135 research outputs found

    Criminal Procedure Survey

    Get PDF

    Vol. 44, no. 1: Editor\u27s Note

    Get PDF

    Reliability of brain atrophy measurements in multiple sclerosis using MRI: an assessment of six freely available software packages for cross-sectional analyses

    Get PDF
    PURPOSE: Volume measurement using MRI is important to assess brain atrophy in multiple sclerosis (MS). However, differences between scanners, acquisition protocols, and analysis software introduce unwanted variability of volumes. To quantify theses effects, we compared within-scanner repeatability and between-scanner reproducibility of three different MR scanners for six brain segmentation methods. METHODS: Twenty-one people with MS underwent scanning and rescanning on three 3 T MR scanners (GE MR750, Philips Ingenuity, Toshiba Vantage Titan) to obtain 3D T1-weighted images. FreeSurfer, FSL, SAMSEG, FastSurfer, CAT-12, and SynthSeg were used to quantify brain, white matter and (deep) gray matter volumes both from lesion-filled and non-lesion-filled 3D T1-weighted images. We used intra-class correlation coefficient (ICC) to quantify agreement; repeated-measures ANOVA to analyze systematic differences; and variance component analysis to quantify the standard error of measurement (SEM) and smallest detectable change (SDC). RESULTS: For all six software, both between-scanner agreement (ICCs ranging 0.4–1) and within-scanner agreement (ICC range: 0.6–1) were typically good, and good to excellent (ICC > 0.7) for large structures. No clear differences were found between filled and non-filled images. However, gray and white matter volumes did differ systematically between scanners for all software (p < 0.05). Variance component analysis yielded within-scanner SDC ranging from 1.02% (SAMSEG, whole-brain) to 14.55% (FreeSurfer, CSF); and between-scanner SDC ranging from 4.83% (SynthSeg, thalamus) to 29.25% (CAT12, thalamus). CONCLUSION: Volume measurements of brain, GM and WM showed high repeatability, and high reproducibility despite substantial differences between scanners. Smallest detectable change was high, especially between different scanners, which hampers the clinical implementation of atrophy measurements

    Feasibility of detecting atrophy relevant for disability and cognition in multiple sclerosis using 3D-FLAIR

    Get PDF
    BACKGROUND AND OBJECTIVES: Disability and cognitive impairment are known to be related to brain atrophy in multiple sclerosis (MS), but 3D-T1 imaging required for brain volumetrics is often unavailable in clinical protocols, unlike 3D-FLAIR. Here our aim was to investigate whether brain volumes derived from 3D-FLAIR images result in similar associations with disability and cognition in MS as do those derived from 3D-T1 images. METHODS: 3T-MRI scans of 329 MS patients and 76 healthy controls were included in this cross-sectional study. Brain volumes were derived using FreeSurfer on 3D-T1 and compared with brain volumes derived with SynthSeg and SAMSEG on 3D-FLAIR. Relative agreement was evaluated by calculating the intraclass correlation coefficient (ICC) of the 3D-T1 and 3D-FLAIR volumes. Consistency of relations with disability and average cognition was assessed using linear regression, while correcting for age and sex. The findings were corroborated in an independent validation cohort of 125 MS patients. RESULTS: The ICC between volume measured with FreeSurfer and those measured on 3D-FLAIR for brain, ventricle, cortex, total deep gray matter and thalamus was above 0.74 for SAMSEG and above 0.91 for SynthSeg. Worse disability and lower average cognition were similarly associated with brain (adj. R2 = 0.24-0.27, p < 0.01; adj. R2 = 0.26-0.29, p < 0.001) ventricle (adj. R2 = 0.27-0.28, p < 0.001; adj. R2 = 0.19-0.20, p < 0.001) and deep gray matter volumes (adj. R2 = 0.24-0.28, p < 0.001; adj. R2 = 0.27-0.28, p < 0.001) determined with all methods, except for cortical volumes derived from 3D-FLAIR. DISCUSSION: In this cross-sectional study, brain volumes derived from 3D-FLAIR and 3D-T1 show similar relationships to disability and cognitive dysfunction in MS, highlighting the potential of these techniques in clinical datasets

