7 research outputs found

    The effects of beta-blockers on dobutamine-atropine stress echocardiography: early protocol versus standard protocol

    Get PDF
    BACKGROUND: To study the effects of Beta-blockers during Dobutamine Stress Echocardiography (DSE) comparing the hemodynamic benefits of an early administration of atropine in patients taking or not Beta-blockers. METHODS: One hundred and twenty-one patients were submitted to dobutamine stress echocardiography for the investigation of myocardial ischemia. The administration of atropine was randomized into two groups: A or B (early protocol when atropine was administered at 10 and 20 mcg/kg/min of dobutamine, respectively) and C (standard protocol with atropine at 40 mcg/kg/min of dobutamine). Analysis of the effects of Beta-blockers was done regarding the behavior pattern of heart rate and blood pressure, test time, number of conclusive and inconclusive (negative sub-maximum test) results, total doses of atropine and dobutamine, and general complications. RESULTS: Beta-blocked patients who received early atropine (Group A&B) had a significantly lower double product (p = 0.008), a higher mean test time (p = 0.010) and required a higher dose of atropine (p = 0.0005) when compared to the patients in this group who were not Beta-blocked. The same findings occurred in the standard protocol (Group C), however the early administration of atropine reduced test time both in the presence and absence of this therapy (p = 0.0001). The patients with Beta-blockers in Group A&B had a lower rate of inconclusive tests (26%) compared to those in Group C (40%). Complications were similar in both groups. CONCLUSION: The chronotropic response during dobutamine stress echocardiography was significantly reduced with the use of Beta-blockers. The early administration of atropine optimized the hemodynamic response, reduced test time in patients with or without Beta-blockers and reduced the number of inconclusive tests in the early protocol

    The effects of early administration of atropine during dobutamine stress echocardiography: advantages and disadvantages of early dobutamine-atropine protocol

    No full text
    Abstract Background The conventional dobutamine protocol for the investigation of induced myocardial ischemia is well established. Our objective was to evaluate the effects of early administration of atropine during the dobutamine stress echocardiogram, as compared to its conventional use. Methods One hundred and twenty-one patients were referred to the dobutamine stress echocardiogram, for the investigation of myocardial ischemia and the administration of atropine was randomized into three groups (A, B, C at 10, 20 and 40 mcg/kg/min of dobutamine, respectively). Results The mean level of the double product was significantly lower in the group C patients when compared to group B patients (p = 0.002). The mean test time (12.8 ± 3.1 and 18.7 ± 3.4 p= 0.0001) and the mean total dose of dobutamine (14 × 18 × 25 mg p = 0.008) were significantly higher in group C patients than in group A & B patients. The mean test time was reduced in 6 minutes (31%) with the early administration of atropine in relation to the standard protocol. The atropine dose used in the different groups was similar. Complications were uniform in all cases. Conclusion The early administration of atropine during the dobutamine-atropine stress echocardiography significantly reduces duration of the test and the dose of amine without increasing the number of complications, the total dose of atropine or the number of diagnostic tests.</p

    Congestive heart failure. Correlation between functional class and systolic and diastolic functions assessed by Doppler echocardiography

    No full text
    OBJECTIVE: To evaluate the influence of systolic or diastolic dysfunction, or both on congestive heart failure functional class. METHODS: Thirty-six consecutive patients with a clinical diagnosis of congestive heart failure with sinus rhythm, who were seen between September and November of 1998 answered an adapted questionnaire about tolerance to physical activity for the determination of NYHA functional class. The patients were studied with transthoracic Doppler echocardiography. Two groups were compared: group 1 (19 patients in functional classes I and II) and group 2 (17 patients in functional classes III and IV). RESULTS: The average ejection fraction was significantly higher in group 1 (44.84%±8.04% vs. 32.59%±11.48% with p=0.0007). The mean ratio of the initial/final maximum diastolic filling velocity (E/A) of the left ventricle was significantly smaller in group 1 (1.07±0.72 vs. 1.98±1.49 with p=0.03). The average maximum systolic pulmonary venous velocity (S) was significantly higher in group 1 (53.53cm/s ± 12.02cm/s vs. 43.41cm/s ± 13.55cm/s with p=0.02). The mean ratio of maximum systolic/diastolic pulmonary venous velocity was significantly higher in group 1 (1.52±0.48 vs. 1.08±0.48 with p=0.01). A predominance of pseudo-normal and restrictive diastolic patterns existed in group 2 (58.83% in group 2 vs. 21.06% in group 1 with p=0.03). CONCLUSION: Both the systolic dysfunction index and the patterns of diastolic dysfunction evaluated by Doppler echocardiography worsened with the evolution of congestive heart failure