9 research outputs found

    Vaginal dose-surface maps in cervical cancer brachytherapy: Methodology and preliminary results on correlation with morbidity

    No full text
    PURPOSE: The purpose of the study was to develop a methodology for vaginal dose-surface maps (DSMs) in patients with cervix cancer and to investigate dose-surface histogram metrics as predictors for vaginal stenosis (St) and mucositis (Muc). METHODS AND MATERIALS: Thirty-one patients with locally advanced cervix cancer with no vaginal St/Muc (CTCAE-v3) G ≥ 2 at baseline were analyzed. Patients were divided in four morbidity groups: 15 with St/Muc G0/1, 6 with St G ≥ 2, 4 with St/Muc G ≥ 2, and 6 with Muc G ≥ 2. Patients received external beam radiotherapy and 4-fraction intracavitary/interstitial high-dose-rate brachytherapy using tandem and ovoids. DSMs were generated from inner/outer vaginal surfaces. DSMs of external beam radiotherapy and brachytherapy (Gy EQD2 3) were added based on a system of homologous points, to generate cumulative DSMs. Dose-surface histogram/dose-volume histogram parameters, location of high/intermediate-dose regions, rectovaginal reference point, vaginal lateral 5 mm point doses, and vagina/implant dimensions were investigated for St and Muc prediction. Average/difference DSMs and one-way analysis of variance were used to compare between groups. RESULTS: Best predictors of stenosis were D 15-25cm2 and upper-vagina S 65-120Gy(%). Cutoffs of ∼90 Gy EQD2 3 for D 20cm2 and ∼80% for S 65Gy to top 3 cm inner vaginal surface suitably discriminated for stenosis. Spatial dose location on average/difference DSMs showed significantly higher doses (by > 20 Gy, p < 0.001) over longer parts of the dorsolateral vagina and higher rectovaginal reference point doses for any G ≥ 2 morbidity, over the whole circumference of the upper vagina for G ≥ 2 stenosis. Dose-volume histogram parameters were dependent on vaginal wall thickness. An increase of wall thickness from 2 to 4 mm resulted in an increase of D 2cm3 (D 4cm3) of 16% (32%). CONCLUSIONS: A novel method was developed to generate vaginal DSMs and spatial-dose metrics. DSMs were found to correlate with vaginal stenosis. The findings of this study are promising and should be further validated on a larger patient cohort, treated with different applicators

    Cervical cancer apparent diffusion coefficient values during external beam radiotherapy

    Get PDF
    Background and purpose: Apparent diffusion coefficient (ADC) reflects micro-enviromental changes and therefore might be useful in predicting recurrence prior to brachytherapy. The purpose of this study is to evaluate change in ADC of the primary tumour and pathologic lymph nodes during treatment and to correlate this with clinical outcome. Material and methods: Twenty patients were included who received chemoradiation for locally advanced cervical cancer between July 2016 and November 2017. All patients underwent magnetic resonance imaging (MRI) prior to treatment, and three MRIs in weeks 1/2, 3 and 4 of treatment, including T2 and diffusion weighted imaging (b-values 0, 200, 800 s/mm2) for determining an ADC-map. Primary tumour was delineated on T2 and ADC-map and pathologic lymph nodes were delineated only on ADC-map. Results: At time of analysis median follow-up was 15 (range 7–22) months. From MRI one to four, primary tumour on ADC-map showed a significant signal increase of 0.94 (range 0.74–1.46) × 10−3 mm2/s to 1.13 (0.98–1.49) × 10−3 mm2/s (p < 0.001). When tumour was delineated on T2, ADC-value signal increase (in tumour according to T2) was similar. All 46 delineated pathologic lymph nodes showed an ADC-value increase on average from 0.79 (range 0.33–1.12) × 10−3 mm2/s to 1.14 (0.59–1.75) × 10−3 mm2/s (p < 0.001). The mean tumour/suspected lymph node volumes decreased respectively 51/40%. Four patients developed relapse (one local and three nodal), without clear relation with ΔADC. However, the median volume decrease of the primary tumour was substantially lower in the failing patients compared to the group without relapse (19 vs. 57%). Conclusions: ADC values can be acquired using T2-based tumour delineations unless there are substantial shifts between ADC-mapping and T2 acquisition. It remains plausible that ΔADC is a predictor for response to EBRT. However, the correlation in this study was not statistically significant. Keywords: Cervical cancer, ADC map, MR

    Implementation of state-of-the-art (chemo)radiation for advanced cervix cancer in the Netherlands: A quality improvement program

