598 research outputs found

    Modelling the Impact of Compulsory FMD Insurance

    Get PDF
    This paper compares two ways of financing the combating of Foot and Mouth Disease (FMD) in the EU and uses a simulation model to determine the welfare and production implications of the two systems. The two systems analysed are (i) financing by the tax payers, resembling the system currently in place, and (ii) a compulsory insurance scheme where all costs are converted into regionally differentiated insurance premiums that are paid by the producers. The analysis indicates that welfare gains may be realised by shifting from the former to the latter financing system.foot and mouth disease, insurance scheme, Risk and Uncertainty, D61, Q18,

    Primary breast cancer tumours contain high amounts of IgA1 immunoglobulin:an immunohistochemical analysis of a possible carrier of the tumour-associated Tn antigen

    Get PDF
    The Tn antigen (GalNAc alpha-O-Ser/Thr) as defined by the binding of the lectin, helix pomatia agglutinin (HPA) or anti-Tn monoclonal antibodies, is known to be exposed in a majority of cancers, and it has also been shown to correlate positively with the metastatic capacity in breast carcinoma. The short O-glycan that forms the antigen is carried by a number of different proteins. One potential carrier of the Tn antigen is immunoglobulin A1 (IgA1), which we surprisingly found in tumour cells of the invasive parts of primary breast carcinoma. Conventional immunohistochemical analysis of paraffin-embedded sections from primary breast cancers showed IgA1 to be present in the cytoplasm and plasma membrane of 35 out of 36 individual primary tumours. The immunohistochemical staining of HPA and anti-Tn antibody (GOD3-2C4) did to some extent overlap with the presence of IgA1 in the tumours, but differences were seen in the percentage of stained cells and in the staining pattern in the different breast cancers analysed. Anti-Tn antibody and HPA were also shown to specifically bind to a number of possible constellations of the Tn antigen in the hinge region of IgA1. Both reagents could also detect the presence of Tn positive IgA in serum. On average 51% of the tumour cells in the individual breast cancer tumour sections showed staining for IgA1. The overall amount of staining in the invasive part of the tumour with the anti Tn antibody was 67%, and 93% with HPA. The intra-expression or uptake of IgA1 in breast cancer makes it a new potential carrier of the tumour associated and immunogenic Tn antigen

    Can investments in manure technology reduce nutrient leakage to the Baltic Sea?

    Get PDF
    In this study, quantitative models of the agricultural sector and nutrient transport and cycling are used to analyse the impacts in the Baltic Sea of replacing the current Greening measures of the EU’s Common Agricultural Policy with a package of investments in manure handling. The investments aim at improving nutrient utilization and reducing nitrogen leaching, based on the assumption that lagging farms and regions can catch up with observed good practice. Our results indicate that such investments could reduce nitrogen surpluses in agriculture by 18% and nitrogen concentrations in the Baltic Sea by 1 to 9% depending on the basin. The Greening measures, in contrast, are found to actually increase nitrogen leaching.Peer reviewe

    Health-related quality of life, utility, and productivity outcomes instruments: ease of completion by subjects with COPD

    Get PDF
    An important outcome of any clinical intervention is the change in the subject's own perceived state of health. This can be categorized as health-related quality of life (HRQL), utility (preference-based health state), and daily life performance. 174 Swedish subjects with chronic obstructive pulmonary disease (COPD) (mean age 64.3 ± 12 years) completed five self-administered questionnaires: Short Form 36 (SF-36), St George's Respiratory Questionnaire (SGRQ), EuroQol-5D (EQ-5D), Health States-COPD (HS-COPD), and Work Productivity and Activity Impairment Questionnaire for COPD (WPAI-COPD). The subjects scored these outcomes instruments for ease of completion using a 5-point scale. The time taken to complete them was noted and the administrators' opinion of the subjects' comprehension of the questionnaires recorded using a 4-point scale. A score of 1–3 ("very easy" to "acceptable") was recorded by 92% of subjects for the SF-36, 90% for SGRQ, 80% for EQ-5D, 83% for WPAI-COPD, and 53% for HS-COPD. The HS-COPD was graded "very difficult" to complete by 21% of subjects compared with 3–5% of subjects for the other questionnaires. The mean time taken to complete all questionnaires was 39 minutes, and the large majority of subjects scored "good" for understanding by the administrator. Age correlated significantly with the degree of the subject's opinion of the ease of completion of five outcomes instruments, while the influence of gender, socio-economic status and disease severity was not statistically significant

