6 research outputs found

    Long term results of accelerated 9 mW corneal crosslinking for early progressive keratoconus: the Siena Eye-Cross Study 2

    Get PDF
    Purpose To assess clinical results of the 9 mW/5.4 J/cm(2) accelerated crosslinking (ACXL) in the treatment of progressive keratoconus (KC) over a span of 5 years. Methods The prospective open non-randomized interventional study (Siena Eye-Cross Study 2) included 156 eyes of 112 patients with early progressive KC undergoing the Epi-Off 9 mW/5.4 J/cm(2) ACXL at the Siena Crosslinking Centre, Italy. The mean age was 18.05 +/- 5.6 years. The 20-min treatments were performed using the New KXL I (Avedro, Waltham, USA), 10 min of 0.1% HPMC Riboflavin soaking (VibeX Rapid, Avedro, Waltham, USA) and 10 min of continuous-light UV-A irradiation. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), Kmax, coma, minimum corneal thickness (MCT), surface asymmetry index (SAI), endothelial cell count (ECC) were measured, and corneal OCT performed. Results UDVA and CDVA improved significantly at the 3rd (P = 0.028), Delta + 0.17 Snellen lines and 6th postoperative month, respectively (P < 0.001), Delta + 0.23 Snellen lines. Kmax improved at the 6th postoperative month (P = 0.03), Delta - 1.49 diopters from the baseline value. Also, coma aberration value improved significantly (P = 0.004). A mild temporary haze was recorded in 14.77% of patients without affecting visual acuity and without persistent complications. Corneal OCT revealed a mean demarcation line depth at 332.6 +/- 33.6 mu m. Conclusion The 5-year results of Epi-Off 9 mW/5.4 J/cm(2) ACXL demonstrated statistically significant improvements in UCVA and CDVA, corneal curvature and corneal higher-order aberrations which confers a long-term stability for progressive ectasia. Based on the results of the Siena Eye-Cross Study 2, the 9 mW/5.4 J/cm(2) ACXL is a candidate to be the natural evolution of Epi-Off CXL treatment for the management of early progressive corneal ectasia, and thus optimize clinic workflow

    Facilitating Role of the 3D Viewing System in Tilted Microscope Positions for Cataract Surgery in Patients Unable to Lie Flat

    No full text
    Purpose: To assess the utility of the 3D viewing system in tilted microscope positions for the performance of cataract surgery in challenging positions, for patients with difficulty remaining supine. Methods: Prospective, single-center, single-surgeon, consecutive case series of patients undergoing surgery in an inclined position. Results: 21 eyes of 15 patients who had undergone surgery at inclined positions at angles of 20° to 80°, with a mean angle of 47.62°. Surgeon comfort was considered to be globally good. The surgeon rated red reflex perception and the impression of depth as good and stable in all cases. The operating time was slightly longer for patients inclined at angles of more than 50°. On the first day after surgery, BSCVA was 20/25 or better in all cases. No ocular complications occurred in any of the interventions. Conclusions: Due to the ocular-free design of the 3D system, the surgical procedure and the positioning of the surgeon remained almost identical to that for patients undergoing surgery in a supine position, maintaining the safety of the standard surgical approach

    Ray-Tracing Transepithelial Excimer Laser Central Corneal Remodeling Plus Pachymetry-Guided Accelerated Corneal Crosslinking for Keratoconus.

    No full text
    PurposeThe aim of this study was to report the 12 to 96 months results of a tissue-preservation algorithm based on ray-tracing-guided transepithelial excimer laser central corneal ablation (RT t-PRK) combined with individualized pachymetry-guided accelerated crosslinking (M nomogram ACXL) in young adult patients with stable keratoconus (KC).MethodsThis was a prospective interventional study including 38 eyes of 38 young adult patients (stage II KC) with a mean age of 35 years (range 26-46 years) who underwent simultaneous RT with t-PRK plus pachymetry-based ACXL in the worst eye. The treatments were performed using the iViS Suite iRES Excimer Laser (Ligi, Taranto, Italy). Ray-tracing-guided treatments were planned using the customized interactive programmed transepithelial ablation (CIPTA) 2 web software and diagnostic data were assessed by the Precisio 2 tomographer (Ligi, Taranto, Italy) and Sirius tomographer (C.S.O., Florence, Italy). The main outcome measures included uncorrected distance visual acuity, best spectacle-corrected visual acuity, Kmax, high-order aberrations, minimum corneal thickness, and posterior elevation, with a mean follow-up of 52 months (range 12-96 m).ResultsThe mean UDVA improved + 3.5 ±1.28 Snellen lines (SL); 38% gained ≥ 4 ±1.34 SLs, 35% ≥ 3 ±1.21 SLs, 22% ≥ 2 ±1.12 SLs, and 5% ≥ 1 ±0.75 SLs. The mean best spectacle-corrected visual acuity increased by + 4.3 ±1.3 SL. Sixty-eight percent gained ≥ 4 ±0.88 SLs and 30% ≥ 3 ±0.78 SL. No SLs were lost.ConclusionsRT t-PRK plus ACXL significantly improved the quality of vision in patients with KC, preventing overcorrection and minimizing tissue consumption

