3 research outputs found

    Outcomes of patients after successful left ventricular assist device explantation: a EUROMACS study

    No full text
    AIMS: Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1-2% of the cases. However, follow-up data about this condition are scarcely available in the literature. This study aimed to report the long-term outcomes and clinical management following LVAD explantation. METHODS AND RESULTS: An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre-implant characteristics were retrieved and compared with the non-recovery patients. The follow-up data after explantation were collected via a questionnaire. A Kaplan-Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow-up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter-quartile range: 29-52), and 23 (82%) were male. Baseline left ventricular ejection fraction was 18% (inter-quartile range: 10-20%), and 60.7% of the patients had Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2. Aetiologies of HF were dilated cardiomyopathy in 36%, myocarditis in 32%, and ischaemic in 14% of the patients, and 18% had miscellaneous aetiologies. The devices implanted were HeartMate II in 14 (50%), HVAD in 11 (39%), HeartMate 3 in 2 (7%), and 1 unknown with a median duration of support of 410 days (range: 59-1286). The median follow-up after explantation was 26 months (range 0.3-73 months), and 82% of the patients were in New York Heart Association Class I or II. Beta-blockers were prescribed to 85%, angiotensin-converting enzyme inhibitors to 71%, and loop diuretics to 50% of the patients, respectively. Freedom from the composite endpoint was 100% after 30 days and 88% after 2 years. CONCLUSIONS: The survival after LVAD explantation is excellent without the need for heart transplantation or LVAD reimplantation. Only a minority of the patients suffer from a relapse of significant HF.status: publishe

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): second EUROMACS Paediatric (Paedi-EUROMACS) report

    No full text
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months continue to be low (33.2%) The fact that the EUROMACS registry is embedded within the European Association for Cardio-Thoracic Surgery Quality Improvement Programme offers opportunities to focus on improving outcomes.status: publishe
    corecore