    No full text
    Purpose: To report on the “Dutch Quality Improvement Project” regarding external beam (EBRT) and brachytherapy (BT) contouring and treatment planning for locally advanced cervical cancer (LACC). Material and methods: Two rounds of three workshops were organized. Data from two patients with LACC were made available for homework exercises. Contouring and treatment planning was asked for according to the EMBRACE-II protocol. The submissions were analysed and the results were addressed during the workshops. Results: Almost all invited centres participated. EBRT contouring guidelines were followed within acceptable range, with major effort needed with regard to the ITV concept. BT contouring was of good quality, with especially small discrepancies for centres already participating in EMBRACE.EBRT treatment planning results improved between workshops with more centres being able to fulfil the planning aims. Guidance was especially necessary to improve the coverage probability planning for affected nodes.For BT planning prioritizing between target coverage and OAR sparing improved over time; the variation in dose to vaginal points remained considerable, as did variation in loading patterns and spatial dose distribution.The project was highly appreciated by all participants. Conclusion: Homework and workshop activities provide a suitable platform for discussion, exchange of experience and improvement of quality and conformity. Due to this project, radiotherapy for LACC can be administered with better and more comparable quality throughout the Netherlands. Keywords: Quality assurance, Quality improvement, Education & trainin

    Multi-center dosimetric predictions to improve plan quality for brachytherapy for cervical cancer treatment

    Get PDF
    Background and purpose: Image-guided adaptive brachytherapy (IGABT) is an important modality in the cervical cancer treatment, and plan quality is sensitive to time pressure in the workflow. Patient anatomy-based quality-assurance (QA) with overlap volume histograms (OVHs) has been demonstrated to detect suboptimal plans (outliers). This analysis quantifies the possible improvement of plans detected as outliers, and investigates its suitability as a clinical QA tool in a multi-center setting. Materials and methods: In previous work OVH-based models were investigated for the use of QA. In this work a total of 160 plans of 68 patients treated in accordance with the current state-of-the-art IGABT protocol from Erasmus MC (EMC) were analyzed, with a model based on 120 plans (60 patients) from UMC Utrecht (UMCU). Machine-learning models were trained to define QA thresholds, and to predict dose D2cm3 to bladder, rectum, sigmoid and small bowel with the help of OVHs of the EMC cohort. Plans out of set thresholds (outliers) were investigated and retrospectively replanned based on predicted D2cm3 values. Results: Analysis of replanned plans demonstrated a median improvement of 0.62 Gy for all Organs At Risk (OARs) combined and an improvement for 96 % of all replanned plans. Outlier status was resolved for 36 % of the replanned plans. The majority of the plans that could not be replanned were reported having implantation complications or insufficient coverage due to tumor geometry. Conclusion: OVH-based QA models can detect suboptimal plans, including both unproblematic BT applications and suboptimal planning circumstances in general. OVH-based QA models demonstrate potential for clinical use in terms of performance and user-friendliness, and could be used for knowledge transfer between institutes. Further research is necessary to differentiate between (sub)optimal planning circumstances

    Dose-effect relationship between vaginal dose points and vaginal stenosis in cervical cancer: An EMBRACE-I sub-study

    No full text
    Background and purpose: To evaluate dose–effect relationships between vaginal dose points and vaginal stenosis in patients treated for locally advanced cervical cancer with radio(chemo)therapy and image-guided adaptive brachytherapy. Material and methods: Patients from six centres participating in the EMBRACE-I study were included. Information on doses to different vaginal dose points, including the Posterior-Inferior Border of Symphysis (PIBS) points and recto-vaginal reference (RV-RP) point, were retrieved from the treatment planning system. In addition, the vaginal reference length (VRL) was evaluated. Vaginal stenosis was prospectively assessed according to the CTCAEv3.0 system at baseline and follow-up. Primary endpoint was grade 2 or higher (G ≥ 2) vaginal stenosis. Impact of dose to the vaginal dose points, and impact of VRL, age, vaginal involvement and applicator on vaginal stenosis G ≥ 2 was evaluated with a Cox proportional-hazard regression model. Results: 301 patients were included. Median follow-up was 49 months. During follow-up, the incidence of G0, G1, G2, and G3 vaginal stenosis was 25% (76), 52% (158), 20% (59) and 3% (8), respectively. Median total doses to PIBS+2 cm, PIBS, PIBS-2 cm and the RV-RP were 52.9 (IQR 49.3–64.7), 41.0 (IQR 15.4–49.0), 4.1 (IQR 2.9–7.0) and 64.6 (IQR 60.0–70.6) Gy EQD23, respectively. Higher doses to the PIBS, PIBS + 2 cm and RV-RP points were significantly associated with increased risk for vaginal stenosis G ≥ 2. Other risk factors for vaginal stenosis were: vaginal involvement at diagnosis, higher age, shorter VRL and use of a tandem-ovoid applicator. Conclusion: Higher doses to the PIBS+2 cm, PIBS and RV-RP dose points are associated with vaginal stenosis G ≥ 2
    corecore