21 research outputs found
State of the art in bile analysis in forensic toxicology
AbstractIn forensic toxicology, alternative matrices to blood are useful in case of limited, unavailable or unusable blood sample, suspected postmortem redistribution or long drug intake-to-sampling interval. The present article provides an update on the state of knowledge for the use of bile in forensic toxicology, through a review of the Medline literature from 1970 to May 2015. Bile physiology and technical aspects of analysis (sampling, storage, sample preparation and analytical methods) are reported, to highlight specificities and consequences from an analytical and interpretative point of view. A table summarizes cause of death and quantification in bile and blood of 133 compounds from more than 200 case reports, providing a useful tool for forensic physicians and toxicologists involved in interpreting bile analysis. Qualitative and quantitative interpretation is discussed. As bile/blood concentration ratios are high for numerous molecules or metabolites, bile is a matrix of choice for screening when blood concentrations are low or non-detectable: e.g., cases of weak exposure or long intake-to-death interval. Quantitative applications have been little investigated, but small molecules with low bile/blood concentration ratios seem to be good candidates for quantitative bile-based interpretation. Further experimental data on the mechanism and properties of biliary extraction of xenobiotics of forensic interest are required to improve quantitative interpretation
Analysis of 8years activity of the mobile rehabilitation team in the Besançon University Hospital
International audienc
Postmortem measurement of human chorionic gonadotropin in vitreous humor and bile.
Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest
A case of suicide by self-injection of adrenaline.
Adrenaline (epinephrine) auto-injectors provide life-saving pre-hospital treatment for individuals experiencing anaphylaxis in a community setting. Errors in handling adrenaline auto-injectors, particularly by children and healthcare professionals, have been reported. Reports of adrenaline overdoses are limited in the medical literature. In most of these cases, accidental adrenaline administration results from medical error. Exogenous administration of catecholamine is responsible for cardiovascular and metabolic responses, which may cause supraventricular tachycardia, ventricular dysrhythmias and myocardial ischemia. The authors present a unique autopsy case involving a 34 year-old woman who intentionally self-injected adrenaline using an adrenaline auto-injector as part of a suicide plan. Catecholamines and metanephrines were measured in peripheral and cardiac blood as well as urine and vitreous humor. Based on the results of all postmortem investigations, the cause of death was determined to be cardiac dysrhythmia and cardiac arrest following adrenaline self-injection