23 research outputs found

    An in vitro evaluation of standard rotational thromboelastography in monitoring of effects of recombinant factor VIIa on coagulopathy induced by hydroxy ethyl starch

    Get PDF
    BACKGROUND: Rotational thromboelastography (ROTEG) has been proposed as a monitoring tool that can be used to monitor treatment of hemophilia with recombinant factor VIIa (rFVIIa). In these studies special non-standard reagents were used as activators of the coagulation. The aim of this study was to evaluate if standard ROTEG analysis could be used for monitoring of effects of recombinant factor VIIa (rFVIIa) on Hydroxy Ethyl Starch-induced dilutional coagulopathy. METHODS: The study was performed in vitro on healthy volunteers. Prothrombin time (PT) and ROTEG analysis were performed after dilution with 33% hydroxy ethyl starch and also after addition of rFVIIa to the diluted blood. RESULTS: PT was impaired with INR changing from 0.9 before dilution to 1.2 after dilution while addition of rFVIIa to diluted blood lead to an overcorrection of the PT to an International Normalized Ratio (INR) value of 0.6 (p = 0.01). ROTEG activated with the contact activator ellagic acid was impaired by hemodilution (p = 0.01) while addition of rFVIIa had no further effects. ROTEG activated with tissue factor (TF) was also impaired by hemodilution (p = 0.01) while addition of rFVIIa lead to further impairment of the coagulation (p = 0.01). CONCLUSIONS: The parameters affected in the ROTEG analysis were Clot Formation Time and Amplitude after 15 minutes while the Clotting Time was unaffected. We believe these effects to be due to methodological problems when using standard activators of the coagulation in the ROTEG analysis in combination with rFVIIa

    Criteria for the selective use of chest computed tomography in blunt trauma patients

    Get PDF
    Item does not contain fulltextPURPOSE: The purpose of this study was to derive parameters that predict which high-energy blunt trauma patients should undergo computed tomography (CT) for detection of chest injury. METHODS: This observational study prospectively included consecutive patients (>or=16 years old) who underwent multidetector CT of the chest after a high-energy mechanism of blunt trauma in one trauma centre. RESULTS: We included 1,047 patients (median age, 37; 70% male), of whom 508 had chest injuries identified by CT. Using logistic regression, we identified nine predictors of chest injury presence on CT (age >or=55 years, abnormal chest physical examination, altered sensorium, abnormal thoracic spine physical examination, abnormal chest conventional radiography (CR), abnormal thoracic spine CR, abnormal pelvic CR or abdominal ultrasound, base excess or=1 positive predictors, 484 had injury on CT (95% of all 508 patients with injury). Of all 192 patients with no positive predictor, 24 (13%) had chest injury, of whom 4 (2%) had injuries that were considered clinically relevant. CONCLUSION: Omission of CT in patients without any positive predictor could reduce imaging frequency by 18%, while most clinically relevant chest injuries remain adequately detected.1 april 201
    corecore