84 research outputs found

    The key role of smooth impurity potential in formation of hole spectrum for p-Ge/Ge_{1-x}Si_x heterostructures in the quantum Hall regime

    Full text link
    We have measured the temperature (0.1 <= T <= 15 K) and magnetic field (0 <= B <= 12 T) dependences of longitudinal and Hall resistivities for the p-Ge_0.93Si_0.07/Ge multilayers with different Ge layer widths 10 <= d_w <= 38 nm and hole densities p_s = (1-5)10^11 cm^-2. Two models for the long-range random impurity potential (the model with randomly distributed charged centers located outside the conducting layer and the model of the system with a spacer) are used for evaluation of the impurity potential fluctuation characteristics: the random potential amplitude, nonlinear screening length in vicinity of integer filling factors nu = 1 and nu = 2 and the background density of state (DOS). The described models are suitable for explanation of the unusually high value of DOS at nu = 1 and nu = 2, in contrast to the short-range impurity potential models. For half-integer filling factors the linear temperature dependence of the effective QHE plateau-to-plateau transition width nu_0(T) is observed in contrast to scaling behavior for systems with short-range disorder. The finite T -> 0 width of QHE transitions may be due to an effective low temperature screening of smooth random potential owing to Coulomb repulsion of electrons.Comment: Accepted for publication in Nanotechnolog

    Effect of exchange electron-electron interaction on conductivity of InGaAs single and double quantum wells in ballistic regime

    Full text link
    We report an experimental study of quantum conductivity corrections for two-dimensional electron gas in a GaAs/InGaAs/GaAs single and double quantum wells in a wide temperature range (1.8-100) K. We perform a comparison of our experimental data for the longitudinal conductivity at zero magnetic field to the theory of interaction-induced corrections to th transport coefficients. In the temperature range from 10 K up to (45-60) K, wich covers the ballistic interaction regimes for our samples, a rather good agreement between the theory and our experimental results has been found

    Parabolic negative magnetoresistance in p-Ge/Ge1-xSix heterostructures

    Full text link
    Quantum corrections to the conductivity due to the weak localization (WL) and the disorder-modified electron-electron interaction (EEI) are investigated for the high-mobility multilayer p-Ge/Ge1-xSix heterostructures at T = (0.1 - 20.0)K in magnetic field B up to 1.5T. Negative magnetoresistance with logarithmic dependence on T and linear in B^2 is observed for B >= 0.1T. Such a behavior is attributed to the interplay of the classical cyclotron motion and the EEI effect. The Hartree part of the interaction constant is estimated (F_/sigma = 0.44) and the WL and EEI contributions to the total quantum correction /Delta /sigma at B = 0 are separated (/Delta /sigma_{WL} ~ 0.3/Delta /sigma; /Delta /sigma_{EEI} ~ 0.7/Delta /sigma).Comment: 3 pages, 4 figure

    Consideration of the spatial non-uniformity of illumination in the processing of multispectral images

    Full text link
    В статье рассматривается вопрос точности восстановления спектрального коэффициента отражения. Предложен метод минимизации влияния неравномерности освещения в поле кадра на результаты обработки мультиспектральных изображений. Коррекция фотометрических данных в каналах мультиспектрального изображения осуществляется масштабированием по значениям уровней белого и чёрного. Уровень чёрного определяется экстраполяцией тоновых значений нейтральной серой шкалы.The article discusses the question of accuracy of reconstruction of the spectral reflectance. The proposed method minimize the influence of non-uniformity illumination in the field frame on the results of multi-spectral image processing. Correction of photometric data in the channels of the multispectral image is scaling by the values of the black and white levels. The black level is determined by extrapolation of the tonal values of neutral gray scale

    Compensation of spatial and temporal non uniformity of the pulse illumination in multispectral photography

    Full text link
    В статье предлагаются методические улучшения в процесс обработки мультиспектральных изображений, полученных при импульсном освещении. Учитывается влияние как неравномерности освещения, так и нестабильности энергии отдельных импульсов. Уровень «чёрного» определяется по отдельному «чёрному» кадру. Для определения уровня «белого» в исследуемых точках применяется интерполяция вместо фильтрации. Точность восстановления спектрального коэффициента отражения существенно улучшилась по сравнению с рядом предшествующих работ.The article suggests methodological improvements in the processing of multispectral images obtained under pulsed illumination. The effect of non-uniform illumination and the instability of the energy of individual pulses takes into account. The black level is determined by a separate black shot. To determine white level in the examination points, interpolation is applied instead of filtering. The accuracy of the reconstruction of spectral reflectance was significantly improved in comparison with several previous works

