22 research outputs found

    Comparison of three with six regions of interest analyses in patients with idiopathic constipation undertaking colon transit scintigraphy using 67Ga-citrate

    Get PDF
    OBJECTIVE AND INTRODUCTION: Preparation of data from 6 geometric regions of interest in the colon is time consuming, and can become impractical in the environment of busy Nuclear Medicine Departments. Therefore, we have investigated and demonstrated an alternative method for obtaining the same diagnostic information from an analysis of patients with idiopathic constipation who underwent colon transit scintigraphy using 67Ga-citrate. Data analysis methods using three regions of interest are compared to the results obtained using the more time consuming 6 regions of interest method to analyze the data. MATERIALS AND METHODS: In this study, we report our results of the comparative reanalysis of data obtained by more traditional methods. We compare 3 regions of interest (ROI) which were taken from areas including the right colon, left colon and the rectosigmoid colon, with original work using our alternative 6 (ROI) diagnostic methodology. In addition, the proximal colonic emptying (PCE) was determined at 24 hr post ingestion among members of 3 identified subject groups. RESULTS: The distribution of activity as the ingested 67Ga-citrate passes through the colon constitutes an activity profile. The mean activity position in the colon can be determined from subsequent radiographic images and from this the mean clearance time can be calculated. In quantitative assessment, this represents the time at which half of activity was eliminated from colon (mean half clearance time - MCT) which did not appear different in the reanalysis. There is no significant difference in the current study in GMC 24h, GMC 48h and GMC 72h between two groups using the Man Whitney u test (p > 0.05), while in the previous work the results were statistically significant for the two later time periods GMC (GMC 48h and GMC 72h) (p = 0.016 and p = 0.027 respectively). The PCE in the group 1 was = 2.50 (0.37); group 2, 1.57 (0.47) and group 3, 2.97. The PCE was not different between the two groups (p = 0.21). CONCLUSIONS: This investigation demonstrated that the radionuclide colon transit study using 67Ga-citrate is a safe, physiologic, and quantitative method for evaluating the transit of fecal material from cecum to rectum. Although, the visual assessment of diagnosis of the subjects in the two analyses is the same, it was not completely supported by quantitative measurements. Therefore, further studies need to be done

    Radiation exposure from diagnostic nuclear medicine examinations in golestan province

    Get PDF
    Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated using standard dosimetry tables. Results: Based on the data of this study, results of 10437 nuclear medicine procedures performed during 4 years have lead to 3.97 mSv as average effective dose per examination and 10.37 human-Sv as mean collective effective dose. It was also revealed that Tc-99m was the main source of effective dose (98.3%), bone scan was the most common procedure (25.9%) and cardiac scan (MIBI-rest) has the highest collective effective dose (33.5%) during 4 years. Conclusion: Beside the cardiac scan which was the most common nuclear medicine procedure and the main contributor of effective dose in patients, due to geographical condition of the northeast of Iran, bone scan was the highest performed nuclear medicine examination in the Golestan province

    Comparison of technetium-99m IgG with technetium-99m red blood cells labeling in cardiac blood-pool scintigraphy: A preliminary study

    Get PDF
    This first clinical prospective study was conducted to use of technetium-99m immunoglobulin G (99mTc-IgG) as compared with autologous 99mTc-red blood cells (RBC) in gated blood pool ventriculography. We studied 12 patients who referred to us for a possible diagnosis of liver hemangioma or infection. Six patients underwent gated planar blood pool (GPBP) acquisition using 99mTc-RBC and 6 GPBP acquisition using 99mTc-IgG. The use of 99mTc-IgG in cardiac blood pool studies provided comparable images to 99mTc-RBC. In conclusion, 99mTc-IgG, which is readily available and needs only a single injection, may be an attractive alternative to 99mTc-RBC for the estimation of various cardiac function parameters like left ventricular function

    The utility and prognostic value of dipyridamole technetium-99m sestamibi myocardial perfusion imaging SPECT in predicting perioperative cardiac events following non-cardiac surgery

