6 research outputs found

    Vertebral Body Stapling versus Bracing for Patients with High-Risk Moderate Idiopathic Scoliosis.

    Get PDF
    Purpose. We report a comparison study of vertebral body stapling (VBS) versus a matched bracing cohort for immature patients with moderate (25 to 44°) idiopathic scoliosis (IS). Methods. 42 of 49 consecutive patients (86%) with IS were treated with VBS and followed for a minimum of 2 years. They were compared to 121 braced patients meeting identical inclusion criteria. 52 patients (66 curves) were matched according to age at start of treatment (10.6 years versus 11.1 years, resp. [P = 0.07]) and gender. Results. For thoracic curves 25-34°, VBS had a success rate (defined as curve progressio

    Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make?

    No full text
    The use of thoracic pedicle screws for the treatment of adolescent idiopathic scoliosis (AIS) has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges, and surgeons experience a learning curve. The in vivo accuracy as determined by computed tomography (CT) of placement of thoracic pedicle screws in the deformed spine as a function of surgeon experience is unknown. We undertook a retrospective review to determine the effect of surgeon experience on the accuracy of thoracic pedicle screw placement in AIS. In 2005, we started to obtain routine postoperative CT scans on patients undergoing a spinal fusion. From a database of these patients, we selected AIS patients, who underwent a posterior spinal fusion. Fifteen consecutive patients for each of the following three groups stratified by attending surgeon experience were selected (N = 45): A) less than 20 cases of all pedicle screw constructs for AIS (surgeons <2 years of practice), B) 20–50 cases (surgeons 2–5 years of practice), and C) greater than 50 cases (surgeons greater than 5 years of practice). Intraoperative evaluation of all screws included probing of the pedicle screw tract, neurophysiologic monitoring, and fluoroscopic confirmation. A total of 856 thoracic pedicle screws were studied. Postoperative CT scans were evaluated by two spine surgeons and a consensus read established as follows: (1) In: intraosseous placement or ≤2-mm breach, (2) Out: >2-mm breach, either medial or lateral. Of the 856 screws, 104 demonstrated a >2-mm breach, for an overall rate of 12.1% (medial = 55, lateral = 49, P = 0.67). When the breach rates were stratified by surgeon experience, there was a trend toward decreased rate of breach for the most experienced surgeons, although this did not attain statistical significance (Group A: 12.7%, Group B: 12.9%, Group C: 10.8%, P = 0.58). However, the most experienced group (C) had a markedly decreased rate of medial breaches (3.5 vs. 7.4% and 8.4% for groups A and B, respectively, P < 0.01). The breach rate for the concave periapical screws was not statistically different from the overall breach rate (13.0% vs. 12.1%, P = 0.93). In conclusion, the overall accuracy of placement of pedicle screws in the deformed spine was 87.9%, with no neurologic, vascular, or visceral complications. Meticulous technique allows spine surgeons with a range of surgical experience to accurately and safely place thoracic pedicle screws in the deformed spine. The most experienced surgeons demonstrated the lowest rate of medial breaches

    Hyaluronan concentration and size distribution in human knee synovial fluid: variations with age and cartilage degeneration

    Get PDF
    BACKGROUND: One potential mechanism for early superficial cartilage wear in normal joints is alteration of the lubricant content and quality of synovial fluid. The purpose of this study was to determine if the concentration and quality of the lubricant, hyaluronan, in synovial fluid: (1) was similar in left and right knees; (2) exhibited similar age-associated trends, whether collected postmortem or antemortem; and (3) varied with age and grade of joint degeneration. METHODS: Human synovial fluid of donors (23–91 years) without osteoarthritis was analyzed for the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5–7 MDa, 1–2.5 MDa, 0.5–1 MDa, and 0.03–0.5 MDa. Similarity of data between left and right knees was assessed by reduced major axis regression, paired t-test, and Bland-Altman analysis. The effect of antemortem versus postmortem collection on biochemical properties was assessed for age-matched samples by unpaired t-test. The relationships between age, joint grade, and each biochemical component were assessed by regression analysis. RESULTS: Joint grade and the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5–7 MDa, 1–2.5 MDa, and 0.5–1 MDa in human synovial fluid showed good agreement between left and right knees and were similar between age-matched patient and cadaver knee joints. There was an age-associated decrease in overall joint grade (–15 %/decade) and concentrations of hyaluronan (–10.5 %/decade), and hyaluronan in the molecular weight ranges of 2.5–7 MDa (–9.4 %/decade), 1–2.5 MDa (–11.3 %/decade), 0.5–1 MDa (–12.5 %/decade), and 0.03–0.5 MDa (–13.0 %/decade). Hyaluronan concentration and quality was more strongly associated with age than with joint grade. CONCLUSIONS: The age-related increase in cartilage wear in non-osteoarthritic joints may be related to the altered hyaluronan content and quality of synovial fluid
    corecore