5,886 research outputs found

    DEVELOPMENT AND VALIDATION OF SPECTROPHOTOMETRIC AND ION PAIR CHROMATOGRAPHIC TECHNIQUE FOR ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE

    Get PDF
    Two new simple, sensitive, rapid, accurate and reproducible methods (UV-spectrophotometric and ion pair chromatography) have been developed for simultaneous estimation of valsartan (VAL) and hydrochlrothiazide (HCTZ) from their tablet dosage form. The first method involves multiwavelength spectrophotometric method (Method 1) in which interference of HCTZ at 245nm (wavelength for estimation of VAL) was removed by recording absorbance difference at 245nm and 301 nm whereas HCTZ was estimated directly from its absorbance at 316 nm at which VAL shows no absorbance. Linearity of the response was demonstrated by VAL in the concentration range of 5-45 g/ml with a square correlation coefficient (r2) of 0.9998. Linearity of the response was demonstrated by HCTZ in the concentration range of 2-18 g/ml with a square correlation coefficient (r2) of 0.9994. The second method utilizes ion pair chromatography (Method 2) on a HIQ sil ODS column (250 mm* 4.6 mm i.d.) using methanol: 0.0025 M orthophosphoric acid: (70:30 by volume) having pH 4.6: 0.1% hexane sulphonic acid as mobile phase with UV detection at 259nm over concentration range for VAL is 240-0 μg/ml, and for HCTZ is 75-0μg/ml. Losartan potassium was used as the internal standard. The suggested procedures were checked using laboratory prepared mixtures and were applied successfully for the analysis of their tablet dosage form. The results of analysis were statistically analysed. Both the methods were validated as per ICH Q2B guideline

    High-fidelity simulation of an ultrasonic standing-wave thermoacoustic engine with bulk viscosity effects

    Full text link
    We have carried out boundary-layer-resolved, unstructured fully-compressible Navier--Stokes simulations of an ultrasonic standing-wave thermoacoustic engine (TAE) model. The model is constructed as a quarter-wavelength engine, approximately 4 mm by 4 mm in size and operating at 25 kHz, and comprises a thermoacoustic stack and a coin-shaped cavity, a design inspired by Flitcroft and Symko (2013). Thermal and viscous boundary layers (order of 10 μ\mathrm{\mu}m) are resolved. Vibrational and rotational molecular relaxation are modeled with an effective bulk viscosity coefficient modifying the viscous stress tensor. The effective bulk viscosity coefficient is estimated from the difference between theoretical and semi-empirical attenuation curves. Contributions to the effective bulk viscosity coefficient can be identified as from vibrational and rotational molecular relaxation. The inclusion of the coefficient captures acoustic absorption from infrasonic (∼\sim10 Hz) to ultrasonic (∼\sim100 kHz) frequencies. The value of bulk viscosity depends on pressure, temperature, and frequency, as well as the relative humidity of the working fluid. Simulations of the TAE are carried out to the limit cycle, with growth rates and limit-cycle amplitudes varying non-monotonically with the magnitude of bulk viscosity, reaching a maximum for a relative humidity level of 5%. A corresponding linear model with minor losses was developed; the linear model overpredicts transient growth rate but gives an accurate estimate of limit cycle behavior. An improved understanding of thermoacoustic energy conversion in the ultrasonic regime based on a high-fidelity computational framework will help to further improve the power density advantages of small-scale thermoacoustic engines.Comment: 55th AIAA Aerospace Sciences Meeting, AIAA SciTech, 201

    Synthesis, Characterization and Quantification of Simvastatin Metabolites and Impurities

    Get PDF
    Simvastatin is used in treatment of hypercholesterolemia because it regulates cholesterol synthesis as a result of its β-hydroxy acid acting as an inhibitor of 3-hydroxy-methylglutaryl coenzyme A (HMG-CoA). The present communication deals with synthesis, characterization and development of accurate, precise and sensitive Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for simultaneous estimation of simvastatin and its synthetic impurities. The impurities methyl ether and β-hydroxy acid of simvastatin were synthesized in the laboratory and characterized by MS, NMR and FT-IR spectroscopy. The separation of simvastatin and its impurities was carried out on an isocratic JASCO RP-HPLC system using KYA TECH HIQ SIL C18 column (150 × 4.6 mm internal diameter, particle size 5 μm) operating at ambient temperature using acetonitrile:water (80:20 v/v) with 0.1% orthophosphoric acid as mobile phase. The method developed for HPLC analysis of three impurities along with simvastatin was validated using ICH Q2B (R1) guidelines and it complied with these guidelines. The results of analysis were found to be in the range of 98.14% to 101.89% for all analytes with acceptable accuracy and precision. The method can be used for detection and quantification of synthetic impurities in bulk or formulations of simvastatin