    No full text
    Objective: A perioperative cardiac events is one of the most important medical concerns for both surgeons and patients. The purpose of the current study was to determine the prognostic value of myocardial perfusion imaging (MPI), using dipyridamole 99m Tc-MIBI, for the prediction of perioperative cardiac events. Materials and methods: This study included 253 patients who were candidates for non-cardiac elective surgery and underwent scanning with dipyridamole 99m Tc-MIBI. Based on normal or abnormal MPI, patients were divided into two groups and all preoperative cardiac events were recorded. Risk factors, including diabetes mellitus, dyslipidemia, hypertension, smoking and age .70 years, were compared between patients with normal and abnormal MPI and, also, in patients with or without cardiac events. Results: There were 197 patients with normal and 56 patients with abnormal MPI. In total, 14 patients had perioperative cardiac events, which included myocardial infarction (MI), hypotension, arrhythmia and death; of the 14 patients with perioperative cardiac events, 12 had abnormal and two had normal MPI. There were statistically meaningful differences between the two groups (p<0.001). Based on these findings, we determined that MPI had a sensitivity of 85.7%, a specificity of 81.6%, an accuracy of 81.8%, a positive predictive value of 21.4 % and a negative predictive value of 98.9%. Conclusion: The incidence of perioperative cardiac events is higher in patients with abnormal MPI. Dipyridamole 99m Tc-MIBI myocardial perfusion imaging can accurately detect the preoperative cardiac risk of patients undergoing major non-cardiac surgery. Based on these findings, the occurrence of perioperative cardiac events in patients with abnormal MPI should be considered, especially in the older age population (age ≥70). © The Author(s) 2013

    A study of the time of hospital discharge of differentiated thyroid cancer patients after receiving iodine-131 for thyroid remnant ablation treatment

    Get PDF
    The aim of this study was to measure the radiation exposure rate from differentiated thyroid carcinoma (DTC) patients who had received iodine-131 (131I) treatment, and to evaluate hospital discharge planning in relation to three different sets of regulations. We studied 100 patients, 78 females and 22 males, aged 13 to 79 years (mean 44.40±15.83 years) with DTC, in three Groups who were treated with 3.7, 5.5 or 7.4GBq of 131I, respectively. The external whole-body dose rates following oral administration of 131I were measured after each one of the first three hospitalization days. A multivariant linear analysis was performed, considering exposure rates as dependent variables to the administered dose for treatment, age, gender, regional and/or distant metastases, thyroglobulin (Tg), antibodies to Tg and thyroid remnant in the three dose groups. We found that the exposure rates after each of the three first days of hospitalization were 30, 50 and 70μSvh-1 at 1m. All our DTC patients had an acceptable dose rate on days 2 and 3 that allowed their hospital discharge. After only 1 day of hospitalization, just 3/11 cases showed not permissible exposure rates above 70μSvh-1. In conclusion, it is the opinion of the authors that after measuring the exposure rates, most treated, DTC patients could be discharged after only one day of hospitalization, even some of those treated with high doses of 131I (7.4GBq). Patients, who received the higher doses of 131I, should not be released before their individual exposure rate is measured

    Complete improvement in a patient with multiple irreversible defects of the left ventricle on 99m technetium-sestamibi SPECT after percutaneous coronary intervention.

    Get PDF
    99mTc-sestamibi has been investigated as a potential viability marker; initial studies have shown good concordance between 201Tl and 99mTc-sestamibi activities in both viable and nonviable myocardium. However, assessment of myocardial viability by 99mTc-sestamibi remains controversial for tissue recovery after revascularization. Here, we present a patient with several regions of severely diminished and irreversible (defect persisting in both early and delay images of each set scanning) defects on initial scan which were dissolved completely on the follow up scan after an intervention. In a 75 year-old Asian woman with acute myocardial infarction who received thrombolytic therapy and subjected to percutaneous coronary angiography (PCI) on day 28 after acute myocardial infarction(MI), resting 99mTc-sestamibi SPECT was applied on day 4 (initial scan) and 138 (follow up scan) after acute MI at 30 and 180 min after injection of tracer (740 MBq); Two-dimensional echocardiography was carried out at the same time. On the initial image set, there was irreversible defects in the apex, anteroapical, inferoapical, anteroseptal, septal and also anterior walls, while the follow up image was normal in all regions.The angiography intervention showed just significant stenosis on left anterior descending (LAD) vessel (95). This may highlight the failure of 99mTc-sestamibi as a marker of myocardial viability and also mandate further validating of the procedure with follow up scan or other modalities for myocardial viability investigation

    The diagnostic value of 99mTc-IgG scintigraphy in the diabetic foot and comparison with 99mTc-MDP scintigraphy

