19 research outputs found

    Reading with a Simulated 60-Channel Implant

    Get PDF
    First generation retinal prostheses containing 50–60 electrodes are currently in clinical trials. The purpose of this study was to evaluate the theoretical upper limit (best possible) reading performance attainable with a state-of-the-art 60-channel retinal implant and to find the optimum viewing conditions for the task. Four normal volunteers performed full-page text reading tasks with a low-resolution, 60-pixel viewing window that was stabilized in the central visual field. Two parameters were systematically varied: (1) spatial resolution (image magnification) and (2) the orientation of the rectangular viewing window. Performance was measured in terms of reading accuracy (% of correctly read words) and reading rates (words/min). Maximum reading performances were reached at spatial resolutions between 3.6 and 6 pixels/char. Performance declined outside this range for all subjects. In optimum viewing conditions (4.5 pixels/char), subjects achieved almost perfect reading accuracy and mean reading rates of 26 words/min for the vertical viewing window and of 34 words/min for the horizontal viewing window. These results suggest that, theoretically, some reading abilities can be restored with actual state-of-the-art retinal implant prototypes if “image magnification” is within an “optimum range.” Future retinal implants providing higher pixel resolutions, thus allowing for a wider visual span might allow faster reading rates

    Construct validity and reliability of the Bilateral Vestibulopathy Questionnaire (BVQ)

    Get PDF
    BackgroundThe Bilateral Vestibulopathy Questionnaire (BVQ) is a recently developed 54-item Patient Reported Outcome Measure (PROM) that evaluates the clinically important symptoms of bilateral vestibulopathy (BVP) and its impact on daily life. This study aimed to assess the construct validity and reliability of the BVQ in a large BVP cohort.MethodsPatients diagnosed with BVP were asked to complete a set of questionnaires, including the BVQ, the EuroQol-5D-5L, the Health Utilities Index, the Dizziness Handicap Inventory, the Hospital Anxiety and Depression Scale, and the Oscillopsia Severity Questionnaire. The construct validity of the BVQ was evaluated by confirmatory and exploratory factor analyses (CFA and EFA), followed by hypotheses testing and known groups validity. Structural properties were explored for each individual item. Reliability was assessed by testing the internal consistency of the BVQ constructs (Cronbach's alpha) and test–retest reliability [intraclass correlation coefficients (ICCs)].ResultsA total of 148 patients with BVP (50% women, mean age 66 years) completed the set of questionnaires. The CFA did not show a satisfactory model in the original BVQ. However, the EFA showed a four-factor solution with 20 Likert-scale items related to oscillopsia, imbalance, emotion, and cognition. The succeeding CFA provided evidence for construct validity and an acceptable model of fit. Hypothesis testing confirmed that this shortened version validly measures the constructs to be measured. Statistically significant differences in scores between known groups were found, providing further support for good construct validity. The structural properties were acceptable. Cronbach's alpha confirmed good internal consistency for the four constructs, ranging from 0.80 to 0.89. The ICCs of the 20 Likert-scale items and four visual analog scale (VAS) items were interpreted as good (range 0.76–0.93).ConclusionThis study showed evidence of good construct validity of the new shortened version of the BVQ, consisting of four constructs with a total of 20 Likert-scale items and four VAS items. The final 24-item BVQ proved to be a reliable and valid multi-item PROM that captures the clinically important symptoms of BVP and evaluates its impact on daily life. Consequently, the BVQ enables the gathering of high-level evidence of treatment effectiveness in a systematic and quantitative manner

    Postural impairments in unilateral and bilateral vestibulopathy

    Get PDF
    Chronic imbalance is a major complaint of patients suffering from bilateral vestibulopathy (BV) and is often reported by patients with chronic unilateral vestibulopathy (UV), leading to increased risk of falling. We used the Central SensoriMotor Integration (CSMI) test, which evaluates sensory integration, time delay, and motor activation contributions to standing balance control, to determine whether CSMI measures could distinguish between healthy control (HC), UV, and BV subjects and to characterize vestibular, proprioceptive, and visual contributions expressed as sensory weights. We also hypothesized that sensory weight values would be associated with the results of vestibular assessments (vestibulo ocular reflex tests and Dizziness Handicap Inventory scores). Twenty HCs, 15 UVs and 17 BVs performed three CSMI conditions evoking sway in response to pseudorandom (1) surface tilts with eyes open or, (2) surface tilts with eyes closed, and (3) visual surround tilts. Proprioceptive weights were identified in surface tilt conditions and visual weights were identified in the visual tilt condition. BVs relied significantly more on proprioception. There was no overlap in proprioceptive weights between BV and HC subjects and minimal overlap between UV and BV subjects in the eyes-closed surface-tilt condition. Additionally, visual sensory weights were greater in BVs and were similarly able to distinguish BV from HC and UV subjects. We found no significant correlations between sensory weights and the results of vestibular assessments. Sensory weights from CSMI testing could provide a useful measure for diagnosing and for objectively evaluating the effectiveness of rehabilitation efforts and future treatments designed to restore vestibular function such as hair cell regeneration and vestibular implants

