5,682 research outputs found
Progress with diamond over-coated microstrip gas chambers
We describe recent observations and measurements with Micro-Strip Gas Chambers coated, after manufacturing, with a thin diamond-like layer in order to increase their rate capability. Compared to the more widely used solution consisting in coating the insulating support with a conductive layer before photo-lithography (the so-called undercoating), over-coating has the advantage of avoiding possible problems with adherence of metals to the layer, damages during the etching process and reduced quality of the artwork resulting from imperfections or dust inclusions in the layer. Early tests have however indicated that, possibly because of damages to the layer due to electron and ion bombardment during the avalanche process, irreversible structural modifications and fatal breakdown could be encountered at very high integral radiation fluxes. The present paper summarizes these results, and describes recent developments demonstrating that a better choice of the parameters of the over-coat may allow to withstand the radiation doses anticipated for LHC detectors with the intrinsically simpler over-coating solution. We discuss also several possible applications of the use of thin, controlled resistivity layers for other families of detectors used or in development for CERN¹s high luminosity collider
Operation of high rate microstrip gas chambers
We describe recent measurements carried out in well controlled and reproducible conditions to help understanding the factors affecting the short and long term behaviour of Microstrip Gas Chambers. Special care has been taken concerning the gas purity and choice of materials used in the system and for the detectors construction. Detectors built on glasses with surface resistivity in the range have shown satisfactory performance as they do not show charging-up process at high rate and stand the large doses required for the future high luminosity experiments (~10 mC·cm-1·yr-1). Concerning the lifetime measurements, it has been observed that chambers manufactured on high-resistivity glass are far more susceptible of suffering ageing than detectors made on low resistivity, electron-conducting supports, independently of the metal used for the artwork (chromium or gold) at least in clean gas conditions. The successfully operation in the laboratory of detectors manufactured on diamond-coated glass with a surface resistivity around confirms the last statement. Results from a long-term, high rate beam test are also reported
Operation of microstrip gas chambers manufactured on glass coated with high resistivity diamond-like layers
We describe recent observations and measurements realized with micro-strip gas chambers (MSGCs) manufactured on boro-silicate glass coated with a thin layer of diamond-like carbon (DLC) having a surface resistivity around 4.10. The role of the back-pla electrode configuration and potential in the detector performance has been studied. Even for this very high resistivity of the coatings, MSGCs operate differently from those manufactured on bare boro-silicate glass; the charge gain increases with the radiation flux for counting rates above 103 Hz/mm2, reaching a value 60% higher for 105 Hz/mm2. This behavior does not depend on the presence and potential of the back plane electrode; however, both maximum gain and rate capability are influenced by the drift field. From this study, compared with measurements realized previously with other detectors, we deduce that for stable high rate operation of MSGCs the resistivity of the coating should not exceed ~10
Study of ageing and gain limits of microstrip gas chambers at high rates
The CMS experiment comprises MSGCs as one of the key detection elements for high luminosity tracking at LHC. In addition to the high dose rate of 10 mC/year per cm of strip, these detectors have to survive the hostile presence of highly ionizing particles, neutrons low energy gammas and hadrons. In this report we present the results of systematic tests on maximum safe operational gain limits in MSGCs before the discharge. Long term ageing tests performed on prototype open Ibanana¹ modules envisaged to be arranged around the interaction region in the forward part of the CMS tracker show no evidence of gain drop up to equivalent ~ 10 years of LHC operation. A comparison is made between argon and neon gas mixtures with DME in equal proportions by investigating long term irradiation effects on chamber operation by introducing controlled and reproducible pollution in the gas lines
"Diamond" over-coated Microstrip Gas Chambers for high rate operation
We describe the recent developments on the diamond-like carbon (DLC) over-coated Microstrip Gas Chambers made on drawn glass substrates. MSGC surface coating with thin DLC layer of stable and controlled resistivity was proposed to overcome the limitation of detector operation due to surface charging-up under avalanches. This brings also advantages for the detector manufacturing technology. The thin layer, deposited on top of a manufactured MSGC (over-coating), demonstrates excellent mechanical properties and very good stability. We report on recent measurements with DLC over-coated MSGCs of various surface resistivities (ranging from 1013W/r to 1016W/r) on D-263 and AF45 glass substrates. Over-coated MSGCs exhibit good rate capability for the resistivity of the surface around 1015W/r. Stable operation up to 50 mC/cm of accumulated charge from avalanches has been demonstrated