    No full text
    Diabetic foot infection is the most common etiology of nontraumatic amputation of the lower extremities, and early diagnosis is of great importance in its management. The aim of this prospective study was to evaluate the strength of 99mTc-IgG scintigraphy in diagnosis of osteomyelitis of the diabetic foot and to compare 99mTc-IgG scintigraphy with 99mTc-methylene diphosphonate (MDP) scintigraphy. Methods: A prospective university hospital-based study was performed over 24 mo. Eighteen patients with type II diabetes and foot ulcers (15 men and 3 women; age range, 45-80 y) were referred for imaging because of clinically suspected osteomyelitis. Early (5-h) and late (24-h) 99mTc-IgG scanning and 3-phase skeletal scintigraphy were completed for all patients at a 3- to 4-d interval. Regions of interest over the involved bony sites and the contralateral normal sites were drawn, and the abnormal-to-normal ratios were acquired for both 99mTc-IgG and 99mTc-MDP studies. Results: From a total of 23 lesions, we observed 10 sites of osteomyelitis, 10 sites of cellulitis, and 3 sites of aseptic inflammation confirmed by MRI, clinical presentation, histopathologic examination, and follow-up evaluation as a gold standard. Both 99mTc-IgG and 99mTc-MDP scanning showed excellent sensitivity for diagnosis of osteomyelitis, but the specificity was significantly lower (69.2% and 53.8%, respectively). Sensitivity, specificity, and accuracy in the diagnosis of osteomyelitis were, respectively, 100%, 53.8%, 73.9% for 99mTc-MDP scanning; 100%, 69.2%, 82.6% for 5-h 99mTc-IgG scanning; and 60%, 76.9%, 69.5% for 24-h 99mTc-IgG scanning. There was no significant difference between the semiquantitative indices of 5-h and 24-h 99mTc-IgG scanning for inflammation, cellulitis, and osteomyelitis. Conclusion: Although both 99mTc-IgG and 99mTc-MDP scintigraphy have high sensitivity for the diagnosis of osteomyelitis, the specificity of these studies is poor. For 99mTc-IgG scintigraphy, 5-h images appear to be adequate, and there is little benefit to performing additional imaging at 24 h. © 2011 by the Society of Nuclear Medicine, Inc

    Scintigraphic parameters with emphasis on perfusion appraisal in rest 99mTc-sestamibi SPECT in the recovery of myocardial function after thrombolytic therapy in patients with ST elevation myocardial infarction (STEMI)

    No full text
    Introduction: This study was performed to determine the clinical application of rest 99mTc-sestamibi in the assessment of viability and functional improvement of the left ventricle (LV) myocardium in the post-thrombolytic therapy of acute myocardial infarction (AMI). Material and methods: In 37 patients with AMI who received thrombolytic therapy, 2-dimensional (2D) echocardiography, as well as the resting redistribution of 99mTc-sestamibi, was investigated, both within 1 week and 3-5 months after AMI. The predictive capacity of the perfusion percentage for myocardial function recovery was evaluated. Also, the capacities of the possible variables in the prediction of recovery of myocardial function resulting from a change in LV ejection fraction (EF) were evaluated using stepwise multiple regression analysis. Results: Thirty-seven patients (30 men and 7 women; mean age: 58±14 years) with AMI were enrolled in the study. Redistribution was observed in 35 and 50 segments of the initial and follow-up scans, respectively. In addition, 146 segments with reverse redistribution (RR), both in the initial scan (118 segments) and the follow-up scan (86 segments), were also observed. An apparent difference in wall motion scores was seen between the initial and follow-up echocardiographs (p<0.001). Furthermore, using the optimal cut-off point of perfusion percentage in each image set, sensitivity as well as specificity and likelihood ratio (LR) for the improvement of regional wall motion after 3-5 months were defined. Conclusion: These data showed that redistribution and reverse redistribution of 99mTc-sestamibi post thrombolytic therapy can be used as a marker of viability to predict the recovery of segmental wall motion abnormality (stunning), as well as the improvement of segmental perfusion uptake. This study also demonstrates that the resting 99mTc-sestamibi SPECT can be used for an approximate assessment of LV function status and can predict the recovery of jeopardized myocardium function after thrombolytic therapy. © 2011 SAGE Publications

    Assessment of radioiodine clearance in patients with differentiated thyroid cancer

    No full text
    Radioiodine (131I iodide) has long been a safe, effective and widely used treatment in the management of differentiated thyroid cancer (DTC). Concerns regarding stochastic radiogenic risks have led to regulatory criteria for the release from medical confinement of patients who receive such radionuclide therapy. Over a 6-y period, the external whole-body dose rates at 1 m from 562 DTC patients were measured with an ionisation chamber calibrated in microsieverts per hour out to 5-d post-administration. Patients were stratified into four administered activity groups: 3.7 GBq (36.8 ), 5.55 GBq (47.3 ), 7.4 GBq (12.8 ) and 9.25 GBq (3 ). Consistent with previously published data, the current study demonstrated that a bi-phasic model accurately described 131I-iodide kinetics up to at least 5-d post-administration in DTC patients, providing data that would be useful in formulating radiation safety guidelines for staff and other individuals coming into contact with such patients after treatment. © The Author 2012. Published by Oxford University Press. All rights reserved
    corecore