454 research outputs found

    A Happiness Approach to Cost-Benefit Analysis

    Get PDF
    Subjective well-being (SWB) surveys ask respondents to quantify their overall or momentary happiness or life-satisfaction, or pose similar questions about other aspects of respondents\u27 mental states. A large empirical literature in economics and psychology has grown up around such surveys. Increasingly, too, scholars have advanced the normative proposal that SWB surveys be used for policymaking—for example, by using survey results to calculate monetary equivalents for nonmarket goods (to be incorporated in cost-benefit analysis), or to calculate gross national happiness. This Article skeptically evaluates the policy role of SWB data. It is critical to distinguish between (1) using SWB surveys as evidence of preference utility versus (2) using them as evidence of experience utility. Preference utility is a measure of the extent to which someone has realized her preferences; experience utility, a measure of the quality of someone\u27s mental states. The two are quite different because individuals can have preferences regarding non-mental occurrences. Having drawn this distinction, the Article then argues, first, that SWB surveys are poor evidence of preference utility—given problems of preference and scale heterogeneity, as well as other difficulties. Stated-preference surveys are a much better survey format for eliciting preference utility. Second, in considering SWB surveys as an experience-utility measure, we should recognize that experientialism about well-being—the view that well-being is simply a matter of good experiences—is highly controversial. More plausibly, an experience-utility measure might be seen as an indicator of one aspect of well-being. However, even constructing this weak experience-utility measure is not straightforward—as the Article demonstrates by discussing Daniel Kahneman\u27s detailed proposal for such a metric

    Microstructure versus Size: Mechanical Properties of Electroplated Single Crystalline Cu Nanopillars

    Get PDF
    We report results of uniaxial compression experiments on single-crystalline Cu nanopillars with nonzero initial dislocation densities produced without focused ion beam (FIB). Remarkably, we find the same power-law size-driven strengthening as FIB-fabricated face-centered cubic micropillars. TEM analysis reveals that initial dislocation density in our FIB-less pillars and those produced by FIB are on the order of 10^(14)  m^(-2) suggesting that mechanical response of nanoscale crystals is a stronger function of initial microstructure than of size regardless of fabrication method

    In situ characterization of vertically oriented carbon nanofibers for three-dimensional nano-electro-mechanical device applications

    Get PDF
    We have performed mechanical and electrical characterization of individual as-grown, vertically oriented carbon nanofibers (CNFs) using in situ techniques, where such high-aspect-ratio, nanoscale structures are of interest for three-dimensional (3D) electronics, in particular 3D nano-electro-mechanical-systems (NEMS). Nanoindentation and uniaxial compression tests conducted in an in situ nanomechanical instrument, SEMentor, suggest that the CNFs undergo severe bending prior to fracture, which always occurs close to the bottom rather than at the substrate–tube interface, suggesting that the CNFs are well adhered to the substrate. This is also consistent with bending tests on individual tubes which indicated that bending angles as large as ~70° could be accommodated elastically. In situ electrical transport measurements revealed that the CNFs grown on refractory metallic nitride buffer layers were conducting via the sidewalls, whereas those synthesized directly on Si were electrically unsuitable for low-voltage dc NEMS applications. Electrostatic actuation was also demonstrated with a nanoprobe in close proximity to a single CNF and suggests that such structures are attractive for nonvolatile memory applications. Since the magnitude of the actuation voltage is intimately dictated by the physical characteristics of the CNFs, such as diameter and length, we also addressed the ability to tune these parameters, to some extent, by adjusting the plasma-enhanced chemical vapor deposition growth parameters with this bottom-up synthesis approach

    Electrochemical modelling of Li-ion battery pack with constant voltage cycling

    Get PDF
    In a battery pack, cell-to-cell chemical variation, or the variation in operating conditions, can possibly lead to current imbalance which can accelerate pack ageing. In this paper, the Pseudo-TwoDimensional(P2D) porous electrode model is extended to a battery pack layout, to predict the overall behaviour and the cell-to-cell variation under constant voltage charging and discharging. The algorithm used in this model offers the flexibility in extending the layout to any number of cells in a pack, which can be of different capacities, chemical characteristics and physical dimensions. The coupled electrothermal effects such as differential cell ageing, temperature variation, porosity change and their effects on the performance of the pack, can be predicted using this modelling algorithm. The pack charging voltage is found to have an impact on the performance as well as the SEI layer growth. Numerical studies are conducted by keeping the cells at different thermal conditions and the results show the necessity to increase the heat transfer coefficient to cool the pack, compared to single cell. The results show that the thermal imbalance has more impact than the change in inter-connecting resistance on the split current distribution, which accelerates the irreversible porous filling and ageing