    Bone Conduction Stimulated VEMP Using the B250 Transducer

    Get PDF
    Objective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation.Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone.Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ.Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones

    Ankle Audiometry: A Clinical Test for the Enhanced Hearing Sensitivity for Body Sounds in Superior Canal Dehiscence Syndrome

    Get PDF
    Introduction: The aim of this study was to develop a clinical test for body sounds\u27 hypersensitivity in superior canal dehiscence syndrome (SCDS). Method: Case-control study, 20 patients affected by SCDS and body sounds\u27 hypersensitivity and 20 control matched subjects tested with a new test called ankle audiometry (AA). The AA consisted of a psychoacoustic hearing test in which the stimulus was substituted by a controlled bone vibration at 125, 250, 500, and 750 Hz, delivered at the medial malleolus by a steel spring-attached bone transducer prototype B250. For each subject, it was defined an index side (the other being non-index), the one with major symptoms in cases or best threshold for each tested frequency in controls. In 3 patients, the AA was measured before and after SCDS surgery. Results: The AA thresholds for index side were significantly lower in SCDS patients (115.6 \ub1 10.5 dB force level [FL]) than in control subjects (126.4 \ub1 8.56 dB FL). In particular, the largest difference was observed at 250 Hz (-16.5 dB). AA thresholds in patients were significantly lower at index side in comparison with non-index side (124.2 \ub1 11.4 dB FL). The response obtained with 250 Hz stimuli outperformed the other frequencies, in terms of diagnostic accuracy for SCDS. At specific thresholds\u27 levels (120 dB FL), AA showed relevant sensitivity (90%) and specificity (80%) for SCDS. AA did not significantly correlate to other clinical markers of SCDS such as the bone and air conducted hearing thresholds and the vestibular evoked myogenic potentials. The AA thresholds were significantly modified by surgical intervention, passing from 119.2 \ub1 9.7 to 130.4 \ub1 9.4 dB FL in 3 patients, following their relief in body sounds\u27 hypersensitivity. Conclusion: AA showed interesting diagnostic features in SCDS with significantly lower hearing thresholds in SCDS patients when compared to healthy matched subjects. Moreover, AA could identify the affected or more affected side in SCDS patients, with a significant threshold elevation after SCDS surgery, corresponding in body sounds\u27 hypersensitivity relief. Clinically, AA may represent a first objective measure of body sounds\u27 hypersensitivity in SCDS and, accordingly, be an accessible screening test for SCDS in not tertiary audiological centers

    Long-term follow-up and review of the Bone Conduction Implant

    Get PDF
    Active transcutaneous bone conduction devices are a type of bone conduction device developed to keep the skin intact and provide direct bone conduction stimulation. The Bone Conduction Implant (BCI) is such a device and has been implanted in 16 patients. The objective of this paper is to give a broad overview of the BCI development to the final results of 13 patients at 5-year follow-up. Follow-up of these patients included audiological performance investigations, questionnaires, as well as safety evaluation and objective functionality testing of the device. Among those audiological measure-ments were sound field warble tone thresholds, speech recognition threshold (SRT), speech recognition score (SRS) and signal to noise ratio threshold (SNR-threshold).The accumulated implant time for all 16 patients was 113 years in February 2022. During this time, no serious adverse events have occurred. The functional improvement for the 13 patients reported in this paper was on average 29.5 dB (average over 0.5, 1, 2 and 4 kHz), while the corresponding effective gain was-12.4 dB. The SRT improvement was 24.5 dB and the SRS improvement was 38.1%, while the aided SNR-threshold was on average -6.4 dB.It was found that the BCI can give effective and safe hearing rehabilitation for patients with conduc-tive and mild-to-moderate mixed hearing loss

