30 research outputs found
Selective Vulnerability of the Cochlear Basal Turn to Acrylonitrile and Noise
Exposure to acrylonitrile, a high-production industrial chemical, can promote noise-induced hearing loss (NIHL) in the rat even though this agent does not itself produce permanent hearing loss. The mechanism by which acrylonitrile promotes NIHL includes oxidative stress as antioxidant drugs can partially protect the cochlea from acrylonitrile + noise. Acrylonitrile depletes glutathione levels while noise can increase the formation of reactive oxygen species. It was previously noted that the high-frequency or basal turn of the cochlea was particularly vulnerable to the combined effects of acrylonitrile and noise when the octave band noise (OBN) was centered at 8 kHz. Normally, such a noise would be expected to yield damage at a more apical region of the cochlea. The present study was designed to determine whether the basal cochlea is selectively sensitive to acrylonitrile or whether, by adjusting the frequency of the noise band, it would be possible to control the region of the auditory impairment. Rats were exposed to one of three different OBNs centered at different frequencies (4 kHz, 110 dB and 8 or 16 kHz at 97 dB) for 5 days, with and without administration of acrylonitrile (50 mg/kg/day). The noise was set to cause limited NIHL by itself. Auditory function was monitored by recording distortion products, by compound action potentials, and by performing cochlear histology. While the ACN-only and noise-only exposures induced no or little permanent auditory loss, the three exposures to acrylonitrile + noise produced similar auditory and cochlear impairments above 16 kHz, despite the fact that the noise exposures covered 2 octaves. These observations show that the basal cochlea is much more sensitive to acrylonitrile + noise than the apical partition. They provide an initial basis for distinguishing the pattern of cochlear injury that results from noise exposure from that which occurs due to the combined effects of noise and a chemical contaminant
An in vitro model to assess the peripheral vestibulotoxicity of aromatic solvents.
peer reviewedEpidemiological and experimental studies indicate that a number of aromatic solvents widely used in the industry can affect hearing and balance following chronic exposure. Animal studies demonstrated that long-term exposure to aromatic solvents directly damages the auditory receptor within the inner ear: the cochlea. However, no information is available on their effect on the vestibular receptor, which shares many structural features with the cochlea and is also localized in inner ear. The aim of this study was to use an in vitro approach to assess and compare the vestibular toxicity of different aromatic solvents (toluene, ethylbenzene, styrene and ortho-, meta-, para-xylene), all of which have well known cochleotoxic properties. We used a three-dimensional culture model of rat utricles ("cysts") with preserved functional sensory and secretory epithelia, and containing a potassium-rich (K+) endolymph-like fluid for this study. Variations in K+ concentrations in this model were considered as biomarkers of toxicity of the substances tested. After 72 h exposure, o-xylene, ethylbenzene and styrene decreased the K+ concentration by 78 %, 37 % and 28 %, respectively. O- xylene and styrene both caused histopathological alterations in secretory and sensory epithelial areas after 72 h exposure, whereas no anomalies were observed in ethylbenzene-exposed samples. These in vitro results suggest that some widely used aromatic solvents might have vestibulotoxic properties (o-xylene, styrene and ethylbenzene), whereas others may not (p-xylene, m-xylene, toluene). Our results also indicate that variations in endolymphatic K+ concentration may be a more sensitive marker of vestibular toxicity than histopathological events. Finally, this study suggests that cochleotoxic solvents might not be necessarily vestibulotoxic, and vice versa
Three-dimensional cultured ampullae from rats as a screening tool for vestibulotoxicity: Proof of concept using styrene.
