    Six weeks Use of a Wearable Soft-robotic Glove During ADL:Preliminary Results of Ongoing Clinical Study

    Get PDF
    In this ongoing study, an assistive wearable soft-robotic glove, named Carbonhand, is tested at home for 6 weeks by subjects with decreased handgrip strength to receive a first insight in the therapeutic effect of using this assistive grip-supporting glove during ADLs. Preliminary results of the first 13 participants showed that participants appreciated use of the glove to assist them with daily life activities. Even more, grip strength without glove improved and functional performance showed increases as well. These preliminary findings hold promise for observing a clinical effect of using the soft-robotic glove as assistance in ADLs upon completion of data collection

    Women’s experiences of wearing therapeutic footwear in three European countries

    Get PDF
    Background: Therapeutic footwear is recommended for those people with severe foot problems associated with rheumatoid arthritis (RA). However, it is known that many do not wear them. Although previous European studies have recommended service and footwear design improvements, it is not known if services have improved or if this footwear meets the personal needs of people with RA. As an earlier study found that this footwear has more impact on women than males, this study explores women’s experiences of the process of being provided with it and wearing it. No previous work has compared women’s experiences of this footwear in different countries, therefore this study aimed to explore the potential differences between the UK, the Netherlands and Spain. Method: Women with RA and experience of wearing therapeutic footwear were purposively recruited. Ten women with RA were interviewed in each of the three countries. An interpretive phenomenological approach (IPA) was adopted during data collection and analysis. Conversational style interviews were used to collect the data. Results: Six themes were identified: feet being visibly different because of RA; the referring practitioners’ approach to the patient; the dispensing practitioners’ approach to the patient; the footwear being visible as different to others; footwear influencing social participation; and the women’s wishes for improved footwear services. Despite their nationality, these women revealed that therapeutic footwear invokes emotions of sadness, shame and anger and that it is often the final and symbolic marker of the effects of RA on self perception and their changed lives. This results in severe restriction of important activities, particularly those involving social participation. However, where a patient focussed approach was used, particularly by the practitioners in Spain and the Netherlands, the acceptance of this footwear was much more evident and there was less wastage as a result of the footwear being prescribed and then not worn. In the UK, the women were more likely to passively accept the footwear with the only choice being to reject it once it had been provided. All the women were vocal about what would improve their experiences and this centred on the consultation with both the referring practitioner and the practitioner that provides the footwear. Conclusion: This unique study, carried out in three countries has revealed emotive and personal accounts of what it is like to have an item of clothing replaced with an ‘intervention’. The participant’s experience of their consultations with practitioners has revealed the tension between the practitioners’ requirements and the women’s ‘social’ needs. Practitioners need greater understanding of the social and emotional consequences of using therapeutic footwear as an intervention

    Assessment of a two-channel implantable peroneal nerve stimulator post-stroke

    Get PDF
    Thesis outline and aims: to progress towards evidence based application of PNS to improve lower extremity function, the aim of the present thesis is to evaluate an implantable two-channel peroneal nerve stimulator versus conventional splinting as a treatment option for chronic stroke patients with a dropped foot. In chapter 2 a systematic review is described on the available evidence on the improvement of walking in stroke patients with a dropped foot when using PNS. Trials were identified that investigated the orthotic effect of FES on walking. All included studies were scored on methodological quality and studies that measured walking speed were pooled and a pooled difference including confidence interval was calculated. The review concludes that PNS seems to have a positive orthotic effect on walking speed in stroke patients with a dropped foot

    La mujer como ser histórico y cultural

    Get PDF
    Los años bajo la dictadura del General Franco desde 1939 a 1975, constituyeron un periodo donde ser mujer significaba la subyugación a maridos o padres, una educación segregada y enfocada siempre al servilismo, la implantación y establecimiento de la denominada 'Sección Femenina', donde cobraban mayor importancia coser y bordar que estudiar otras materias consideradas masculinas. La necesidad de un consentimiento marital para poder realizar algunos trámites burocráticos, la inexistente capacidad legal de la mujer para decidir en ciertos temas de salud o la precaria planificación familiar eran aspectos habituales de la vida cotidiana de las mujeres. Éstos son sólo algunos ejemplos de la innumerable lista que llenaba el significado de ser mujer en ese contexto histórico; pero en ninguno de estos puntos a enumerar encontraríamos trazas, ni atisbos, de autonomía o libertad como género, como mujeres, o evidentemente tampoco como parturientas. Afortunadamente, en la actualidad la mujer puede expresar sus preferencias, necesidades, deseos y expectativas sobre el proceso del parto y nacimiento mediante su "plan de parto"

    Measuring Quality of Life in Stroke Subjects Receiving an Implanted Neural Prosthesis for Drop Foot

