17 research outputs found
Time Dependent Theory for Random Lasers
A model to simulate the phenomenon of random lasing is presented. It couples
Maxwell's equations with the rate equations of electronic population in a
disordered system. Finite difference time domain methods are used to obtain the
field pattern and the spectra of localized lasing modes inside the system. A
critical pumping rate exists for the appearance of the lasing
peaks. The number of lasing modes increase with the pumping rate and the length
of the system. There is a lasing mode repulsion. This property leads to a
saturation of the number of modes for a given size system and a relation
between the localization length and average mode length .Comment: 8 pages. Send to PR
Urinary ATP as an indicator of infection and inflammation of the urinary tract in patients with lower urinary tract symptoms
BACKGROUND:
Adenosine-5'-triphosphate (ATP) is a neurotransmitter and inflammatory cytokine implicated in the pathophysiology of lower urinary tract disease. ATP additionally reflects microbial biomass thus has potential as a surrogate marker of urinary tract infection (UTI). The optimum clinical sampling method for ATP urinalysis has not been established. We tested the potential of urinary ATP in the assessment of lower urinary tract symptoms, infection and inflammation, and validated sampling methods for clinical practice.
METHODS:
A prospective, blinded, cross-sectional observational study of adult patients presenting with lower urinary tract symptoms (LUTS) and asymptomatic controls, was conducted between October 2009 and October 2012. Urinary ATP was assayed by a luciferin-luciferase method, pyuria counted by microscopy of fresh unspun urine and symptoms assessed using validated questionnaires. The sample collection, storage and processing methods were also validated.
RESULTS:
75 controls and 340 patients with LUTS were grouped as without pyuria (n = 100), pyuria 1-9 wbc ?l(-1) (n = 120) and pyuria ?10 wbc ?l(-1) (n = 120). Urinary ATP was higher in association with female gender, voiding symptoms, pyuria greater than 10 wbc ?l(-1) and negative MSU culture. ROC curve analysis showed no evidence of diagnostic test potential. The urinary ATP signal decayed with storage at 23°C but was prevented by immediate freezing at ??-20°C, without boric acid preservative and without the need to centrifuge urine prior to freezing.
CONCLUSIONS:
Urinary ATP may have a role as a research tool but is unconvincing as a surrogate, clinical diagnostic marker
Lasers
An introductory text on laser physics features an emphasis on basic laser principles and theory, without requiring a quantum mechanical background
Experimental Demonstration Of Gain Guided Lasing In An Index Anti-Guiding Large Mode Area Fiber
Recent observations of apparently single mode gain-guided lasing in Nd3+ fibers with 100 μm diameter index anti-guided cores demonstrate the potential of gain guiding for single mode fiber lasers with very large mode areas. © 2007 Optical Society of America