10 research outputs found

    Interpenetrating Polymer Networks as Binders for Solid Composite Propellants

    Get PDF
    A new family of polymeric binders for solid composite propellants is proposed, based on two component interpenetrating polymer networks (IPNs). These networks comprise two different polyurethanes based on hydroxy terminated polybutadiene and ISRO polyol interpenetrated with two different vinyl polymers, viz poly methyl methacrylate and polystyrene. the networks synthesized by the simultaneous interpenetrating technique have been characterized for their properties, such as stress-strain, density, viscosity, thermal degradation, and heat of combustion. Phase morphologies have been determined using electron microscopy. Suitable explanations have been adduced to rationalize the properties of IPNs in terms of their structures and chain interactions. A study of the mechanical properties and burning rates of the ammonium perchlorate (AP)-based solid propellant using the newly synthesised IPNs as binders, has been carried out. The results show that both mechanical strength and burning rate of solid propellants could be suitably modified by simply changing the nature and/or the ratio of the two interpenetrating polymer components

    Trends and transitions in the institutional environment for public and private science

    Full text link
    The last quarter-century bore witness to a sea change in academic involvement with commerce. Widespread university-based efforts to identify, manage, and market intellectual property (IP) have accompanied broad shifts in the relationship between academic and proprietary approaches to the dissemination and use of science and engineering research. Such transformations are indicators of institutional changes at work in the environment faced by universities. This paper draws upon a fifteen-year panel (1981–1995) of university-level data for 87 research-intensive US campuses in order to document trends and transitions in relationships among multiple indicators of academic and commercial engagement. The institutional environment for public and private science is volatile, shifting in fits and starts from a situation conducive to organizational learning through high volume patenting to a more challenging arrangement that links indiscriminate pursuit of IP with declines in both the volume and impact of academic science. The pattern and timing of these transitions may support an enduring system of stratification that offers increasing returns to first-movers while limiting the opportunities available to universities that are later entrants to the commercial realm. Unpacking the systematic effects of university research commercialization requires focused attention on the sources and trajectories of profound institutional change.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42839/1/10734_2004_Article_2916.pd

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    The impact of the International Nosocomial Infection Control Consortium (INICC) multicenter, multidimensional hand hygiene approach in two cities of India

    Get PDF
    The fundamental tool for preventing and controlling healthcare-acquired infections is hand hygiene (HH). Nonetheless, adherence to HH guidelines is often low. Our goal was to assess the effect of the International Nosocomial Infection Control Consortium (INICC) Multidimensional Hand Hygiene Approach (IMHHA) in three intensive care units of three INICC member hospitals in two cities of India and to analyze the predictors of compliance with HH. From August 2004 to July 2011, we carried out an observational, prospective, interventional study to evaluate the implementation of the IMHHA, which included the following elements: (1) administrative support, (2) supplies availability, (3) education and training, (4) reminders in the workplace, (5) process surveillance and (6) performance feedback. The practices of health care workers were monitored during randomly selected 30-min periods. We observed 3612 opportunities for HH. Overall adherence to HH increased from 36.9% to 82% (95% CI 79.3–84.5; P=0.0001). Multivariate analysis indicated that certain variables were significantly associated with poor HH adherence: nurses vs. physicians (70.5% vs. 74%; 95% CI 0.62–0.96; P=0.018), ancillary staff vs. physicians (43.6% vs. 74.0%; 95% CI 0.48–0.72; P<0.001), ancillary staff vs. nurses (43.6% vs. 70.5%; 95% CI 0.51–0.75; P<0.001) and private vs. academic hospitals (74.2% vs. 66.3%; 95% CI 0.83–0.97; P<0.001). It is worth noticing that in India, the HH compliance of physicians is higher than in nurses. Adherence to HH was significantly increased by implementing the IMHHA. Programs targeted at improving HH are warranted to identify predictors of poor compliance

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN
    corecore