Search for the QCD critical point in nuclear collisions at the CERN SPS
Pion production in nuclear collisions at the SPS is investigated with the aim
to search, in a restricted domain of the phase diagram, for power-laws in the
behavior of correlations which are compatible with critical QCD. We have
analyzed interactions of nuclei of different size (p+p, C+C, Si+Si, Pb+Pb) at
158 GeV adopting, as appropriate observables, scaled factorial moments in a
search for intermittent fluctuations in transverse dimensions. The analysis is
performed for pairs with invariant mass very close to the two-pion
threshold. In this sector one may capture critical fluctuations of the sigma
component in a hadronic medium, even if the -meson has no well defined
vacuum state. It turns out that for the Pb+Pb system the proposed analysis
technique cannot be applied without entering the invariant mass region with
strong Coulomb correlations. As a result the treatment becomes inconclusive in
this case. Our results for the other systems indicate the presence of power-law
fluctuations in the freeze-out state of Si+Si approaching in size the
prediction of critical QCD.Comment: 31 pages, 11 figure
Inclusive production of charged pions in p+C collisions at 158 GeV/c beam momentum
The production of charged pions in minimum bias p+C interactions is studied
using a sample of 377000 inelastic events obtained with the NA49 detector at
the CERN SPS at 158 GeV/c beam momentum. The data cover a phase space area
ranging from 0 to 1.8 GeV/c in transverse momentum and from -0.1 to 0.5 in
Feynman x. Inclusive invariant cross sections are given on a grid of 270 bins
per charge thus offering for the first time a dense coverage of the projectile
hemisphere and of the cross-over region into the target fragmentation zone.Comment: 31 pages, 30 figures, submitted to European Journal of Physic
System-size and centrality dependence of charged kaon and pion production in nucleus-nucleus collisions at 40A GeV and158A GeV beam energy
Measurements of charged pion and kaon production are presented in centrality
selected Pb+Pb collisions at 40A GeV and 158A GeV beam energy as well as in
semi-central C+C and Si+Si interactions at 40A GeV. Transverse mass spectra,
rapidity spectra and total yields are determined as a function of centrality.
The system-size and centrality dependence of relative strangeness production in
nucleus-nucleus collisions at 40A GeV and 158A GeV beam energy are derived from
the data presented here and published data for C+C and Si+Si collisions at 158A
GeV beam energy. At both energies a steep increase with centrality is observed
for small systems followed by a weak rise or even saturation for higher
centralities. This behavior is compared to calculations using transport models
(UrQMD and HSD), a percolation model and the core-corona approach.Comment: 32 pages, 14 figures, 4 tables, typo table II correcte
Rapidity and energy dependence of the electric charge correlations in A+A collisions at the SPS energies
Results from electric charge correlations studied with the Balance Function
method in A+A collisions from 20\emph{A} to 158\emph{A} GeV are presented in
two different rapidity intervals: In the mid-rapidity region we observe a
decrease of the width of the Balance Function distribution with increasing
centrality of the collision, whereas this effect vanishes in the forward
rapidity region.
Results from the energy dependence study in central Pb+Pb collisions show
that the narrowing of the Balance Function expressed by the normalised width
parameter \textit{W} increases with energy towards the highest SPS and RHIC
energies.
Finally we compare our experimental data points with predictions of several
models. The hadronic string models UrQMD and HIJING do not reproduce the
observed narrowing of the Balance Function. However, AMPT which contains a
quark-parton transport phase before hadronization can reproduce the narrowing
of the BF's width with centrality. This confirms the proposed sensitivity of
the Balance Function analysis to the time of hadronization.Comment: Submitted in Phys. Rev.
Measurement of event-by-event transverse momentum and multiplicity fluctuations using strongly intensive measures and in nucleus-nucleus collisions at the CERN Super Proton Synchrotron
Results from the NA49 experiment at the CERN SPS are presented on
event-by-event transverse momentum and multiplicity fluctuations of charged
particles, produced at forward rapidities in central Pb+Pb interactions at beam
momenta 20, 30, 40, 80, and 158 GeV/c, as well as in systems of
different size (, C+C, Si+Si, and Pb+Pb) at 158 GeV/c. This publication
extends the previous NA49 measurements of the strongly intensive measure
by a study of the recently proposed strongly intensive measures of
fluctuations and . In the explored kinematic
region transverse momentum and multiplicity fluctuations show no significant
energy dependence in the SPS energy range. However, a remarkable system size
dependence is observed for both and , with the
largest values measured in peripheral Pb+Pb interactions. The results are
compared with NA61/SHINE measurements in collisions, as well as with
predictions of the UrQMD and EPOS models.Comment: 12 pages, 14 figures, to be submitted to PR
- …