1 research outputs found

    Risk factors in patient safety: minimally invasive surgery versus conventional surgery

    Get PDF
    Background This study aimed to identify the frequency of events in the different patient safety risk domains during minimally invasive surgery (MIS) and conventional surgery (CS). Methods A convenience sample of gynecologic MIS and CS was observed. Events were observed and categorized into one of the predefined patient safety risk domains. Results A total of 53 procedures were observed: 26 CS and 27 MIS procedures. The general characteristics were comparable between the two groups. A large number of environmental events were observed, averaging one every 2.5 min. Technical events and events of an organizational nature occurred more often in MIS (P < 0.01) than in CS (P < 0.01). The relative risk for the occurrence of one or more technical events in MIS compared with CS was 1.7, and the risk for two or more technical events was 4.1. A time out according to protocol showed no relationship to the occurrence of the different types of patient safety-related events. Conclusion The technological complexity inherent in MIS makes this type of surgery more prone to technology-related problems than CS, even in a specially designed minimally invasive surgical suite. A regular time-out procedure developed for CS lacks the attention necessary for the complex technology used in MIS and therefore is insufficient for MIS procedures briefing. Incorporating a specially designed technology checklist in a regular briefing protocol could be a solution to decrease the number of events in MIS.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin