78 research outputs found

    The influence of skeletal muscle anisotropy on electroporation: in vivo study and numerical modeling

    Get PDF
    The aim of this study was to theoretically and experimentally investigate electroporation of mouse tibialis cranialis and to determine the reversible electroporation threshold values needed for parallel and perpendicular orientation of the applied electric field with respect to the muscle fibers. Our study was based on local electric field calculated with three-dimensional realistic numerical models, that we built, and in vivo visualization of electroporated muscle tissue. We established that electroporation of muscle cells in tissue depends on the orientation of the applied electric field; the local electric field threshold values were determined (pulse parameters: 8 × 100 μs, 1 Hz) to be 80 V/cm and 200 V/cm for parallel and perpendicular orientation, respectively. Our results could be useful electric field parameters in the control of skeletal muscle electroporation, which can be used in treatment planning of electroporation based therapies such as gene therapy, genetic vaccination, and electrochemotherapy

    Ventilation-perfusion inequality in the human lung is not increased following no-decompression-stop hyperbaric exposure

    Get PDF
    Venous gas bubbles occur in recreational SCUBA divers in the absence of decompression sickness, forming venous gas emboli (VGE) which are trapped within pulmonary circulation and cleared by the lung without overt pathology. We hypothesized that asymptomatic VGE would transiently increase ventilation-perfusion mismatch due to their occlusive effects within the pulmonary circulation. Two sets of healthy volunteers (n = 11, n = 12) were recruited to test this hypothesis with a single recreational ocean dive or a baro-equivalent dry hyperbaric dive. Pulmonary studies (intrabreath VA/Q (iV/Q), alveolar dead space, and FVC) were conducted at baseline and repeat 1- and 24-h after the exposure. Contrary to our hypothesis VA/Q mismatch was decreased 1-h post-SCUBA dive (iV/Q slope 0.023 ± 0.008 ml−1 at baseline vs. 0.010 ± 0.005 NS), and was significantly reduced 24-h post-SCUBA dive (0.000 ± 0.005, p < 0.05), with improved VA/Q homogeneity inversely correlated to dive severity. No changes in VA/Q mismatch were observed after the chamber dive. Alveolar dead space decreased 24-h post-SCUBA dive (78 ± 10 ml at baseline vs. 56 ± 5, p < 0.05), but not 1-h post dive. FVC rose 1-h post-SCUBA dive (5.01 ± 0.18 l vs. 5.21 ± 0.26, p < 0.05), remained elevated 24-h post SCUBA dive (5.06 ± 0.2, p < 0.05), but was decreased 1-hr after the chamber dive (4.96 ± 0.31 L to 4.87 ± 0.32, p < 0.05). The degree of VA/Q mismatch in the lung was decreased following recreational ocean dives, and was unchanged following an equivalent air chamber dive, arguing against an impact of VGE on the pulmonary circulation

    Transmembrane potential induced on the internal organelle by a time-varying magnetic field: a model study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>When a cell is exposed to a time-varying magnetic field, this leads to an induced voltage on the cytoplasmic membrane, as well as on the membranes of the internal organelles, such as mitochondria. These potential changes in the organelles could have a significant impact on their functionality. However, a quantitative analysis on the magnetically-induced membrane potential on the internal organelles has not been performed.</p> <p>Methods</p> <p>Using a two-shell model, we provided the first analytical solution for the transmembrane potential in the organelle membrane induced by a time-varying magnetic field. We then analyzed factors that impact on the polarization of the organelle, including the frequency of the magnetic field, the presence of the outer cytoplasmic membrane, and electrical and geometrical parameters of the cytoplasmic membrane and the organelle membrane.</p> <p>Results</p> <p>The amount of polarization in the organelle was less than its counterpart in the cytoplasmic membrane. This was largely due to the presence of the cell membrane, which "shielded" the internal organelle from excessive polarization by the field. Organelle polarization was largely dependent on the frequency of the magnetic field, and its polarization was not significant under the low frequency band used for transcranial magnetic stimulation (TMS). Both the properties of the cytoplasmic and the organelle membranes affect the polarization of the internal organelle in a frequency-dependent manner.</p> <p>Conclusions</p> <p>The work provided a theoretical framework and insights into factors affecting mitochondrial function under time-varying magnetic stimulation, and provided evidence that TMS does not affect normal mitochondrial functionality by altering its membrane potential.</p

    Simultaneous Occupational Exposure to FM and UHF Transmitters

    No full text
    Occupational exposure caused by large broadcasting transmitters exceeds current reference levels. As it is common for different radio and TV transmitters to share the location, we analysed combined exposure on a 40-m high mast. The frequency modulation (FM) transmitter, located between the 10th and 30th metre, had the power of 25 kW, whereas an ultra-high frequency (UHF) transmitter of 5 kW occupied the top 8 m of the mast. Measured and calculated values of the electric field strength exceeded the reference levels up to 10 times; however, the results for the specific absorption rate (SAR) values show that the reference levels are very conservative for FM exposure, i.e., basic restrictions are not exceeded even when the reference levels are exceeded 10 times. However, for UHF exposure the reference levels are not conservative; they give a good prediction of real exposure

    Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values

    No full text
    Electric field strengths normally exceed the reference levels for occupational exposure in close vicinity to large frequency modulation (FM) transmitters. Thus, a detailed investigation on compliance with basic restrictions is needed before any administrative protection measures are applied. We prepared a detailed numerical model of a 20-kW FM transmitter on a 32-m mast. An electrically isolated anatomical human model was placed in 3 different positions inside the mast in the region where the values of the electric field were highest. The electric field strengths in this region were up to 700 V/m. The highest calculated whole-body specific absorption rate (SAR) was 0.48 W/kg, whereas the maximum 10-g average SAR in the head and trunk was 1.66 W/kg. The results show that the reference levels in the FM frequency range are very conservative for near field exposure. SAR values are not exceeded even for fields 10 times stronger than the reference levels

    Assessment of Mercury Air Concentrations in a Work Environment

    Full text link
    corecore