    Use of Black-and-White Digital Filters to Optimize Visualization in Cataract Surgery

    No full text
    Purpose: To evaluate the effect of a black-and-white (BW) filter on the optimization of visualization at each stage of cataract surgery. Methods: Prospective, single-center, single-surgeon, consecutive case series of 40 patients undergoing cataract surgery with BW filter. Surgical images and videos were recorded with and without the BW filter at each stage of cataract surgery. Contrast measurements of surgical images and subjective analysis of video sequences were performed. Results: The surgeons assessed the BW filter to optimize the tissue visibility of capsulorhexis contours, hydrodissection fluid wave perception, the contrast of instruments through a nucleus during phaco-chop, and subincisional cortex contrast through the corneal edema. Despite the higher contrasts’ value obtained with BW filter images during nucleus removal, posterior capsular polishing and viscous removal, the surgeons subjectively reported no significant advantage of using a BW filter. Standard color images were found to be better for localizing the limbal area during incision and for nucleus sculpture to assess groove depth. Conclusions: In conclusion, we describe here the potential indications for BW filter use at particular stages in cataract surgery. A BW filter could be used, with caution, in cases of poor visualization

    Transepithelial Enhanced Fluence Pulsed Light M Accelerated Crosslinking for Early Progressive Keratoconus with Chemically Enhanced Riboflavin Solutions and Air Room Oxygen

    No full text
    Purpose: To assess the 3-year clinical results of the 18 mW 7 J/cm2 transepithelial enhanced fluence pulsed light M accelerated crosslinking in the treatment of progressive keratoconus (KC) with chemically enhanced hyper-concentrated riboflavin solutions without iontophoresis and with air-room oxygenation. Setting: Siena Crosslinking Center, Siena, Italy. Methods: Prospective pilot, open non-randomized interventional study including 40 eyes of 30 young adult patients over 21 years old (10 simultaneous bilateral) with early (Stage I and II) progressive KC undergoing TE-EFPL 18 mW/7 J/cm2 ACXL (EFPL M TECXL). The 12 min and 58 s pulsed light (1 s on/1 s off) UV-A exposure treatments were performed with a biphasic corneal soaking using Paracel I 0.25% for 4 min and Paracel II 0.22% for 6 min riboflavin solutions and New KXL I UV-A emitter (Glaukos-Avedro, Waltham, USA) at an air room of 21% oxygenation. All patients completed the 3-year follow-up. Results: CDVA showed a statistically significant improvement in the third postoperative month (Δ + 0.17 d. e.) with a final gain of +0.22 d. eq. AK showed a statistically significant decrease in the sixth postoperative month (Δ − 1.15 diopters). K itmax showed a statistically significant decrease at 1-year follow-up (Δ − 1.3 diopters). The coma value improved significantly by the sixth month (Δ − 0.54 µm). MCT remained stable during the entire follow-up. No adverse events were recorded. Corneal OCT revealed a mean demarcation line depth at 282.6 ± 23.6 μm. Conclusions: Transepithelial enhanced fluence pulsed light M accelerated crosslinking with chemically enhanced riboflavin solution halted KC progression in young adult patients without iontophoresis and no intraoperative oxygen supplementation addressing the importance of increased fluence

    Evaluation of Anterior and Posterior Corneal Higher Order Aberrations for the Detection of Keratoconus and Suspect Keratoconus

    Get PDF
    Aim: To investigate the application of anterior and posterior corneal higher-order aberrations (HOAs) in detecting keratoconus (KC) and suspect keratoconus (SKC). Method: A retrospective, case-control study evaluating non-ectatic (normal) eyes, SKC eyes, and KC eyes. The Sirius Scheimpfug (CSO, Italy) analyses was used to measure HOAs of the anterior and posterior corneal surfaces. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Results: Two-hundred and twenty eyes were included in the analysis (normal n = 108, SKC n = 42, KC n = 70). Receiver operating characteristic (ROC) curve analysis revealed a high predictive ability for anterior corneal HOAs parameters: the root mean square (RMS) total corneal HOAs, RMS trefoil, and RMS coma to detect keratoconus (AUC > 0.9 for all). RMS Coma (3, ±1) derived from the anterior corneal surface was the parameter with the highest ability to discriminate between suspect keratoconus and normal eyes (AUC = 0.922; cut-off > 0.2). All posterior corneal HOAs parameters were unsatisfactory in discriminating between SKC and normal eyes (AUC 0.9 for all except RMS spherical aberrations (AUC = 0.846). Conclusions: Anterior and posterior corneal higher-order aberrations can differentiate between keratoconus and normal eyes, with a high level of certainty. In suspect keratoconus disease, however, only anterior corneal HOAs, and in particular coma-like aberrations, are of value. Corneal aberrometry may be of value in screening for keratoconus in populations with a high prevalence of the disease