    A Filmless Radiology Department in a Full Digital Regional Hospital: Quantitative Evaluation of the Increased Quality and Efficiency

    Get PDF
    Reggio Emilia hospital installed Picture Archiving and Communications Systems (PACS) as the final step towards a completely digital clinical environment completing the HIS/EMR and 1,400 web/terminals for patient information access. Financial benefits throughout the hospital were assessed upfront and measured periodically. Key indicators (radiology exam turnaround time, number of radiology procedures performed, inpatients length of stay before and after the PACS implementation, etc.) were analyzed and values were statistically tested to assess workflow and productivity improvements. The hospital went “filmless” in 28 weeks. Between the half of 2004 and the respective period in 2003, overall Radiology Department productivity increased by 12%, TAT improved by more than 60%. Timelier patient care resulted in decreased lengths of stay. Neurology alone experienced a 12% improvement in average patient stay. To quantify the impact of PACS on the average hospital stays and the expected productivity benefits to inpatient productivity were used a “high level” and a “detailed” business model. Annual financial upsides have exceeded $1.9 millions/year. A well-planned PACS deployment simplifies imaging workflow and improves patient care throughout the hospital while delivering substantial financial benefits. Staff buy-in was the key in this process and on-going training and process monitoring are a must

    Burnout among surgeons before and during the SARS-CoV-2 pandemic: an international survey

    Get PDF
    Background: SARS-CoV-2 pandemic has had many significant impacts within the surgical realm, and surgeons have been obligated to reconsider almost every aspect of daily clinical practice. Methods: This is a cross-sectional study reported in compliance with the CHERRIES guidelines and conducted through an online platform from June 14th to July 15th, 2020. The primary outcome was the burden of burnout during the pandemic indicated by the validated Shirom-Melamed Burnout Measure. Results: Nine hundred fifty-four surgeons completed the survey. The median length of practice was 10 years; 78.2% included were male with a median age of 37 years old, 39.5% were consultants, 68.9% were general surgeons, and 55.7% were affiliated with an academic institution. Overall, there was a significant increase in the mean burnout score during the pandemic; longer years of practice and older age were significantly associated with less burnout. There were significant reductions in the median number of outpatient visits, operated cases, on-call hours, emergency visits, and research work, so, 48.2% of respondents felt that the training resources were insufficient. The majority (81.3%) of respondents reported that their hospitals were included in the management of COVID-19, 66.5% felt their roles had been minimized; 41% were asked to assist in non-surgical medical practices, and 37.6% of respondents were included in COVID-19 management. Conclusions: There was a significant burnout among trainees. Almost all aspects of clinical and research activities were affected with a significant reduction in the volume of research, outpatient clinic visits, surgical procedures, on-call hours, and emergency cases hindering the training. Trial registration: The study was registered on clicaltrials.gov "NCT04433286" on 16/06/2020

    Unexpected Liver Embryonal Sarcoma in the Adult: Diagnosis and Treatment

    No full text
    Undifferentiated embryonal sarcoma of the liver is a malignancy with poor prognosis observed more frequently in children between 6 and 10 years old and very rarely found in adults. We present a case of embryonal sarcoma of the liver in a 60-year-old woman without significant medical history who presented to our attention with constitutional symptoms. Preoperative assessments did not show alterations in blood chemistry or tumor markers. Imaging studies showed a huge mass lying in the right abdominal quadrants, strictly adherent to the liver. The tumor was partially cystic with a thickened wall, sporadic contrast enhancement, and solid component. The patient underwent excision of the mass with associated liver bisegmentectomy S5-S6. Postoperative course was uneventful. The definitive histological diagnosis revealed the presence of embryonal sarcoma of the liver. We describe the clinical, histopathological, and therapeutic options adopted in the multimodal treatment of this disease

    Application of QC_DR Software for Acceptance Testing and Routine Quality Control of Direct Digital Radiography Systems: Initial Experiences using the Italian Association of Physicist in Medicine Quality Control Protocol

    No full text
    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance

    Comparison of different commercial FFDM units by means of physical characterization and contrast-detail analysis

    No full text
    The purpose of this study was to perform a complete evaluation of three pieces of clinical digital mammography equipment. Image quality was assessed by performing physical characterization and contrast-detail (CD)analysis. We considered three different FFDM systems: a computed radiography unit Fuji \u201cFCR 5000 MA\u201d and two flat-panel units, the indirect conversion a-Si based GE \u201cSenographe 2000D\u201d and the direct conversion a-Se based IMS \u201cGiotto Image MD.\u201d The physical characterization was estimated by measuring the MTF, NNPS, and DQE of the detectors with no antiscatter grid and over the clinical range of exposures. The CD analysis was performed using a CDMAM 3.4 phantom and custom software designed for automatic computation of the contrast detail curves. The physical characterization of the three digital systems confirms the excellent MTF properties of the direct conversion flat-panel detector (FPD). We performed a relative standard deviation (RSD) snalysis, for investigating the different components of the noise presented by the three systems. It turned out that the two FPDs show a significant additive component, whereas for the CR system the statistical noise is dominant. The multiplicative factor is a minor constituent for all the systems. The two FPDs demonstrate better DQE, with respect to the CR system, for exposures higher than 70 uGy. The CD analysis indicated that the three systems are not statistically different for detail objects with a diameter greater than 0.3 mm. However, the IMS system showed a statistically significant different response for details smaller than 0.3 mm. In this case, the poor response of the a-Se detector could be attributed to its high-frequency noise characteristics, since its MTF, NEQ, and DQE are not inferior to those of the other systems. The CD results were independent of exposure level, within the investigated clinical range. We observed slight variations in the CD results, due to the changes in the visualization parameters (window/level and magnification factor). This suggests that radiologists would benefit from viewing images using varied window/ level and magnification

    A comparison of digital radiography systems in terms of effective detective quantum efficiency

    No full text
    Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report # 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E0, which is the exposure at which a system is normally operated, 1/3 E0, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures