3,083 research outputs found

    On the absolute value of the air-fluorescence yield

    Get PDF
    The absolute value of the air-fluorescence yield is a key parameter for the energy reconstruction of extensive air showers registered by fluorescence telescopes. In previous publications, we reported a detailed Monte Carlo simulation of the air-fluorescence generation that allowed the theoretical evaluation of this parameter. This simulation has been upgraded in the present work. As a result, we determined an updated absolute value of the fluorescence yield of 7.9+-2.0 ph/MeV for the band at 337 nm in dry air at 800 hPa and 293 K, in agreement with experimental values. We have also performed a critical analysis of available absolute measurements of the fluorescence yield with the assistance of our simulation. Corrections have been applied to some measurements to account for a bias in the evaluation of the energy deposition. Possible effects of other experimental aspects have also been discussed. From this analysis, we determined an average fluorescence yield of 7.04+-0.24 ph/MeV at the above conditions.Comment: Submitted to Astroparticle Physic

    Comparison of available measurements of the absolute air-fluorescence yield and determination of its global average value

    Get PDF
    Experimental results of the absolute air-fluorescence yield are given very often in different units (photons/MeV or photons/m) and for different wavelength intervals. In this work we present a comparison of available results normalized to its value in photons/MeV for the 337 nm band at 1013 hPa and 293 K. The conversion of photons/m to photons/MeV requires an accurate determination of the energy deposited by the electrons in the field of view of the experimental set-up. We have calculated the energy deposition for each experiment by means of a detailed Monte Carlo simulation and the results have been compared with those assumed or calculated by the authors. As a result, corrections to the reported fluorescence yields are proposed. These corrections improve the compatibility between measurements in such a way that a reliable average value with uncertainty at the level of 5% is obtained.Comment: 13 pages, 6 figures. To appear in the Proocedings of the International Symposium on the Recent Progress of Ultra-high Energy Cosmic Ray Observations (UHECR2010), Nagoya, Japan, 201

    Los cuerpos calzan en el revés de sus partes

    Get PDF
    In the rigor of the museum practices, among them restoration, dilemmas, contradictions and the aporia that implies a constant revision of its logics, this article consists of thinking from the visual and the problems of aesthetics, possible ideological articulations that materially resolve other ways of conceiving the museum object and its intervention within the field of restoration, using anatomical recombination as a formal and conceptual exercise. The marginal fragments call the text as a reflection on the processes of recombination as visual work.En el rigor de las prácticas museográficas, entre ellas la restauración, subyacen dilemas, contradicciones y aporías que implican una constante revisión de sus lógicas, este trabajo consiste en pensar desde la visualidad y los problemas de la estética, posibles articulaciones ideológicas que resuelvan materialmente otras maneras de concebir al objeto museográfico y su intervención dentro del campo de la restauración, utilizando la recombinación anatómica como ejercicio formal y conceptual. Los fragmentos marginales interpelan el texto en cuanto que reflexionan acerca de los procesos de recombinación como obra visual

    Comparison of available measurements of the absolute fluorescence yield

    Full text link
    The uncertainty in the absolute value of the fluorescence yield is still one of the main contributions to the total error in the reconstruction of the primary energy of ultra-energetic air showers using the fluorescence technique. A significant number of experimental values of the fluorescence yield have been published in the last years, however reported results are given very often in different units (photons/MeV or photons/m) and for different wavelength intervals. In this work we present a comparison of available results normalized to its value in photons/MeV for the 337 nm band at 800 hPa and 293 K. The conversion of photons/m to photons/MeV requires an accurate determination of the energy deposited by the electrons in the field of view of the experimental setup. We have calculated the energy deposition for each experiment by means of a detailed Monte Carlo simulation including when possible the geometrical details of the particular setup. Our predictions on deposited energy, as well as on some geometrical factors, have been compared with those reported by the authors of the corresponding experiments and possible corrections to the fluorescence yields are proposed.Comment: 29 pages, 5 figures Revised version submitted to Astroparticle Physic

    Hinting at primary composition using asymmetries in time distributions

    Get PDF
    Evidence of azimuthal asymmetries in the time structure and signal size have been found in non-vertical showers at the Pierre Auger Observatory. It has been previously shown that the asymmetry in time distributions offers a new possibility for the determination of the mass composition. New studies have demonstrated that the dependence of the asymmetry parameter in the rise-time and fall-time distributions with sec(theta) shows a clear peak. Both, the position of the peak, X_asymax, and the size of the asymmetry at X_asymax are sensitive to primary mass composition and have a small dependence on energy. In this paper a study of the discriminating power of the new observables to separate primary species is presented.Comment: To be published in the Proceedings of 29th International Cosmic Ray Conference (ICRC 2005), Pune, India, August 3-10, 200
    corecore