    Bilateral vestibulopathy: a clinical update and proposed diagnostic algorithm

    Get PDF
    Bilateral vestibulopathy (BVP) is characterized by its heterogeneous and chronic nature with various clinical presentations and multiple etiologies. This current narrative review reflects on the main insights and developments regarding clinical presentation. In addition, it proposes a new diagnostic algorithm, and describes available and potential future therapeutic modalities

    Assessing balance in people with bilateral vestibulopathy using the Mini-Balance Evaluation Systems Test (Mini-BESTest): feasibility and comparison with healthy control data

    Get PDF
    OBJECTIVES: Bilateral vestibulopathy (BVP) leads to unsteadiness when walking, which worsens in darkness or on uneven ground, as well as falls. Since simple balance tests struggle to distinguish between BVP and healthy participants, we aimed (1) to test if the Mini-BESTest is feasible in BVP, (2) how people with BVP perform on the Mini-BESTest and (3) to compare these scores with healthy reference data. METHODS: Fifty participants with BVP completed the Mini-BESTest. 12-month falls incidence was obtained by questionnaire. To compare the overall and sub-scores between our participants with BVP and those of healthy participants from the literature (n = 327; obtained via PubMed searches), Mann-Whitney U tests were used. Sub scores within the BVP group were also compared. Spearman correlations were used to investigate the relationships between Mini-BESTest score and age. RESULTS: No floor or ceiling effects were observed. Participants with BVP had significantly lower Mini-BESTest total scores than the healthy group. Anticipatory, reactive postural control and sensory orientation sub scores of the Mini-BESTest were significantly lower in BVP, while dynamic gait sub scores were not significantly different. A stronger negative correlation between age and Mini-BESTest total score was found in BVP than in the healthy group. Scores did not differ between patients with different falls history. CONCLUSION: The Mini-BESTest is feasible in BVP. Our results confirm the commonly reported balance deficits in BVP. The stronger negative association between age and balance in BVP might reflect the age-related decline in the remaining sensory systems with which people with BVP compensate

    The Video Head Impulse Test to Assess the Efficacy of Vestibular Implants in Humans

    No full text
    The purpose of this study was to evaluate whether it is possible to restore the highfrequency angular vestibulo-ocular reflex (aVOR) in patients suffering from a severe bilateral vestibulopathy (BV) and implanted with a vestibular implant prototype. Three patients (S1–3) participated in the study. They received a prototype vestibular implant with one to three electrode branches implanted in the proximity of the ampullary branches of the vestibular nerve. Five electrodes were available for electrical stimulation: one implanted in proximity of the left posterior ampullary nerve in S1, one in the left lateral and another one in the superior ampullary nerves in S2, and one in the right lateral and another one in the superior ampullary nerves in S3. The high-frequency aVOR was assessed using the video head impulse test (EyeSeeCam; EyeSeeTec, Munich, Germany), while motion-modulated electrical stimulation was delivered via one of the implanted vestibular electrodes at a time. aVOR gains were compared to control measurements obtained in the same patients when the device was not activated. In three out of the five tested electrodes the aVOR gain increased monotonically with increased stimulation strength when head impulses were delivered in the plane of the implanted canal. In these cases, gains ranging from 0.4 to values above 1 were measured. A “reversed” aVOR could also be generated when inversed stimulation paradigms were used. In most cases, the gain for excitatory head impulses was superior to that recorded for inhibitory head impulses, consistent with unilateral vestibular stimulation. Improvements of aVOR gain were generally accompanied by a concomitant decrease of corrective saccades, providing additional evidence of an effective aVOR. High inter-electrode and inter-subject variability were observed. These results, together with previous research, demonstrate that it is possible to restore the aVOR in a broad frequency range using motion-modulated electrical stimulation of the vestibular afferents. This provides additional encouraging evidence of the possibility of achieving a useful rehabilitation alternative for patients with BV in the near future
    corecore