    Measurement of mechanical vibrations excited in aluminium resonators by 0.6 GeV electrons

    Get PDF
    We present measurements of mechanical vibrations induced by 0.6 GeV electrons impinging on cylindrical and spherical aluminium resonators. To monitor the amplitude of the resonator's vibrational modes we used piezoelectric ceramic sensors, calibrated by standard accelerometers. Calculations using the thermo-acoustic conversion model, agree well with the experimental data, as demonstrated by the specific variation of the excitation strengths with the absorbed energy, and with the traversing particles' track positions. For the first longitudinal mode of the cylindrical resonator we measured a conversion factor of 7.4 +- 1.4 nm/J, confirming the model value of 10 nm/J. Also, for the spherical resonator, we found the model values for the L=2 and L=1 mode amplitudes to be consistent with our measurement. We thus have confirmed the applicability of the model, and we note that calculations based on the model have shown that next generation resonant mass gravitational wave detectors can only be expected to reach their intended ultra high sensitivity if they will be shielded by an appreciable amount of rock, where a veto detector can reduce the background of remaining impinging cosmic rays effectively.Comment: Tex-Article with epsfile, 34 pages including 13 figures and 5 tables. To be published in Rev. Scient. Instr., May 200

    Lumbar position sense acuity during an electrical shock stressor

    Get PDF
    BACKGROUND: Optimal motor control of the spine depends on proprioceptive input as a prerequisite for co-ordination and the stability of the spine. Muscle spindles are known to play an important role in proprioception. Animal experiments suggest that an increase in sympathetic outflow can depress muscle spindle sensitivity. As the muscle spindle may be influenced by sympathetic modulation, we hypothesized that a state of high sympathetic activity as during mental stress would affect the proprioceptive output from the muscle spindles in the back muscles leading to alterations in proprioception and position sense acuity. The aim was to investigate the effect of mental stress, in this study the response to an electrical shock stressor, on position sense acuity in the rotational axis of the lumbar spine. METHODS: Passive and active position sense acuity in the rotational plane of the lumbar spine was investigated in the presence and absence of an electrical shock stressor in 14 healthy participants. An electrical shock-threat stressor lasting for approximately 12 minutes was used as imposed stressor to build up a strong anticipatory arousal: The participants were told that they were going to receive 8 painful electrical shocks however the participants never received the shocks. To quantify the level of physiological arousal and the level of sympathetic outflow continuous beat-to-beat changes in heart rate (beats*min(-1)) and systolic, diastolic and mean arterial blood pressure (mmHg) were measured. To quantify position sense acuity absolute error (AE) expressed in degrees was measured. Two-way analysis of variance with repeated measurements (subjects as random factor and treatments as fixed factors) was used to compare the different treatments. RESULTS: Significant increases were observed in systolic blood pressure, diastolic blood pressure, and heart rate during the stress sessions indicating elevated sympathetic activity (15, 14 and 10%, respectively). Despite pronounced changes in the sympathetic activity and subjective experiences of stress no changes were found in position sense acuity in the rotational plane of the lumbar spine in the presence of the electrical shock stressor compared to the control period. CONCLUSION: The present findings indicate that position sense acuity in the rotational plane of the spine was unaffected by the electrical shock stressor

    Multiplicity dependence of the pion source in S + A collisions at the CERN SPS

    Get PDF
    The emission of pions from relativistic heavy-ion collisions of S + S, S + Ag and S + Pb at 200 GeV/nucleon is characterized using two-particle interferometry. The multiplicity dependence of the pion source parameters near mid-rapidity is studied. The transversal and longitudinal source parameters, RtR_t and RlR_l, show a clear increase with the particle multiplicity. The multiplicity dependence is weaker than that expected from a simple model of a freeze-out at a constant density. % The transversal and longitudinal source parameters RtR_t and RlR_l, show % a clear increase with the particle multiplicity, consistent with the model % of freeze-out at a constant density
    • …
    corecore