    Operator monotones, the reduction criterion and the relative entropy

    Get PDF
    We introduce the theory of operator monotone functions and employ it to derive a new inequality relating the quantum relative entropy and the quantum conditional entropy. We present applications of this new inequality and in particular we prove a new lower bound on the relative entropy of entanglement and other properties of entanglement measures.Comment: Final version accepted for publication, added references in reference [1] and [13

    Information theoretic treatment of tripartite systems and quantum channels

    Full text link
    A Holevo measure is used to discuss how much information about a given POVM on system aa is present in another system bb, and how this influences the presence or absence of information about a different POVM on aa in a third system cc. The main goal is to extend information theorems for mutually unbiased bases or general bases to arbitrary POVMs, and especially to generalize "all-or-nothing" theorems about information located in tripartite systems to the case of \emph{partial information}, in the form of quantitative inequalities. Some of the inequalities can be viewed as entropic uncertainty relations that apply in the presence of quantum side information, as in recent work by Berta et al. [Nature Physics 6, 659 (2010)]. All of the results also apply to quantum channels: e.g., if \EC accurately transmits certain POVMs, the complementary channel \FC will necessarily be noisy for certain other POVMs. While the inequalities are valid for mixed states of tripartite systems, restricting to pure states leads to the basis-invariance of the difference between the information about aa contained in bb and cc.Comment: 21 pages. An earlier version of this paper attempted to prove our main uncertainty relation, Theorem 5, using the achievability of the Holevo quantity in a coding task, an approach that ultimately failed because it did not account for locking of classical correlations, e.g. see [DiVincenzo et al. PRL. 92, 067902 (2004)]. In the latest version, we use a very different approach to prove Theorem

    Gravitational Lensing Bound On The Average Redshift Of Gamma Ray Bursts In Models With Evolving Lenses

    Full text link
    Identification of gravitationally lensed Gamma Ray Bursts (GRBs) in the BATSE 4B catalog can be used to constrain the average redshift of the GRBs. In this paper we investigate the effect of evolving lenses on the of GRBs in different cosmological models of universe. The cosmological parameters $\Omega$ and $\Lambda$ have an effect on the of GRBs. The other factor which can change the istheevolutionofgalaxies.Weconsiderthreeevolutionarymodelofgalaxies.Inparticular,wefindthattheupperlimiton is the evolution of galaxies. We consider three evolutionary model of galaxies. In particular, we find that the upper limit on of GRBs is higher in evolving model of galaxies as compared to non-evolving models of galaxies.Comment: 23 pages,one plain LaTeX file with three postscript figures This is modified version with recent BATSE efficiency parameter and with the latest F paramete

    The ground state of a class of noncritical 1D quantum spin systems can be approximated efficiently

    Full text link
    We study families H_n of 1D quantum spin systems, where n is the number of spins, which have a spectral gap \Delta E between the ground-state and first-excited state energy that scales, asymptotically, as a constant in n. We show that if the ground state |\Omega_m> of the hamiltonian H_m on m spins, where m is an O(1) constant, is locally the same as the ground state |\Omega_n>, for arbitrarily large n, then an arbitrarily good approximation to the ground state of H_n can be stored efficiently for all n. We formulate a conjecture that, if true, would imply our result applies to all noncritical 1D spin systems. We also include an appendix on quasi-adiabatic evolutions.Comment: 9 pages, 1 eps figure, minor change

    Tremor in motor neuron disease may be central rather than peripheral in origin

    Get PDF
    BACKGROUND AND PURPOSE: Motor neuron disease (MND) refers to a spectrum of degenerative diseases affecting motor neurons. Recent clinical and post-mortem observations have revealed considerable variability in the phenotype. Rhythmic involuntary oscillations of the hands during action, resembling tremor, can occur in MND, but their pathophysiology has not yet been investigated. METHODS: A total of 120 consecutive patients with MND were screened for tremor. Twelve patients with action tremor and no other movement disorders were found. Ten took part in the study. Tremor was recorded bilaterally using surface electromyography (EMG) and triaxial accelerometer, with and without a variable weight load. Power spectra of rectified EMG and accelerometric signal were calculated. To investigate a possible cerebellar involvement, eyeblink classic conditioning was performed in five patients. RESULTS: Action tremor was present in about 10% of our population. All patients showed distal postural tremor of low amplitude and constant frequency, bilateral with a small degree of asymmetry. Two also showed simple kinetic tremor. A peak at the EMG and accelerometric recordings ranging from 4 to 12 Hz was found in all patients. Loading did not change peak frequency in either the electromyographic or accelerometric power spectra. Compared with healthy volunteers, patients had a smaller number of conditioned responses during eyeblink classic conditioning. CONCLUSIONS: Our data suggest that patients with MND can present with action tremor of a central origin, possibly due to a cerebellar dysfunction. This evidence supports the novel idea of MND as a multisystem neurodegenerative disease and that action tremor can be part of this condition
    • …
    corecore