15 research outputs found

    Quality of Communication in Robotic Surgery and Surgical Outcomes

    Get PDF
    Robotic surgery has introduced unique challenges to surgical workflow. The association between quality of communication in robotic-assisted laparoscopic surgery and surgical outcomes was evaluated

    Robotic Trachelectomy After Supracervical Hysterectomy for Benign Gynecologic Disease

    Get PDF
    A renewed interest in the supra cervical approach to hysterectomy has created a cohort of patients with a retained cervix at risk of persistent symptoms requiring a subsequent trachelectomy. The objective of this study was to evaluate the efficacy of robotic trachelectomy after a previous supracervical hysterectomy

    A hybrid Delphi-AHP multi-criteria analysis of Moving Block and Virtual Coupling railway signalling

    Get PDF
    The railway industry needs to investigate overall impacts of next generation signalling systems such as Moving Block (MB) and Virtual Coupling (VC) to identify development strategies to face the forecasted railway demand growth. To this aim an innovative multi-criteria analysis (MCA) framework is introduced to analyse and compare VC and MB in terms of relevant criteria including quantitative (e.g. costs, capacity, stability, energy) and qualitative ones (e.g. safety, regulatory approval). We use a hybrid Delphi-Analytic Hierarchic Process (AHP) technique to objectively select, combine and weight the different criteria to more reliable MCA outcomes. The analysis has been performed for different rail market segments including high-speed, mainline, regional, urban and freight corridors. The results show that there is a highly different technological maturity level between MB and VC given the larger number of vital issues not yet solved for VC. The MCA also indicates that VC could outperform MB for all market segments if it reaches a comparable maturity and safety level. The provided analysis can effectively support the railway industry in strategic investment planning of VC

    The impact of a wireless audio system on communication in robotic-assisted laparoscopic surgery: A prospective controlled trial.

    Get PDF
    BACKGROUND: Robotic surgery presents a challenge to effective teamwork and communication in the operating theatre (OR). Our objective was to evaluate the effect of using a wireless audio headset device on communication, efficiency and patient outcome in robotic surgery. METHODS AND FINDINGS: A prospective controlled trial of team members participating in gynecologic and urologic robotic procedures between January and March 2015. In the first phase, all surgeries were performed without headsets (control), followed by the intervention phase where all team members used the wireless headsets. Noise levels were measured during both phases. After each case, all team members evaluated the quality of communication, performance, teamwork and mental load using a validated 14-point questionnaire graded on a 1-10 scale. Higher overall scores indicated better communication and efficiency. Clinical and surgical data of all patients in the study were retrieved, analyzed and correlated with the survey results. The study included 137 procedures, yielding 843 questionnaires with an overall response rate of 89% (843/943). Self-reported communication quality was better in cases where headsets were used (113.0 ± 1.6 vs. 101.4 ± 1.6; p \u3c .001). Use of headsets reduced the percentage of time with a noise level above 70 dB at the console (8.2% ± 0.6 vs. 5.3% ± 0.6, p \u3c .001), but had no significant effect on length of surgery nor postoperative complications. CONCLUSIONS: The use of wireless headset devices improved quality of communication between team members and reduced the peak noise level in the robotic OR

    Minimally invasive surgery in pelvic floor repair.

    No full text
    PURPOSE OF REVIEW: To review the use and efficacy of minimally invasive surgery in pelvic organ prolapse (POP) repair. This review summarizes surgical options for management of POP with special emphasis on minimally invasive surgical approach and discusses the recent experience and feasibility of integrating robot-assisted technology. RECENT FINDINGS: Minimally invasive approaches have equal efficacy and less morbidity than laparotomy for POP repair, particularly apical prolapse. Robotics may facilitate the rate of minimally invasive surgery for POP repair with greater cost and as yet no proven superiority for conventional laparoscopy. SUMMARY: Minimally invasive surgery is the preferred approach to POP repair. Conventional laparoscopic or robotic sacral colpopexy is recommended for apical defect and procidentia

    Quality of Communication in Robotic Surgery and Surgical Outcomes.

    Get PDF
    BACKGROUND AND OBJECTIVES: Robotic surgery has introduced unique challenges to surgical workflow. The association between quality of communication in robotic-assisted laparoscopic surgery and surgical outcomes was evaluated. METHODS: After each gynecologic robotic surgery, the team members involved in the surgery completed a survey regarding the quality of communication. A composite quality-of-communication score was developed using principal component analysis. A higher composite quality-of-communication score signified poor communication. Objective parameters, such as operative time and estimated blood loss (EBL), were gathered from the patient\u27s medical record and correlated with the composite quality-of-communication scores. RESULTS: Forty robotic cases from March through May 2013 were included. Thirty-two participants including surgeons, circulating nurses, and surgical technicians participated in the study. A higher composite quality-of-communication score was associated with greater EBL (P = .010) and longer operative time (P = .045), after adjustment for body mass index, prior major abdominal surgery, and uterine weight. Specifically, for every 1-SD increase in the perceived lack of communication, there was an additional 51 mL EBL and a 31-min increase in operative time. The most common reasons reported for poor communication in the operating room were noise level (28/36, 78%) and console-to-bedside communication problems (23/36, 64%). CONCLUSION: Our study demonstrates a significant association between poor intraoperative team communication and worse surgical outcomes in robotic gynecologic surgery. Employing strategies to decrease extraneous room noise, improve console-to-bedside communication and team training may have a positive impact on communication and related surgical outcomes

    Robotic Trachelectomy After Supracervical Hysterectomy for Benign Gynecologic Disease.

