13,362 research outputs found

    Theoretical studies of Si and GaAs surfaces and initial steps in the oxidation

    Get PDF
    Using ab initio quantum chemical methods (generalized valence bond), we examine (i) the electronic states of Si (111) and GaAs (110) surface, (ii) the relaxation of the Si (111) surface, (iii) the reconstruction of the GaAs surface, (iv) the initial steps in the chemisorption of O_2 on Si (111), and (v) the bonding of O atom to Ga and As centers

    Equivariant Poincar\'e series of filtrations and topology

    Full text link
    Earlier, for an action of a finite group GG on a germ of an analytic variety, an equivariant GG-Poincar\'e series of a multi-index filtration in the ring of germs of functions on the variety was defined as an element of the Grothendieck ring of GG-sets with an additional structure. We discuss to which extend the GG-Poincar\'e series of a filtration defined by a set of curve or divisorial valuations on the ring of germs of analytic functions in two variables determines the (equivariant) topology of the curve or of the set of divisors

    Perfect Quantum Privacy Implies Nonlocality

    Full text link
    Private states are those quantum states from which a perfectly secure cryptographic key can be extracted. They represent the basic unit of quantum privacy. In this work we show that all states belonging to this class violate a Bell inequality. This result establishes a connection between perfect privacy and nonlocality in the quantum domain.Comment: 4 pages, published versio

    Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

    Get PDF
    In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an 241Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program

    Optimal MRI sequences for 68Ga-PSMA-11 PET/MRI in evaluation of biochemically recurrent prostate cancer.

    Get PDF
    BackgroundPET/MRI can be used for the detection of disease in biochemical recurrence (BCR) patients imaged with 68Ga-PSMA-11 PET. This study was designed to determine the optimal MRI sequences to localize positive findings on 68Ga-PSMA-11 PET of patients with BCR after definitive therapy. Fifty-five consecutive prostate cancer patients with BCR imaged with 68Ga-PSMA-11 3.0T PET/MRI were retrospectively analyzed. Mean PSA was 7.9 Â± 12.9 ng/ml, and mean PSA doubling time was 7.1 Â± 6.6 months. Detection rates of anatomic correlates for prostate-specific membrane antigen (PSMA)-positive foci were evaluated on small field of view (FOV) T2, T1 post-contrast, and diffusion-weighted images. For prostate bed recurrences, the detection rate of dynamic contrast-enhanced (DCE) imaging for PSMA-positive foci was evaluated. Finally, the detection sensitivity for PSMA-avid foci on 3- and 8-min PET acquisitions was compared.ResultsPSMA-positive foci were detected in 89.1% (49/55) of patients evaluated. Small FOV T2 performed best for lymph nodes and detected correlates for all PSMA-avid lymph nodes. DCE imaging performed the best for suspected prostate bed recurrence, detecting correlates for 87.5% (14/16) of PSMA-positive prostate bed foci. The 8-min PET acquisition performed better than the 3-min acquisition for lymph nodes smaller than 1 cm, detecting 100% (57/57) of lymph nodes less than 1 cm, compared to 78.9% (45/57) for the 3-min acquisition.ConclusionPSMA PET/MRI performed well for the detection of sites of suspected recurrent disease in patients with BCR. Of the MRI sequences obtained for localization, small FOV T2 images detected the greatest proportion of PSMA-positive abdominopelvic lymph nodes and DCE imaging detected the greatest proportion of PSMA-positive prostate bed foci. The 8-min PET acquisition was superior to the 3 min acquisition for detection of small lymph nodes

    Mott insulator model of the Si(111)–(2×1) surface

    Get PDF
    Theoretical cluster calculations for the Si(111)–(2×1) surface lead to a description in which there is a singly occupied dangling bond on each surface atom. These orbitals are weakly coupled, forming a nondegenerate, nonmetallic two-dimensional Mott insulator, a description involving very strong electron correlation effects. Strong experimental support for this Mott insulator description is provided by (i) the magnitude of Si(2p) core level shifts, (ii) the dispersion of the dangling bond energy bands, and (iii) the absolute ionization potential from the dangling bond levels

    2+1 flavor domain wall QCD on a (2 fm)^3 lattice: light meson spectroscopy with Ls = 16

    Full text link
    We present results for light meson masses and pseudoscalar decay constants from the first of a series of lattice calculations with 2+1 dynamical flavors of domain wall fermions and the Iwasaki gauge action. The work reported here was done at a fixed lattice spacing of about 0.12 fm on a 16^3\times32 lattice, which amounts to a spatial volume of (2 fm)^3 in physical units. The number of sites in the fifth dimension is 16, which gives m_{res} = 0.00308(4) in these simulations. Three values of input light sea quark masses, m_l^{sea} \approx 0.85 m_s, 0.59 m_s and 0.33 m_s were used to allow for extrapolations to the physical light quark limit, whilst the heavier sea quark mass was fixed to approximately the physical strange quark mass m_s. The exact rational hybrid Monte Carlo algorithm was used to evaluate the fractional powers of the fermion determinants in the ensemble generation. We have found that f_\pi = 127(4) MeV, f_K = 157(5) MeV and f_K/f_\pi = 1.24(2), where the errors are statistical only, which are in good agreement with the experimental values.Comment: RBC and UKQCD Collaborations. 17 pages, 14 figures. Typeset with ReVTEX4. v2: replaced with the version published in PRD with improved introductio
    • …
    corecore