11 research outputs found

    Characterization of Thermally Oxidized Ti6Al4V Alloys for Dental Application

    Get PDF
    In this work, thermal oxidation processes in the temperature range of 500-800 °C in air for 4 hours were performed on Ti6Al4V medical grade alloys to modify their surface structure and morphology for better wear and corrosion resistance, osseointegration and biocompatibility. Different type and amount of nanostructured phases were obtained as revealed by the X-ray diffration (XRD) technique such as: alumina, anatase and rutile. X’pert high score plus software was used for the calculation of the percentage and crystallite sizes of these phases. Alumina phase exhibits the greater amount of the oxide layers when Ti6Al4V alloys annealed at 500 °C, while rutile was found to be the predominant phase at 800 °C

    Вплив товщини пластини та кількості сіток трафаретного друку на Al-BSF у кристалічних кремнієвих сонячних елементах

    No full text
    У роботі були проведені експериментальні дослідження процесу легування алюмінієвих (Al) паст, надрукованих трафаретним друком на кремнієвих поверхнях для сонячних елементів. Досліджений вплив товщини пластини та кількості сіток трафаретного друку на властивості поля задньої поверхні Al (Al-BSF) кремнієвих сонячних елементів Чохральського (Cz-Si). Використовувалися екрани з різною кількістю сіток (150, 200 і 400 меш) для друку різної кількості пасти Al (7, 9,4 та 12 мг/см2). Швидкий термічний відпал (RTP) при 750 °C і 800 °C протягом 60 с був застосований для формування ALBSF. SEM показав утворення шорсткої поверхні з шаром легуючого шару товщиною 4,31 мкм на об’ємній кремнієвій пластині. Аналіз ECV та SIMS показав, що пікова температура відпалу 750 °C і кількість пасти Al 12 мг/см2 підходять для створення оптимального Al-BSF. Ця робота виявила, що на властивості Al-BSF сильно впливає кількість меш, яка використовується для трафаретного друку пасти Al. Однак не було помічено монотонного зв’язку з товщиною пластини. Маска з 150 меш дозволила отримати високі концентрації Al на поверхні, максимальну глибину дифузії та більший середній час життя носіїв заряду.In this study, experiments on the alloying process from screen-printed aluminum (Al) pastes on silicon surfaces for solar cell applications were conducted. We investigated the effect of wafer thickness and screen-printing mesh counts on the Al back surface field (Al-BSF) properties of Czochralski silicon (Cz-Si) solar cells Screens with different mesh counts (150, 200 and 400 mesh) were used to print variable amounts of Al paste (7, 9.4 and 12 mg/cm2). Rapid thermal annealing (RTP) annealing processes of 750 °C and 800 °C for 60 s were applied to form AL-BSF. SEM micrographs showed the formation of a rough surface with 4.31 µm alloying layer over bulk Si wafer. ECV and SIMS analysis showed that an annealing peak temperature of 750 °C and an amount of Al paste of 12 mg/cm2 are suitable for the creation of an optimal Al-BSF. This work revealed that Al-BSF properties are strongly affected by the mesh counts used in screen-printing of Al paste. However, no monotonic relationship was noticed with the wafer thickness. The mask with 150 meshes allowed to obtain high Al concentrations at the surface, maximum diffusion depth and longer average lifetimes of charge carriers

    Comparison of ECG-based physiological markers for hypoxia in a preterm ovine model

    No full text
    BACKGROUND: Current methods for assessing perinatal hypoxic conditions did not improve infant outcomes. Various waveform-based and interval-based ECG markers have been suggested, but not directly compared. We compare performance of ECG markers in a standardized ovine model for fetal hypoxia. METHODS: Sixty-nine fetal sheep of 0.7 gestation had ECG recorded 4 h before, during, and 4 h after a 25-min period of umbilical cord occlusion (UCO), leading to severe hypoxia. Various ECG markers were calculated, among which were heart rate (HR), HR-corrected ventricular depolarization/repolarization interval (QTc), and ST-segment analysis (STAN) episodic and baseline rise markers, analogue to clinical STAN device alarms. Performance of interval- and waveform-based ECG markers was assessed by correlating predicted and actual hypoxic/normoxic state. RESULTS: Of the markers studied, HR and QTc demonstrated high sensitivity (≥86%), specificity (≥96%), and positive predictive value (PPV) (≥86%) and detected hypoxia in ≥90% of fetuses at 4 min after UCO. In contrast, STAN episodic and baseline rise markers displayed low sensitivity (≤20%) and could not detect severe fetal hypoxia in 65 and 28% of the animals, respectively. CONCLUSION: Interval-based HR and QTc markers could assess the presence of severe hypoxia. Waveform-based STAN episodic and baseline rise markers were ineffective as markers for hypoxia
    corecore