289 research outputs found

    Training opportunities in thoracic ultrasound for respiratory trainees: are current guidelines practical?

    Get PDF
    Respiratory trainees in the UK face challenges in meeting current Royal College of Radiologists (RCR) Level 1 training requirements for thoracic ultrasound (TUS) competence, specified as attending 'at least one session per week over a period of no less than 3 months, with approximately five scans per session performed by the trainee (under supervision of an experienced practitioner)'. We aimed to clarify where TUS training opportunities currently exist for respiratory registrars.This is an Open Access article. Click on the Publisher URL to access the full-text

    Role of thoracic ultrasonography in pleurodesis pathways for malignant pleural effusions (SIMPLE): an open-label, randomised controlled trial

    Get PDF
    BACKGROUND: Pleurodesis is done as an in-patient procedure to control symptomatic recurrent malignant pleural effusion (MPE) and has a success rate of 75-80%. Thoracic ultrasonography has been shown in a small study to predict pleurodesis success early by demonstrating cessation of lung sliding (a normal sign seen in healthy patients, lung sliding indicates normal movement of the lung inside the thorax). We aimed to investigate whether the use of thoracic ultrasonography in pleurodesis pathways could shorten hospital stay in patients with MPE undergoing pleurodesis. METHODS: The Efficacy of Sonographic and Biological Pleurodesis Indicators of Malignant Pleural Effusion (SIMPLE) trial was an open-label, randomised controlled trial done in ten respiratory centres in the UK and one respiratory centre in the Netherlands. Adult patients (aged ≥18 years) with confirmed MPE who required talc pleurodesis via either a chest tube or as poudrage during medical thorascopy were eligible. Patients were randomly assigned (1:1) to thoracic ultrasonography-guided care or standard care via an online platform using a minimisation algorithm. In the intervention group, daily thoracic ultrasonography examination for lung sliding in nine regions was done to derive an adherence score: present (1 point), questionable (2 points), or absent (3 points), with a lowest possible score of 9 (preserved sliding) and a highest possible score of 27 (complete absence of sliding); the chest tube was removed if the score was more than 20. In the standard care group, tube removal was based on daily output volume (per British Thoracic Society Guidelines). The primary outcome was length of hospital stay, and secondary outcomes were pleurodesis failure at 3 months, time to tube removal, all-cause mortality, symptoms and quality-of-life scores, and cost-effectiveness of thoracic ultrasonography-guided care. All outcomes were assessed in the modified intention-to-treat population (patients with missing data excluded), and a non-inferiority analysis of pleurodesis failure was done in the per-protocol population. This trial was registered with ISRCTN, ISRCTN16441661. FINDINGS: Between Dec 31, 2015, and Dec 17, 2019, 778 patients were assessed for eligibility and 313 participants (165 [53%] male) were recruited and randomly assigned to thoracic ultrasonography-guided care (n=159) or standard care (n=154). In the modified intention-to-treat population, the median length of hospital stay was significantly shorter in the intervention group (2 days [IQR 2-4]) than in the standard care group (3 days [2-5]; difference 1 day [95% CI 1-1]; p<0·0001). In the per-protocol analysis, thoracic ultrasonography-guided care was non-inferior to standard care in terms of pleurodesis failure at 3 months, which occurred in 27 (29·7%) of 91 patients in the intervention group versus 34 (31·2%) of 109 patients in the standard care group (risk difference -1·5% [95% CI -10·2% to 7·2%]; non-inferiority margin 15%). Mean time to chest tube removal in the intervention group was 2·4 days (SD 2·5) versus 3·1 days (2·0) in the standard care group (mean difference -0·72 days [95% CI -1·22 to -0·21]; p=0·0057). There were no significant between-group differences in all-cause mortality, symptom scores, or quality-of-life scores, except on the EQ-5D visual analogue scale, which was significantly lower in the standard care group at 3 months. Although costs were similar between the groups, thoracic ultrasonography-guided care was cost-effective compared with standard care. INTERPRETATION: Thoracic ultrasonography-guided care for pleurodesis in patients with MPE results in shorter hospital stay (compared with the British Thoracic Society recommendation for pleurodesis) without reducing the success rate of the procedure at 3 months. The data support consideration of standard use of thoracic ultrasonography in patients undergoing MPE-related pleurodesis. FUNDING: Marie Curie Cancer Care Committee

    Exploiting light-based 3D-printing for the fabrication of mechanically enhanced, patient-specific aortic grafts

    Get PDF
    Despite polyester vascular grafts being routinely used in life-saving aortic aneurysm surgeries, they are less compliant than the healthy, native human aorta. This mismatch in mechanical behaviour has been associated with disruption of haemodynamics contributing to several long-term cardiovascular complications. Moreover, current fabrication approaches mean that opportunities to personalise grafts to the individual anatomical features are limited. Various modifications to graft design have been investigated to overcome such limitations; yet optimal graft functionality remains to be achieved. This study reports on the development and characterisation of an alternative vascular graft material. An alginate:PEGDA (AL:PE) interpenetrating polymer network (IPN) hydrogel has been produced with uniaxial tensile tests revealing similar strength and stiffness (0.39 ±0.05 MPa and 1.61 ±0.19 MPa, respectively) to the human aorta. Moreover, AL:PE tubular conduits of similar geometrical dimensions to segments of the aorta were produced, either via conventional moulding methods or stereolithography (SLA) 3D-printing. While both fabrication methods successfully demonstrated AL:PE hydrogel production, SLA 3D-printing was more easily adaptable to the fabrication of complex structures without the need of specific moulds or further post-processing. Additionally, most 3D-printed AL:PE hydrogel tubular conduits sustained, without failure, compression up to 50% their outer diameter and returned to their original shape upon load removal, thereby exhibiting promising behaviour that could withstand pulsatile pressure in vivo. Overall, these results suggest that this AL:PE IPN hydrogel formulation in combination with 3D-printing, has great potential for accelerating progress towards personalised and mechanically-matched aortic grafts

    Neck Surgery for Non-Well Differentiated Thyroid Malignancies: Variations in Strategy According to Histopathology

    Get PDF
    Lymph node metastases in non-well differentiated thyroid cancer (non-WDTC) are common, both in the central compartment (levels VI and VII) and in the lateral neck (Levels II to V). Nodal metastases negatively affect prognosis and should be treated to maximize locoregional control while minimizing morbidity. In non-WDTC, the rate of nodal involvement is variable and depends on the histology of the tumor. For medullary thyroid carcinomas, poorly differentiated thyroid carcinomas, and anaplastic thyroid carcinomas, the high frequency of lymph node metastases makes central compartment dissection generally necessary. In mucoepidermoid carcinomas, malignant peripheral nerve sheath tumors, sarcomas, and malignant thyroid teratomas or thyroblastomas, central compartment dissection is less often necessary, as clinical lymphnode involvement is less common. We aim to summarize the medical literature and the opinions of several experts from different parts of the world on the current philosophy for managing the neck in less common types of thyroid cancer
    corecore