    A mass transfer based variable porosity model with particle radius change for a Lithium-ion battery

    Get PDF
    Micro pore-clogging in the electrodes due to SEI growth and other side reactions can cause adverse effects on the performance of a Lithium-ion battery. The fundamental problem of volume fraction variation and particle radius change during the charge-discharge process in a lithium-ion battery is modelled in this paper with the help of mass transfer based formulation and demonstrated on a battery with LiCoO2 chemistry. The model can handle the volume fraction change due to intercalation reaction, solvent reduction side reaction and the electrolyte density change due to side reaction contamination in the battery. The entire calculation presented in this paper models particle radius and volume fraction together and therefore gives greater accuracy in calculating the volume-specific-area of the reacting particles which is an important parameter controlling the Butler-Volmer kinetics. The mass deposit on the electrode (or loss of lithium) gives an indication of the amount of pre-lithiation required to maintain cell performance while the amount of mass deposited on the SEI helps to decide the safe operating condition for which the clogging of pores and capacity fade will be minimal. Moreover the model presented in this paper has wide applicability in analysing the stress development inside the battery due to irreversible porous filling

    The cost of solving linear differential equations on a quantum computer: fast-forwarding to explicit resource counts

    Full text link
    How well can quantum computers simulate classical dynamical systems? There is increasing effort in developing quantum algorithms to efficiently simulate dynamics beyond Hamiltonian simulation, but so far exact running costs are not known. In this work, we provide two significant contributions. First, we provide the first non-asymptotic computation of the cost of encoding the solution to linear ordinary differential equations into quantum states -- either the solution at a final time, or an encoding of the whole history within a time interval. Second, we show that the stability properties of a large class of classical dynamics can allow their fast-forwarding, making their quantum simulation much more time-efficient. We give a broad framework to include stability information in the complexity analysis and present examples where this brings several orders of magnitude improvements in the query counts compared to state-of-the-art analysis. From this point of view, quantum Hamiltonian dynamics is a boundary case that does not allow this form of stability-induced fast-forwarding. To illustrate our results, we find that for homogeneous systems with negative log-norm, the query counts lie within the curves 11900Tlog(T)11900 \sqrt{T} \log(T) and 10300Tlog(T)10300 T \log(T) for T[106,1015]T \in [10^6, 10^{15}] and error ϵ=1010\epsilon = 10^{-10}, when outputting a history state.Comment: 8+22 pages, 3 figures. Comments welcome

    Modified electrochemical parameter estimation of NCR18650BD battery using implicit finite volume method

    Get PDF
    The Pseudo Two Dimensional (P2D) porous electrode model is less preferred for real time calculations due to the high computational expense and complexity in obtaining the wide range of electro-chemical parameters despite of its superior accuracy. This paper presents a finite volume based method for re-parametrising the P2D model for any cell chemistry with uncertainty in determining precise electrochemical parameters. The re-parametrisation is achieved by solving a quadratic form of the Butler-Volmer equation and modifying the anode open circuit voltage based on experimental values. Thus the only experimental result, needed to re-parametrise the cell, reduces to the measurement of discharge voltage for any C-rate. The proposed method is validated against the 1C discharge data and an actual drive cycle of a NCR18650BD battery with NCA chemistry when driving in an urban environment with frequent accelerations and regenerative braking events. The error limit of the present model is compared with the electro-chemical prediction of LiyCoO2 battery and found to be superior to the accuracy of the model presented in the literature

    Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy

    Get PDF
    Scanning probe microscopy (SPM) is an important tool for performing measurements at the nanoscale in imaging bacteria or proteins in biology, as well as in the electronics industry. An essential element of SPM is a sharp, stable tip that possesses a small radius of curvature to enhance spatial resolution. Existing techniques for forming such tips are not ideal. High-aspect-ratio, monolithically integrated, as-grown carbon nanofibers (CNFs) have been formed that show promise for SPM applications by overcoming the limitations present in wet chemical and separate substrate etching processes
    corecore