    Health-related quality of life is related to COPD disease severity

    Get PDF
    BACKGROUND: The aim of this study was to evaluate the association between health-related quality of life (HRQL) and disease severity using lung function measures. METHODS: A survey was performed in subjects with COPD in Sweden. 168 subjects (70 women, mean age 64.3 years) completed the generic HRQL questionnaire, the Short Form 36 (SF-36), the disease-specific HRQL questionnaire; the St George's Respiratory Questionnaire (SGRQ), and the utility measure, the EQ-5D. The subjects were divided into four severity groups according to FEV(1 )per cent of predicted normal using two clinical guidelines: GOLD and BTS. Age, gender, smoking status and socio-economic group were regarded as confounders. RESULTS: The COPD severity grades affected the SGRQ Total scores, varying from 25 to 53 (GOLD p = 0.0005) and from 25 to 45 (BTS p = 0.0023). The scores for SF-36 Physical were significantly associated with COPD severity (GOLD p = 0.0059, BTS p = 0.032). No significant association were noticed for the SF-36, Mental Component Summary scores and COPD severity. Scores for EQ-5D VAS varied from 73 to 37 (GOLD I-IV p = 0.0001) and from 73 to 50 (BTS 0-III p = 0.0007). The SGRQ Total score was significant between age groups (p = 0.0047). No significant differences in HRQL with regard to gender, smoking status or socio-economic group were noticed. CONCLUSION: The results show that HRQL in COPD deteriorates with disease severity and with age. These data show a relationship between HRQL and disease severity obtained by lung function

    Effect of transducer attachment on vibration transmission and transcranial attenuation for direct drive bone conduction stimulation

    Get PDF
    Direct drive bone conduction devices (BCDs) are used to rehabilitate patients with conductive or mixed hearing loss by stimulating the skull bone directly, either with an implanted transducer (active transcutaneous BCDs), or through a skin penetrating abutment rigidly coupled to an external vibrating transducer (percutaneous BCDs). Active transcutaneous BCDs have been under development to overcome limitations of the percutaneous bone anchored hearing aid (BAHA), mainly related to the skin penetration. The attachment of a direct drive BCD to the skull bone can differ significantly between devices, and possibly influence the vibrations\u27 transmission to the cochleae. In this study, four different attachments are considered: (A) small-sized flat surface, (B) extended flat surface, (C) bar with a screw at both ends, and (D) standard bone anchored hearing aid screw. A, B, and C represent three active transcutaneous options, while D is for percutaneous applications. The primary aim of this study was to investigate how the different transcutaneous attachments (A, B, and C) affect the transmission of vibrations to the cochleae to the ipsilateral and the contralateral side. A secondary aim was to evaluate and compare transcranial attenuation (TA, ipsilateral minus contralateral signal level) between transcutaneous (A, B, and C) and percutaneous attachments (D). Measurements were performed on four human heads, measuring cochlear promontory velocity with a LDV (laser Doppler vibrometer) and sound pressure in the ear canal (ECSP) with an inserted microphone. The stimulation signal was a swept sine between 0.1 and 10 kHz. The comparison of ipsilateral transmission between transcutaneous adaptors A, B, and C was in agreement with previous findings, confirming that: (1) Adaptor C seems to give the most effective transmission for frequencies around 6 kHz but somewhat lower in the mid frequency range, and (2) keeping a smaller contact area seems to provide advantages compared to a more extended one. The same trends were seen ipsilaterally and contralaterally. The observed TA was similar for adaptors A, B, and C at the mastoid position, ranging -10-0 dB below 500 Hz, and 10-20 dB above. A lower TA was seen above 500 Hz when using adaptor D at the parietal position
    • …
    corecore