    Get PDF
    The aim was to determine if the treatment of a drop foot by means of an implantable two-channel peroneal nerve stimulator improves health-related quality of life (HRQoL). All subjects were measured at baseline and after a follow-up period of 12 and 26 weeks. Twenty-nine stroke survivors with chronic hemiplegia with drop foot who fulfilled the predefined inclusion and exclusion criteria were included in the present randomized controlled trial. The intervention group received an implantable two-channel peroneal nerve stimulator for correction of their drop foot. The control group continued using their conventional walking device, consisting of an ankle-foot orthosis, orthopedic shoes, or no device. HRQoL was assessed in two different ways: (i) by taking descriptive measures, that is, the Short Form-36 (SF-36; generic measure) and the Disability Impact Profile (DIP; specific measure); and (ii) by obtaining preference-based utilities both measured with the time trade-off (direct way) and by calculating them from the EuroQol (EQ-5D) and SF-36. A significant positive effect of the implantable device was found on the physical functioning domain, the general health domain, and the physical component summary score of the SF-36. For the DIP, a significant improvement was found on the domains mobility, self-care, and psychological status in the intervention group. Regarding the preference-based utility measures, a significant effect was found for the utility index calculated from the EQ-5D. The implantable two-channel peroneal nerve stimulator seems to be efficient to improve HRQoL, mainly the domains related to physical functioning. A relation was present between the utility indexes calculated from the EQ-5D and SF-36.\ud \u

    The Sensitivity and Selectivity of an Implantable Two-Channel Peroneal Nerve Stimulator System for Restoration of Dropped Foot

    Get PDF
    The objective of this study was to evaluate the stimulation responses on each channel of an implantable two-channel stimulator that stimulates the peroneal nerve branches innervating the muscles for dorsiflexion and eversion movements. Currently five Dutch patients and five English patients have been implanted with this system. Isometric ankle torque measurements were carried out in the patient with the longest follow-up period (1 y). A force sensor measured the three components of moment generated at the ankle joint. Stimulation intensity can be adjusted with great accuracy. Dorsiflexion moments are almost entirely determined by the setting of channel 1. Eversion moments are determined mainly by channel 2 and to a lesser extent by channel 1. Both channels determined abduction/adduction moments. We conclude that stimulation responses in both dorsiflexion and eversion direction can be set individually and with great accuracy and are reproducible over a prolonged period

    Therapeutic effect of an implantable peroneal nerve stimulator in subjects with chronic stroke and footdrop: A randomized controlled trial

    Get PDF
    Background and Purpose: Footdrop, characterized by a person's inability to raise the foot at the ankle, is a common problem in patients with stroke. A randomized controlled trial was performed to determine the therapeutic effect of using a new implantable, 2-channel peroneal nerve stimulator for 6 months versus an ankle-foot orthosis (AFO). \ud \ud Subjects: Twenty-nine patients with chronic stroke and footdrop participated in the study. The mean time from stroke was 7.3 years (SD=7.3), and all subjects were community ambulators. \ud \ud Methods: The study used a randomized controlled trial design. The functional electrical stimulation (FES) group received the implantable stimulation system for correction of their footdrop. The control group continued using their conventional walking device (ie, AFO, orthopedic shoes, or no walking device). All subjects were measured at baseline and at weeks 4, 8, 12, and 26 in the gait laboratory. The therapeutic effect of FES on the maximum value of the root mean square (RMSmax) of the tibialis anterior (TA) muscle with both flexed and extended knees and walking speed were selected as the primary outcome measures. The RMSmax of the peroneus longus (PL), gastrocnemius (GS), and soleus (SL) muscles with both flexed and extended knees and muscle activity of the TA muscle of the affected leg during the swing phase of gait were selected as secondary outcome measures. \ud \ud Results: A significantly higher RMSmax of the TA muscle with extended knee was found after using FES. No change in walking speed was found when the stimulator was not switched on. A significantly increased RMSmax of the GS muscle with both flexed and extended knees was found after using FES. \ud \ud Discussion and Conclusion: Functionally, no therapeutic effect of implantable peroneal nerve stimulation was found. However, the significantly increased voluntary muscle output of the TA and GS muscles after the use of FES suggests that there was a certain extent of plasticity in the subjects in this study. \u

    Quantifying upper extremity performance with and without assistance of a soft-robotic glove in elderly patients: A kinematic analysis

    Get PDF
    Objective: To explore the direct influence of a soft-robotic glove on movement duration and movement execution in elderly people with decreased hand function during a reach-and-grasp task. Design: Cross-sectional study. Patients: Eight subjects, aged 55+ years, with decreased hand function. Methods: The direct effect of the glove was explored using kinematic analysis during a reach-and-grasp task with a light (100 g) and heavy (1,000/2,500 g) cylindrical object, performed with and without the soft-robotic glove. Results: There was no difference in total movement time between performance with and without the glove. With the glove, the relative time needed to transport the heavy object was shorter, while the relative time needed to grasp the heavy object was longer. In addition, transporting light objects involved a lower peak velocity and larger elbow extension, and grasping the object involved a larger hand opening compared with without glove. Conclusion: As expected, no positive influence of the soft-robotic glove was found on total movement duration in elderly subjects. The influence of the glove on movement execution varied with movement phase. The positive and negative effects found may be due to a perceived confidence while carrying heavy objects with the glove, or compensation for loss of sensation, respectively. This information can be used to improve the glove design