25 research outputs found

    Analysis of the Release Characteristics of Cu-Treated Antimicrobial Implant Surfaces Using Atomic Absorption Spectrometry

    Get PDF
    New developments of antimicrobial implant surfaces doped with copper (Cu) ions may minimize the risk of implant-associated infections. However, experimental evaluation of the Cu release is influenced by various test parameters. The aim of our study was to evaluate the Cu release characteristics in vitro according to the storage fluid and surface roughness. Plasma immersion ion implantation of Cu (Cu-PIII) and pulsed magnetron sputtering process of a titanium copper film (Ti-Cu) were applied to titanium alloy (Ti6Al4V) samples with different surface finishing of the implant material (polished, hydroxyapatite and corundum blasted). The samples were submersed into either double-distilled water, human serum, or cell culture medium. Subsequently, the Cu concentration in the supernatant was measured using atomic absorption spectrometry. The test fluid as well as the surface roughness can alter the Cu release significantly, whereby the highest Cu release was determined for samples with corundum-blasted surfaces stored in cell medium

    A model of implant-associated infection in the tibial metaphysis of rats

    Get PDF
    Objective. Implant-associated infections remain serious complications in orthopaedic and trauma surgery. A main scientific focus has thus been drawn to the development of anti-infective implant coatings. Animal models of implant-associated infections are considered helpful in the in vivo testing of new anti-infective implant coatings. The aim of the present study was to evaluate a novel animal model for generation of implant-associated infections in the tibial metaphysis of rats. Materials and Methods. A custom-made conical implant made of Ti6Al4V was inserted bilaterally at the medial proximal tibia of 26 female Sprague-Dawley rats. Staphylococcus aureus in amounts spanning four orders of magnitude and each suspended in 15 l phosphate buffered saline (PBS) was inoculated into the inner cavity of the implant after the implantation into the defined position. Controls were treated accordingly with PBS alone. Animals were then followed for six weeks until sacrifice. Implant-associated infection was evaluated by microbiological investigation using swabs and determination of viable bacteria in the bone around the implant and the biofilm on the implants after sonification. Results. Irrespective of the initial inoculum, all animals in the various groups harbored viable bacteria in the intraoperative swabs as well as the sonication fluid of the implant and the bone samples. No correlation could be established between initially inoculated CFU and population sizes on implant surfaces at sacrifice. However, a significantly higher viable count was observed from peri-implant bone samples for animals inoculated with 10 6 CFU. Macroscopic signs of animal infection (pus and abscess formation) were only observed for implants inoculated with at least 10 5 CFU S. aureus. Discussion/Conclusion. The results demonstrate the feasibility of this novel animal model to induce an implant-associated infection in the metaphysis of rats, even with comparatively low bacterial inocula. The specific design of the implant allows an application of bacteria in reproducible numbers at well-defined contact sites to the animal bone

    Thrombolysis in stroke patients with elevated inflammatory markers.

    Get PDF
    OBJECTIVE To investigate the prognostic value of white blood cell count (WBC) on functional outcome, mortality and bleeding risk in stroke patients treated with intravenous thrombolysis (IVT). METHODS In this prospective multicenter study from the TRISP registry, we assessed the association between WBC on admission and 3-month poor outcome (modified Rankin Scale 3-6), mortality and occurrence of symptomatic intracranial hemorrhage (sICH; ECASS-II-criteria) in IVT-treated stroke patients. WBC was used as continuous and categorical variable distinguishing leukocytosis (WBC > 10 × 109/l) and leukopenia (WBC  10 mg/l) on outcomes. RESULTS Of 10,813 IVT-treated patients, 2527 had leukocytosis, 112 leukopenia and 8174 normal WBC. Increasing WBC (by 1 × 109/l) predicted poor outcome (ORadjusted 1.04[1.02-1.06]) but not mortality and sICH. Leukocytosis was independently associated with poor outcome (ORadjusted 1.48[1.29-1.69]) and mortality (ORadjusted 1.60[1.35-1.89]) but not with sICH (ORadjusted 1.17[0.94-1.45]). Leukopenia did not predict any outcome. In a subgroup, combined leukocytosis and elevated CRP had the strongest association with poor outcome (ORadjusted 2.26[1.76-2.91]) and mortality (ORadjusted 2.43[1.86-3.16]) when compared to combined normal WBC and CRP. CONCLUSION In IVT-treated patients, leukocytosis independently predicted poor functional outcome and death. Bleeding complications after IVT were not independently associated with leukocytosis

    Experimental Investigation of Material Transfer on Bearings for Total Hip Arthroplasty—A Retrieval Study on Ceramic and Metallic Femoral Heads

    No full text
    Metallic deposition is a commonly observed phenomenon on the surface of revised femoral heads in total hip arthroplasty and can lead to increased wear due to third bodies. In order to find out the origin and composition of the transfer material, 98 retrieved femoral heads of different materials were examined with regard to the cause of revision, localization, pattern and composition of the transfer material by energy dispersive X-ray spectroscopy. We found that in 53.1%, the deposition was mostly in the region of the equator and the adjacent pole of the femoral heads. The most common cause for revision of heads with metallic deposition was polyethylene wear (43.9%). Random stripes (44.9%), random patches (41.8%) and solid patches (35.7%) were most prevalent on retrieved femoral heads. Random patches were a typical pattern in ceramic-on-ceramic bearing couples. The solid patch frequently occurred in association with dislocation of the femoral head (55%). The elemental analysis of the depositions showed a variety of different materials. In most cases, titanium was an element of the transferred material (76.5%). In addition to metallic components, several non-metallic components were also detected, such as carbon (49%) or sulfur (4.1%). Many of the determined elements could be assigned with regard to their origin with the help of the associated revision cause. Since the depositions lead to an introduction of third-body particles and thus to increased wear, the depositions on the bearing surfaces should be avoided in any case