sample as a whole. The following complications were encountered: 2 postoperative radial nerve paralyses, resolving in 3 months, 2 cases of glenoid loosening, 1 periprosthetic fracture and 3 cases of pain and stiffness. The results led us to conclude that anatomical prostheses are effective in the treatment of severe primary glenohumeral arthropathy

    Mendelian cytogenetics. Chromosome rearrangements associated with mendelian disorders.

    No full text

    The magnetized steel and scintillator calorimeters of the MINOS experiment

    No full text
    The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the &quot;atmospheric neutrino&quot; sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab&apos;s NuMI neutrino beam with a near detector at Fermilab and again 735 km downstream with a far detector in the Soudan Underground Laboratory in northern Minnesota. The two detectors are magnetized steel-scintillator tracking calorimeters. They are designed to be as similar as possible in order to ensure that differences in detector response have minimal impact on the comparisons of event rates, energy spectra and topologies that are essential to MINOS measurements of oscillation parameters. The design, construction, calibration and performance of the far and near detectors are described in this paper. © 2008 Elsevier B.V

    Biochemistry of hyperthyroidism and hypothyroidism

    No full text
    corecore