21 research outputs found

    50 Years of Heart Valve Replacement: Effect of Prosthesis Choice on Long-Term Outcomes

    No full text

    Continuous Monitoring of Risk-Adjusted Outcomes: Excess Deaths vs. Lives Saved.

    No full text
    Reporting of risk-adjusted surgical outcomes is commonly used to compare providers and track changes over time. Preferred graphical methods use the relationship of the observed to the expected values of outcome events, including their ratio (O/E), cumulative sum (CUSUM) of their differences over time, called Risk-Adjusted CUSUM (RA-CUSUM) or Variable Life Adjusted Display (VLAD). We demonstrate these methods using operative mortality data for 7,255 isolated coronary artery bypass graft patients from January 2014 to June 2017. RA-CUSUM and VLAD are excellent techniques to display risk-adjusted outcomes and, unlike O/E, can provide continuous monitoring as performance varies over time

    Bioprosthetic Aortic Valve Durability: A Meta-Regression of Published Studies.

    No full text
    To compare structural valve deterioration (SVD) among bioprosthetic aortic valve types, a PubMed search found 54 papers containing SVD-free curves extending to at least 10 years. The curves were digitized and fit to Weibull distributions, and the mean times to valve failure (MTTF) were calculated. Twelve valve models were collapsed into four valve types: Medtronic (Medtronic, Minneapolis, MN) and Edwards (Edwards Lifesciences, Irvine, CA) porcine; and Sorin (Sorin Group [now LivaNova], London, United Kingdom) and Edwards pericardial. Meta-regression found MTTF was associated with the patient\u27s age, publication year, SVD definition, and valve type. Sorin pericardial valves had significantly lower risk-adjusted MTTF (higher SVD risk), and there were no significant differences in MTTF among the other three valve types

    Correlation of Electrophysiological Activation Patterns to Tension Generation in Stimulated Latissimus Dorsi Muscle

    No full text
    Skeletal muscle has been used for biomechanical assist in experimental and clinical studies. Central to the success of these procedures is the generation of sufficient muscle force for the lifetime of the subject. Burst (tetanic) stimulation results in summation of individual twitches and generates higher power output. However, the superiority of paraneural versus intramuscular as well as proximal versus middle and distal intramuscular stimulations remains unclear. Electrophysiological mapping and mechanical performance of seven canine latissimus dorsi muscles were analyzed. The mechanism of higher tension generation produced by: (1) increased temporal summation; (2) greater motor units activated; or (3) result of both were determined. The parameters primarily dependent on the number of activated motor units are significantly greater following paraneural and proximal intramuscular stimulations. The parameters mainly related to temporal summation are not different between various electrode configurations. For intramuscular stimulation, it is the location of interelectrode field rather than the location of the cathode perse that determines the mechanical performance of the skeletal muscle. Furthermore, tension development of skeletal muscle is primary nerve activation rather than direct muscle stimulation. The higher tension generation that resulted from different electrode configurations is produced by activating a higher number of muscle fibers through the neuromuscular junctions

    Does Tight Glucose Control Prevent Myocardial Injury and Inflammation?

    No full text
    Hyperglycemia has been postulated to be cardiotoxic. We addressed the hypothesis that uncontrolled blood glucose induces myocardial damage in diabetic patients undergoing isolated coronary artery bypass graft surgery receiving continuous insulin infusion in the immediate postoperative period. Our primary aim was to assess the degree of tight glycemic control for each patient and to link the degree of glycemic control to intermediate outcome of myocardial damage. We prospectively enrolled 199 consecutive patients with diabetes undergoing isolated coronary artery bypass graft surgery from October 2003 through August 2005. Preoperative hemoglobin A1c and glucose measures were collected from the surgical admission. We measured biomarkers of myocardial damage (cardiac troponin I) and metabolic dysfunction (blood glucose and hemoglobin A1c) to identify a difference among patients under tight (90–100% of glucose measures ≤150 mg/dL) or loose (<90%) glycemic control. All patients received continuous insulin infusion in the immediate postoperative period. We discovered 45.6% of the patients were in tight control. We found tight glycemic control resulted in no significant difference in troponin I release. Mean cardiac troponin I for tight and loose control was 4.9 and 8.5 (ng/mL), p value .3. We discovered patients varied with their degree of control, even with established protocols to maintain glucose levels within the normal range. We were unable to verify tight glycemic control compared to loose control was significantly associated with decreased cardiac troponin I release. Future studies are needed to evaluate the cardiotoxic mechanisms of hyperglycemia postulated in this study
    corecore