    Variability in Blood Pressure Assessment in Patients Supported with the HeartMate 3TM

    Get PDF
    Targeted blood pressure (BP) control is a goal of left ventricular assist device medical management, but the interpretation of values obtained from noninvasive instruments is challenging. In the MOMENTUM 3 Continued Access Protocol, paired BP values in HeartMate 3 (HM3) patients were compared from arterial (A)-line and Doppler opening pressure (DOP) (319 readings in 261 patients) and A-line and automated cuff (281 readings in 247 patients). Pearson (R) correlations between A-line mean arterial (MAP) and systolic blood pressures (SBP) were compared with DOP and cuff measures according to the presence (\u3e1 pulse in 5 seconds) or absence of a palpable radial pulse. There were only moderate correlations between A-line and noninvasive measurements of SBP (DOP R = 0.58; cuff R = 0.47) and MAP (DOP R = 0.48; cuff R = 0.37). DOP accuracy for MAP estimation, defined as the % of readings within ± 10 mmHg of A-line MAP, decreased from 80% to 33% for DOP ≤ 90 vs. \u3e90 mmHg, and precision also diminished (mean absolute difference [MAD] increased from 6.3 ± 5.6 to 16.1 ± 11.4 mmHg). Across pulse pressures, cuff MAPs were within ±10 mmHg of A-line 62.9%-68.8% of measures and MADs were negligible. The presence of a palpable pulse reduced the accuracy and precision of the DOP-MAP estimation but did not impact cuff-MAP accuracy or precision. In summary, DOP may overestimate MAP in some patients on HM3 support. Simultaneous use of DOP and automated cuff and radial pulse may be needed to guide antihypertensive medication titration in outpatients on HM3 support

    PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: The PREVENT multi-center study

    Get PDF
    BACKGROUND: Recommended structured clinical practices including implant technique, anti-coagulation strategy, and pump speed management (PREVENT [PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management] recommendations) were developed to address risk of early (<3 months) pump thrombosis (PT) risk with HeartMate II (HMII; St. Jude Medical, Inc. [Thoratec Corporation], Pleasanton, CA). We prospectively assessed the HMII PT rate in the current era when participating centers adhered to the PREVENT recommendations. METHODS: PREVENT was a prospective, multi-center, single-arm, non-randomized study of 300 patients implanted with HMII at 24 participating sites. Confirmed PT (any suspected PT confirmed visually and/or adjudicated by an independent assessor) was evaluated at 3 months (primary end-point) and at 6 months after implantation. RESULTS: The population included 83% men (age 57 years ± 13), 78% destination therapy, and 83% Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Profile 1-3. Primary end-point analysis showed a confirmed PT of 2.9% at 3 months and 4.8% at 6 months. Adherence to key recommendations included 78% to surgical recommendations, 95% to heparin bridging, and 79% to pump speeds ≥9,000 RPMs (92% >8,600 RPMs). Full adherence to implant techniques, heparin bridging, and pump speeds ≥9,000 RPMs resulted in a significantly lower risk of PT (1.9% vs 8.9%; p < 0.01) and lower composite risk of suspected thrombosis, hemolysis, and ischemic stroke (5.7% vs 17.7%; p < 0.01) at 6 months. CONCLUSIONS: Adoption of all components of a structured surgical implant technique and clinical management strategy (PREVENT recommendations) is associated with low rates of confirmed PT

    Left ventricular assist device effects on metabolic substrates in the failing heart.

    Get PDF
    Heart failure patients have inadequate nutritional intake and alterations in metabolism contributing to an overall energy depleted state. Left ventricular assist device (LVAD) support is a common and successful intervention in patients with end-stage heart failure. LVAD support leads to alterations in cardiac output, functional status, neurohormonal activity and transcriptional profiles but the effects of LVADs on myocardial metabolism are unknown. This study set out to measure cardiac metabolites in non-failing hearts, failing hearts, and hearts post-LVAD support.The study population consisted of 8 non-ischemic failing (at LVAD implant) and 8 post-LVAD hearts, plus 8 non-failing hearts obtained from the tissue bank at the University of Colorado. NMR spectroscopy was utilized to evaluate differences in myocardial energy substrates. Paired and non-paired t-tests were used to determine differences between the appropriate groups.Glucose and lactate values both decreased from non-failing to failing hearts and increased again significantly in the (paired) post-LVAD hearts. Glutamine, alanine, and aromatic amino acids decreased from non-failing to failing hearts and did not change significantly post-LVAD. Total creatine and succinate decreased from non-failing to failing hearts and did not change significantly post-LVAD.Measured metabolites related to glucose metabolism are diminished in failing hearts, but recovered their values post-LVAD. This differed from the amino acid levels, which decreased in heart failure but did not recover following LVAD. Creatine and the citric acid cycle intermediate succinate followed a similar pattern as the amino acid levels

    Influence of donor cocaine use on outcome after cardiac transplantation: analysis of the United Network for Organ Sharing Thoracic Registry

    No full text
    Heart transplantation from donors with a history of cocaine abuse remains controversial. Therefore, we examined the consequence of donor cocaine-use history on all-cause mortality and the development of coronary artery disease after heart transplantation. Using the United Network for Organ Sharing Thoracic Registry we identified 9,217 first-time heart-only adult transplant recipients between January 1999 and December 2003, and then divided this cohort into sub-groups based on the reported history of donor cocaine use. Multivariate analysis revealed no difference in mortality or development of coronary artery disease at 1 and 5 years between transplant recipients who received an organ from donors with a history of cocaine use when compared with donors having no history of cocaine use

    Clinical and Hemodynamic Variables for Failing Hearts.

    No full text
    <p>LVEDs: Left Ventricular End Systolic Diameter, LVEDd: Left Ventricular End Diastolic Diameter, PAP: Pulmonary Artery Pressure, MAP: Mean Arterial Pressure, NYHA: New York Heart Association.</p

    Metabolite Differences Between Patient Groups (µmol/g of tissue).

    No full text
    <p>Metabolite differences between non-failing and failing hearts (* = p<0.05) and failing and post-VAD hearts (** = p<0.05).</p