peer reviewedNumerous ototoxic drugs, such as some antibiotics and chemotherapeutics, are both cochleotoxic and vestibulotoxic (causing hearing loss and vestibular disorders). However, the impact of some industrial cochleotoxic compounds on the vestibular receptor, if any, remains unknown. As in vivo studies are long and expensive, there is considerable need for predictive and cost-effective in vitro models to test ototoxicity. Here, we present an organotypic model of cultured ampullae harvested from rat neonates. When cultured in a gelatinous matrix, ampulla explants form an enclosed compartment that progressively fills with a high-potassium (K+) endolymph-like fluid. Morphological analyses confirmed the presence of a number of cell types, sensory epithelium, secretory cells, and canalar cells. Treatments with inhibitors of potassium transporters demonstrated that the potassium homeostasis mechanisms were functional. To assess the potential of this model to reveal the toxic effects of chemicals, explants were exposed for either 2 or 72 h to styrene at a range of concentrations (0.5-1 mM). In the 2-h exposure condition, K+ concentration was significantly reduced, but ATP levels remained stable, and no histological damage was visible. After 72 h exposure, variations in K+ concentration were associated with histological damage and decreased ATP levels. This in vitro 3D neonatal rat ampulla model therefore represents a reliable and rapid means to assess the toxic properties of industrial compounds on this vestibular tissue, and can be used to investigate the specific underlying mechanisms
Styrene alters potassium endolymphatic concentration in a model of cultured utricle explants.
peer reviewedDespite well-documented neurotoxic and ototoxic properties, styrene remains commonly used in industry. Its effects on the cochlea have been extensively studied in animals, and epidemiological and animal evidence indicates an impact on balance. However, its influence on the peripheral vestibular receptor has yet to be investigated. Here, we assessed the vestibulotoxicity of styrene using an in vitro model, consisting of three-dimensional cultured newborn rat utricles filled with a high‑potassium (K+) endolymph-like fluid, called "cysts". K+ entry in the cyst ("influx") and its exit ("efflux") are controlled by secretory cells and hair cells, respectively. The vestibular epithelium's functionality is thus linked to K+ concentration, measured using a microelectrode. Known inhibitors of K+ efflux and influx validated the model. Cysts were subsequently exposed to styrene (0.25; 0.5; 0.75 and 1 mM) for 2 h or 72 h. The decrease in K+ concentration measured after both exposure durations was dose-dependent, and significant from 0.75 mM styrene. Vacuoles were visible in the cytoplasm of epithelial cells from 0.5 mM after 2 h and from 0.25 mM after 72 h. The results presented here are the first evidence that styrene may deregulate K+ homeostasis in the endolymphatic space, thereby altering the functionality of the vestibular receptor
P.1.b.021 Why electroencephalography is a powerful tool to identify translational biomarkers for psychiatric disorders?
The preclinical set-up at the ID17 biomedical beamline to achieve high local dose deposition using interlaced microbeams
International audienceMicrobeam Radiation Therapy (MRT) uses spatially a fractionated "white beam" (energies 50-350 keV) irradiation from a Synchrotron Source. The typical microbeams used at ID17 are 25-100 mu m-thick, spaced by 200-400 mu m, and carry extremely high dose rates (up to about 16 kGy/s). These microbeams are well tolerated by biological tissue, i.e. up to several hundred of Gy in the peaks. When valley doses, caused by Compton scattering in between two microbeams, remain within a dose regime similar to conventional RT, a superior tumour control can be achieved with MRT than with conventional RT. The normal tissue tolerance of these microscopically small beams is outstanding and well documented in the literature. The hypothesis of a differential effect in particular on the vasculature of normal versus tumoral tissue might best be proven by using large animal models with spontaneous tumors instead of small laboratory animals with transplantable tumors, an ongoing project on ID17. An alternative approach to deposit a high dose, while preserving the feature of the spatial separation of these microbeams outside the target has opened up new applications in preclinical research. The instrumentation of this method to produce such interlaced beams is presented with an outlook on the challenges to build a treatment platform for human patients. Dose measurements using Gafchromic films exposed in interlaced geometries with their steep profiles highlight the potential to deposit radiotoxic doses in the vicinity of radiosensitive tissue
