1,942 research outputs found

    Nonmonotonic dependence of the absolute entropy on temperature in supercooled Stillinger-Weber silicon

    Full text link
    Using a recently developed thermodynamic integration method, we compute the precise values of the excess Gibbs free energy (G^e) of the high density liquid (HDL) phase with respect to the crystalline phase at different temperatures (T) in the supercooled region of the Stillinger-Weber (SW) silicon [F. H. Stillinger and T. A. Weber, Phys. Rev. B. 32, 5262 (1985)]. Based on the slope of G^e with respect to T, we find that the absolute entropy of the HDL phase increases as its enthalpy changes from the equilibrium value at T \ge 1065 K to the value corresponding to a non-equilibrium state at 1060 K. We find that the volume distribution in the equilibrium HDL phases become progressively broader as the temperature is reduced to 1060 K, exhibiting van-der-Waals (VDW) loop in the pressure-volume curves. Our results provides insight into the thermodynamic cause of the transition from the HDL phase to the low density phases in SW silicon, observed in earlier studies near 1060 K at zero pressure.Comment: This version is accepted for publication in Journal of Statistical Physics (11 figures, 1 table

    Breakup of Shearless Meanders and "Outer" Tori in the Standard Nontwist Map

    Full text link
    The breakup of shearless invariant tori with winding number ω=[0,1,11,1,1,...]\omega=[0,1,11,1,1,...] (in continued fraction representation) of the standard nontwist map is studied numerically using Greene's residue criterion. Tori of this winding number can assume the shape of meanders (folded-over invariant tori which are not graphs over the x-axis in (x,y)(x,y) phase space), whose breakup is the first point of focus here. Secondly, multiple shearless orbits of this winding number can exist, leading to a new type of breakup scenario. Results are discussed within the framework of the renormalization group for area-preserving maps. Regularity of the critical tori is also investigated.Comment: submitted to Chao

    Angular Resolution of an EAS Array for Gamma Ray Astronomy at Energies Greater Than 5 x 10 (13) Ev

    Get PDF
    A 24 detector extensive air shower array is being operated at Ootacamund (2300 m altitude, 11.4 deg N latitude) in southern India for a study of arrival directions of showers of energies greater than 5 x 10 to the 13th power eV. Various configurations of the array of detectors have been used to estimate the accuracy in determination of arrival angle of showers with such an array. These studies show that it is possible to achieve an angular resolution of better than 2 deg with the Ooty array for search for point sources of Cosmic gamma rays at energies above 5 x 10 to the 13th power eV

    Mucous membrane and lower respiratory building related symptoms in relation to indoor carbon dioxide concentrations in the 100-building BASE dataset

    Full text link
    Indoor air pollutants are a potential cause of building related symptoms and can be reduced by increasing ventilation rates. Indoor carbon dioxide (CO 2 ) concentration is an approximate surrogate for concentrations of occupant-generated pollutants and for ventilation rate per occupant. Using the US EPA 100 office-building BASE Study dataset, we conducted multivariate logistic regression analyses to quantify the relationship between indoor CO 2 concentrations (dCO 2 ) and mucous membrane (MM) and lower respiratory system (LResp) building related symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. In addition, we tested the hypothesis that certain environmentally mediated health conditions (e.g., allergies and asthma) confer increased susceptibility to building related symptoms. Adjusted odds ratios (ORs) for statistically significant, dose–dependent associations ( P <  0.05) for combined mucous membrane, dry eyes, sore throat, nose/sinus congestion, sneeze, and wheeze symptoms with 100 p.p.m. increases in dCO 2 ranged from 1.1 to 1.2. Building occupants with certain environmentally mediated health conditions were more likely to report that they experience building related symptoms than those without these conditions (statistically significant ORs ranged from 1.5 to 11.1, P  < 0.05).Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73439/1/j.1600-0668.2004.00298.x.pd
    corecore