43 research outputs found
Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm(3 )ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans
Saudi SCD patients’ symptoms and quality of life relative to the number of ED visits
Background Individuals living with sickle cell disease (SCD) have significantly increased emergency department (ED) use compared to the general population. In Saudi Arabia, health care is free for all individuals and therefore has no bearing on increased ED visits. However, little is known about the relationship between quality of life (QoL) and frequency of acute care utilization in this patient population. Methods A cross-sectional study was conducted on 366 patients with SCD who attended the outpatient department at King Fahad Hospital, Hofuf, Saudi Arabia. Data were collected through self-administered surveys, which included: demographics, SCD-related ED visits, clinical issues, and QoL levels. We assessed the ED use by asking for the number of SCD-related ED visits within a 6-month period. Results The self-report survey of ED visits was completed by 308 SCD patients. The median number of SCD-related ED visits within a 6-month time period (IQR) was four (2-7 visits). According to the unadjusted negative binomial model, the rate of SCD-related ED visits increased by (46, 39.3, 40, and 53.5 %) for patients with fever, skin redness with itching, swelling, and blood transfusion, respectively. Poor QoL tends to increase the rate of SCD-related ED visits. Well education and poor general health positively influenced the rate of SCD-related ED visits. Well education tends to increase the rate of SCD-related ED visits by 50.2 %. The rate of SCD-related ED visits decreased by 1.4 % for every point increase in general health. Conclusion Saudi patients with sickle cell disease reported a wide range of SCD-related ED visits. It was estimated that six of 10 SCD patients had at least three ED visits within a 6-month period. Well education and poor general health resulted in an increase in the rate of SCD-related ED visits
What is the value and impact of quality and safety teams? A scoping review
<p>Abstract</p> <p>Background</p> <p>The purpose of this study was to conduct a scoping review of the literature about the establishment and impact of quality and safety team initiatives in acute care.</p> <p>Methods</p> <p>Studies were identified through electronic searches of Medline, Embase, CINAHL, PsycINFO, ABI Inform, Cochrane databases. Grey literature and bibliographies were also searched. Qualitative or quantitative studies that occurred in acute care, describing how quality and safety teams were established or implemented, the impact of teams, or the barriers and/or facilitators of teams were included. Two reviewers independently extracted data on study design, sample, interventions, and outcomes. Quality assessment of full text articles was done independently by two reviewers. Studies were categorized according to dimensions of quality.</p> <p>Results</p> <p>Of 6,674 articles identified, 99 were included in the study. The heterogeneity of studies and results reported precluded quantitative data analyses. Findings revealed limited information about attributes of successful and unsuccessful team initiatives, barriers and facilitators to team initiatives, unique or combined contribution of selected interventions, or how to effectively establish these teams.</p> <p>Conclusions</p> <p>Not unlike systematic reviews of quality improvement collaboratives, this broad review revealed that while teams reported a number of positive results, there are many methodological issues. This study is unique in utilizing traditional quality assessment and more novel methods of quality assessment and reporting of results (SQUIRE) to appraise studies. Rigorous design, evaluation, and reporting of quality and safety team initiatives are required.</p
MR fluoroscopy in vascular and cardiac interventions (review)
Vascular and cardiac disease remains a leading cause of morbidity and mortality in developed and emerging countries. Vascular and cardiac interventions require extensive fluoroscopic guidance to navigate endovascular catheters. X-ray fluoroscopy is considered the current modality for real time imaging. It provides excellent spatial and temporal resolution, but is limited by exposure of patients and staff to ionizing radiation, poor soft tissue characterization and lack of quantitative physiologic information. MR fluoroscopy has been introduced with substantial progress during the last decade. Clinical and experimental studies performed under MR fluoroscopy have indicated the suitability of this modality for: delivery of ASD closure, aortic valves, and endovascular stents (aortic, carotid, iliac, renal arteries, inferior vena cava). It aids in performing ablation, creation of hepatic shunts and local delivery of therapies. Development of more MR compatible equipment and devices will widen the applications of MR-guided procedures. At post-intervention, MR imaging aids in assessing the efficacy of therapies, success of interventions. It also provides information on vascular flow and cardiac morphology, function, perfusion and viability. MR fluoroscopy has the potential to form the basis for minimally invasive image–guided surgeries that offer improved patient management and cost effectiveness
Qualitative and Quantitative Guides to the Selection and Arrangement of the Maxillary Anterior Teeth
Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
At pediatric chest CT, radiation dose and cancer risk, when normalized by tube current–time product, volume-weighted CT dose index, or dose–length product (DLP), decreased exponentially with increasing patient chest diameter; when normalized by DLP, effective dose and cancer risk were independent of beam collimation, helical pitch, and tube potential