    Controlled multispectral led cluster for imaging research

    Full text link
    В статье описан лабораторный осветительный прибор, представляющий собой мультиспектральный кластер на основе стандартных светоизлучающих диодов мощностью 1–3 Вт. Конструкция кластера даёт возможность быстрой замены излучающих компонентов. Спектральный состав излучения кластера может быть легко изменён под конкретную исследовательскую задачу. Управление яркостью компонентов осуществляется автоматизированной системой на основе драйверов с широтно-импульсной модуляцией. Разработанный кластер предназначен для мультиспектральной фотосъёмки и просмотра полиграфических оттисков в процессе колориметрических исследований. В этом случае, с помощью автоматизированной системы управления кластером, могут моделироваться стандартные источники освещения.The article describes laboratory light source, which represents a multi-spectral cluster based on a standard LED with a capacity of 1–3 W. The design of the cluster makes possible fast replacement emitting components. The spectral power distribution of the cluster can be easily modified for a specific research task. Brightness control components is performed with an automated system based on the drivers with pulse width modulation. Developed by the cluster is intended for multi-spectral photography and to view printing images in the process of colorimetric research. In this case, using the automated control system of the cluster can be modeled with standard light sources

    Automated color withholding when adjusting the spectrum of the led cluster

    Full text link
    В статье представлен метод автоматического удержания заданной цветности и яркости освещения, при изменении спектрального состава, создаваемого мультиспектральным светодиодным кластером. С помощью программного обеспечения кластер позволяет из различных комбинаций СИД генерировать спектры, близкие по цветности к стандартным осветителям MKO серии D, регулировать их цветовую температуру и яркость. Экспериментальная проверка показала, что полученная цветность близка к заданной, а дрейф цветности при манипуляциях спектром незначителен. Отклонения сопоставимы общепринятым порогом различимости.The article presents a method for automatically retain the predeter-mined chromaticity and brightness, while changing the spectra of multispectral LED cluster. With the help of the software cluster allows different combinations of LEDs to generate the spectra, similar chroma-ticity to standard CIE illuminants D, and adjust their color temperature and brightness. Experimental verification showed that the chromaticity is close to the specified and drift of color in the spectrum manipulation is small. Deviation comparable to the the generally accepted threshold of noticeability

    The effect of clarification in printing

    Full text link
    Эффект кларификации возникает при специфическом освещении и заключается в увеличении визуально-воспринимаемой насыщенности цветов отражающих объектов. В работе рассмотрены причины возникновения эффекта кларификации. Приведены экспериментальные результаты, говорящие о возможности его направленного использования в полиграфии.The effect of clarification occurs in specific illumination and is to increase a visually-perceived color saturation of the reflective objects. The paper considers the causes of the effect clarification. Experimental results suggesting the possibility of its directional use in the printing industry

    A method for controlling the color rendering index for led RGBW modules

    Full text link
    В статье предложен метод управления яркостями компонентов светодиодных модулей RGBW с использованием широтно-импульсной модуляции. Метод позволяет регулировать значение индекса цветопередачи Ra при фиксированных значениях цветности и общей яркости. Это даёт возможность управлять визуально воспринимаемой насыщенностью зелёных и красных цветов отражающих объектов. Экспериментальная проверка метода показала линейность изменения Ra в зависимости от яркости белого светодиода.This article proposes a method for controlling the components brightness of the RGBW led module using pulse-width modulation. The method allows adjusting the value of color rendering index Ra with fixed values of chromaticity and overall brightness. It`s allows to control visually perceived saturation of the green and red colors of reflective objects. Experimental verification of the method showed linearity Ra changes depending on the brightness of the white led

    Pseudoinverse data processing in multispectral photography for stationary image areas

    Full text link
    Рассматривается вопрос точности простейшего псевдоинверсного метода обработки для реконструкции спектров отражения из экспериментальных данных в мультиспектральной фотосъемке. В качестве основы получаемых решений применяется функциональный базис на основе функций тип интеграла ошибок. Данный подход позволяет отказаться от трудоемкого предварительного исследования оригинала с помощью спектрофотометра. Приводится сравнение с традиционным методом на основе базиса главных компонент по количественным показателям точности решения. Приведено обоснование применимости псевдоинверсного метода для стационарных зон изображений. Показано, что получаемые решения могут обладать высокой точностью и применяться для решения практических задач.Examines the accuracy of a simple pseudoinverse processing method for reconstruction of reflectance spectra from the experimental data in multispectral photography. As the basis of the obtained solutions is applied functional basis based on the function type of Error function. This approach eliminates time-consuming preliminary study of the original with a spectrophotometer. Comparison with the traditional method on the basis of principal components for the quantitative indicators of the accuracy of the solution. Explain the rationale for the applicability of the pseudoinverse method for stationary areas of the image. The obtained solution can have a high accuracy and can be used to solve practical problems
    corecore