224 research outputs found

    The first large-area, high-X-ray energy phase contrast prototype for enhanced detection of threat objects in baggage screening

    Get PDF
    X-ray imaging is the most commonly used method in baggage screening. Conventional x-ray attenuation (usually in dual-energy mode) is exploited to discriminate threat and non-threat materials: this is essentially, a method that has seen little changes in decades. Our goal is to demonstrate that x-rays can be used in a different way to achieve improved detection of weapons and explosives. Our approach involves the use of x-ray phase contrast and it a) allows much higher sensitivity in the detection of object edges and b) can be made sensitive to the sample’s microstructure. We believe that these additional channels of information, alongside conventional attenuation which would still be available, have the potential to significantly increase both sensitivity and specificity in baggage scanning. We obtained preliminary data demonstrating the above enhanced detection, and we built a scanner (currently in commissioning) to scale the concept up and test it on real baggage. In particular, while previous X-ray phase contrast imaging systems were limited in terms of both field of view (FOV) and maximum x-ray energy, this scanner overcomes both those limitations and provides FOVs up to 20 to 50 cm2 with x-ray energies up to 100 keV

    Asymmetric masks for large field-of-view and high-energy X-ray phase contrast imaging

    Get PDF
    We report on a large field of view, laboratory-based X-ray phase-contrast imaging setup. The method is based upon the asymmetric mask design that enables the retrieval of the absorption, refraction and scattering properties of the sample without the need to move any component of the imaging system. This can be thought of as a periodic repetition of a group of three (or more) apertures arranged in such a way that each laminar beam, defined by the apertures, produces a different illumination level when analysed with a standard periodic set of apertures. The sample is scanned through the imaging system, also removing possible aliasing problems that might arise from partial sample illumination when using the edge illumination technique. This approach preserves the incoherence and achromatic properties of edge illumination, removes the problems related to aliasing and it naturally adapts to those situations in clinical, industrial and security imaging where the image is acquired by scanning the sample relative to the imaging system. These concepts were implemented for a large field-of-view set of masks (20 cm × 1.5 cm and 15 cm × 1.2 cm), designed to work with a tungsten anode X-ray source operated up to 80–100 kVp, from which preliminary experimental results are presented

    Large field-of-view asymmetric masks for high-energy x-ray phase imaging with standard x-ray tube

    Get PDF
    We report on a new approach to large field-of-view laboratory-based X-ray phase-contrast imaging. The method is based upon the asymmetric mask design that enables the retrieval of the absorption, refraction and ultra-small- angle scattering properties of the sample without the need to move any component of the imaging system. The sample is scanned through the imaging system, which also removes possible aliasing problems that might arise from partial sample illumination when using the edge illumination technique. This concept can be extended to any desired number of apertures providing, at the same time, intensity projections at complementary illumination conditions. Experimental data simultaneously acquired at seven different illumination fractions are presented along with the results obtained from a numerical model that incorporates the actual detector performance. The ultimate shape of the illumination function is shown to be significantly dependent on these detector-specific characteristics. Based on this concept, a large field-of-view system was designed, which is also capable to cope with relatively high (100 kVp) X-ray energies. The imaging system obtained in this way, where the asymmetric mask design enables the data to be collected without moving any element of the instrumentation, adapts particularly well to those situations in medical, industrial and security imaging where the sample has to be scanned through the syste

    Designing a Heat Sink for Lithium-ion Battery Packs in Electric Vehicles

    Get PDF
    This report addresses the concepts and implementation of fluid cooled heat sink designs for an electric or hybrid vehicle battery. To determine the battery’s temperature and heat flux profile, testing was performed by measuring these values at multiple locations on a lithium-ion pouch battery using heat flux sensors and thermocouples during the charge and discharge cycles of the battery. Once the data was collected and analyzed, trendlines were fit to the heat flux data then used to create equations for the heat flux profile during the discharging stage. Each equation represented a specific region on the battery geometry. Four heat sink designs were modeled in COMSOL Multiphysics to optimize cooling. The third model concept (Model 3) was chosen as the best model because it cooled the battery to the lowest temperature with the lowest pressure drop

    Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy

    Get PDF
    X-ray phase contrast imaging (XPCI) is an innovative imaging technique which extends the contrast capabilities of ‘conventional’ absorption based x-ray systems. However, so far all XPCI implementations have suffered from one or more of the following limitations: low x-ray energies, small field of view (FOV) and long acquisition times. Those limitations relegated XPCI to a ‘research-only’ technique with an uncertain future in terms of large scale, high impact applications. We recently succeeded in designing, realizing and testing an XPCI system, which achieves significant steps toward simultaneously overcoming these limitations. Our system combines, for the first time, large FOV, high energy and fast scanning. Importantly, it is capable of providing high image quality at low x-ray doses, compatible with or even below those currently used in medical imaging. This extends the use of XPCI to areas which were unpractical or even inaccessible to previous XPCI solutions. We expect this will enable a long overdue translation into application fields such as security screening, industrial inspections and large FOV medical radiography – all with the inherent advantages of the XPCI multimodality

    Phase Contrast Imaging Using a Single Picosecond X-ray Pulse of the Inverse Compton Source at the Bnl Accelerator Test Facility

    Get PDF
    Inverse Compton scattering (ICS) X-ray sources are of current interest due to their novel features that enable new methods in medical and biological imaging. As a compelling example of such a possibility, we present an experimental demonstration of single shot inline phase contrast imaging using the ICS source located at the BNL Accelerator Test Facility. The phase contrast effect is clearly observed in the images obtained. Further, its qualities are shown to be in agreement with the predictions of theoretical models through comparison of experimental and simulated images of a set of plastic wires of differing composition and size. We also display an example of application of the technique to single shot phase contrast imaging of a biological sample

    The Wisconsin Plasma Astrophysics Laboratory

    Full text link
    The Wisconsin Plasma Astrophysics Laboratory (WiPAL) is a flexible user facility designed to study a range of astrophysically relevant plasma processes as well as novel geometries that mimic astrophysical systems. A multi-cusp magnetic bucket constructed from strong samarium cobalt permanent magnets now confines a 10 m3^3, fully ionized, magnetic-field free plasma in a spherical geometry. Plasma parameters of Te≈5 T_{e}\approx5 to 2020 eV and ne≈1011n_{e}\approx10^{11} to 5×10125\times10^{12} cm−3^{-3} provide an ideal testbed for a range of astrophysical experiments including self-exciting dynamos, collisionless magnetic reconnection, jet stability, stellar winds, and more. This article describes the capabilities of WiPAL along with several experiments, in both operating and planning stages, that illustrate the range of possibilities for future users.Comment: 21 pages, 12 figures, 2 table
    • …