    Get PDF
    BACKGROUND AND OBJECTIVES: A renewed interest in the supra cervical approach to hysterectomy has created a cohort of patients with a retained cervix at risk of persistent symptoms requiring a subsequent trachelectomy. The objective of this study was to evaluate the efficacy of robotic trachelectomy after a previous supracervical hysterectomy. METHODS: This is a retrospective chart review of women who had robotic trachelectomy after supracervical hysterectomy for benign gynecologic disease from January 2009 through October 2014. RESULTS: Eleven patients underwent robotic trachelectomy for benign conditions during the observed period. Prior supracervical hysterectomy had been performed for pelvic pain (8/11, 73%), abnormal uterine bleeding (7/11, 64%), and dysmenorrhea (5/11, 45%). In 10 of 11 patients, the symptoms leading to robotic trachelectomy were the same as those leading to supracervical hysterectomy. The time from hysterectomy to recurrence of symptoms ranged from 0.5 to 26 months (median, 6), whereas the time interval from previous surgery to robotic trachelectomy ranged from 1 to 57 months (median, 26). Mean age and body mass index at robotic trachelectomy were 42 ± 5.4 years and 32 ± 6.1 kg/m(2). Mean length of surgery was 218 ± 88 minutes (range, 100-405). There was 1 major postoperative complication involving bladder perforation and subsequent vesicovaginal fistula (VVF). Endometriosis was seen in 27% of pathologic specimens and cervicitis in another 27%; 45% showed normal tissue histology. In 6 (55%) cases, symptoms leading to trachelectomy resolved completely after surgery, and the other 5 (45%) patients reported a significant improvement. CONCLUSIONS: Although trachelectomy can be a challenging surgery, our experience suggests that the robotic approach may be a valuable means of achieving safe and reproducible outcomes

    Long-term outcomes for different vaginal cuff closure techniques in robotic-assisted laparoscopic hysterectomy: A randomized controlled trial.

    No full text
    OBJECTIVE: This randomized controlled trial aimed to evaluate the outcomes of different vaginal cuff closure techniques in robotic-assisted total laparoscopic hysterectomy. STUDY DESIGN: Ninety women undergoing robotic-assisted total laparoscopic hysterectomy for benign disease were randomized to three vaginal cuff closure techniques: running 2.0 V-Lock™ (Arm 1), 0 Vicryl™ figure-of-eight (Arm 2), and running 0 Vicryl™ with Lapra-Ty ® (Arm 3). Patients’ records were reviewed for age, body mass index, smoking status and relevant co-morbidities. Operative times for vaginal closure and total length of surgery, estimated blood loss, and peri-operative complications were collected. Patients were evaluated at 2 and 6 weeks post-operatively, and interviewed 1 year following surgery by a telephone survey. Outcomes evaluated were vaginal cuff dehiscence, pain, dyspareunia and bleeding. RESULTS: The study arms did not differ with respect to estimated blood loss (50mL in each arm; p=0.34), median vaginal cuff closure time (14.5, 12 and 13min, respectively; p=0.09) or readmission (p=0.55). In the 1-year follow-up (54/90 respondents; 60%), there were no significant differences among study arms for vaginal bleeding, cuff infection or dyspareunia. Only women belonging to arm 3 reported vaginal pain (0%, 0% and 23%, respectively; p=0.01). No cases of vaginal cuff dehiscence were observed. CONCLUSIONS: The type of closure technique has no significant impact on patient outcomes. In the absence of a clear advantage of one technique over the others, the decision regarding the preferred method to close the vaginal cuff in robotic-assisted total laparoscopic hysterectomy should be based on surgeons\u27 preference and cost effectiveness

    The impact of a wireless audio system on communication in robotic-assisted laparoscopic surgery: A prospective controlled trial.

    No full text
    BACKGROUND:Robotic surgery presents a challenge to effective teamwork and communication in the operating theatre (OR). Our objective was to evaluate the effect of using a wireless audio headset device on communication, efficiency and patient outcome in robotic surgery. METHODS AND FINDINGS:A prospective controlled trial of team members participating in gynecologic and urologic robotic procedures between January and March 2015. In the first phase, all surgeries were performed without headsets (control), followed by the intervention phase where all team members used the wireless headsets. Noise levels were measured during both phases. After each case, all team members evaluated the quality of communication, performance, teamwork and mental load using a validated 14-point questionnaire graded on a 1-10 scale. Higher overall scores indicated better communication and efficiency. Clinical and surgical data of all patients in the study were retrieved, analyzed and correlated with the survey results. The study included 137 procedures, yielding 843 questionnaires with an overall response rate of 89% (843/943). Self-reported communication quality was better in cases where headsets were used (113.0 ± 1.6 vs. 101.4 ± 1.6; p < .001). Use of headsets reduced the percentage of time with a noise level above 70 dB at the console (8.2% ± 0.6 vs. 5.3% ± 0.6, p < .001), but had no significant effect on length of surgery nor postoperative complications. CONCLUSIONS:The use of wireless headset devices improved quality of communication between team members and reduced the peak noise level in the robotic OR
    corecore