7 research outputs found

    Endodontic re-treatment and restorative treatment of a dens invaginatus type II through new technologies

    Get PDF
    Background: The complex anatomy of dens invaginatus makes access cavity to root canal system difficult, which has an impact on the prognosis of these teeth. A novel technique, based on new technologies, is proposed to make access cavity conservative and guided with minimal dental structure lost. Material and Methods: This case report shows the root canal retreatment and the endodontic surgery of a dens invaginatus type II in a left lateral upper incisor previously treated which was affected by a chronic apical abscess and an apical fracture. A Cone Beam Computed Tomography was performed to better diagnosis the dental anatomy. An intraoral scan was performed to get a digital 3D model. A computer-guided implant planning software was used to plan the access cavity and design the splint guided. Finally, the clinical crown was restored by a resin nanoceramic veneer made by a chairside system made up of an intraoral scanning unit and a grinding unit. Last, the authors carried through the endodontic surgery to extract the apical fractured fragment. Results: Follow-up appointments at 6, 12 and 18 months showed a radiographic reduction of the periapical lesion and absence of clinical signs. Conclusions: The splint guide allowed a guided and conservative access cavity to root canal system. It facilitates the root canal retreatment and improves the prognosis of the teeth with dental malformations

    Association Between Preexisting Versus Newly Identified Atrial Fibrillation and Outcomes of Patients With Acute Pulmonary Embolism

    Get PDF
    Background Atrial fibrillation (AF) may exist before or occur early in the course of pulmonary embolism (PE). We determined the PE outcomes based on the presence and timing of AF. Methods and Results Using the data from a multicenter PE registry, we identified 3 groups: (1) those with preexisting AF, (2) patients with new AF within 2 days from acute PE (incident AF), and (3) patients without AF. We assessed the 90-day and 1-year risk of mortality and stroke in patients with AF, compared with those without AF (reference group). Among 16 497 patients with PE, 792 had preexisting AF. These patients had increased odds of 90-day all-cause (odds ratio [OR], 2.81; 95% CI, 2.33-3.38) and PE-related mortality (OR, 2.38; 95% CI, 1.37-4.14) and increased 1-year hazard for ischemic stroke (hazard ratio, 5.48; 95% CI, 3.10-9.69) compared with those without AF. After multivariable adjustment, preexisting AF was associated with significantly increased odds of all-cause mortality (OR, 1.91; 95% CI, 1.57-2.32) but not PE-related mortality (OR, 1.50; 95% CI, 0.85-2.66). Among 16 497 patients with PE, 445 developed new incident AF within 2 days of acute PE. Incident AF was associated with increased odds of 90-day all-cause (OR, 2.28; 95% CI, 1.75-2.97) and PE-related (OR, 3.64; 95% CI, 2.01-6.59) mortality but not stroke. Findings were similar in multivariable analyses. Conclusions In patients with acute symptomatic PE, both preexisting AF and incident AF predict adverse clinical outcomes. The type of adverse outcomes may differ depending on the timing of AF onset.info:eu-repo/semantics/publishedVersio

    Novel Technique of Interproximal Enamel Reduction Based on Computer-Aided Navigation Technique—An In Vitro Study

    No full text
    The aim of this study was to analyze and compare the accuracy of a novel interproximal enamel reduction (IPR) technique based on a computer-aided static navigation technique with respect to a conventional free-hand-based technique for interproximal enamel reduction. Twenty anatomical-based experimental cast models of polyurethane were randomly distributed into the following IPR techniques: IPR technique based on computer-aided static navigation technique (n = 10) (GI) for Group A and conventional free-hand-based technique for the IPR (n = 10) (FHT) for Group B. The anatomical-based experimental cast models of polyurethane randomly assigned to the GI study group were submitted for a preoperative 3D intraoral surface scan; then, datasets were uploaded into 3D implant-planning software to design virtual templates for the interproximal enamel reduction technique. Afterward, the anatomical-based experimental cast models of polyurethane of both GI and FHT study groups were subjected to a postoperative digital impression by a 3D intraoral surface scan to compare the accuracy of the interproximal enamel reduction techniques at the buccal (mm), lingual/palatal (mm), and angular (◩) levels using the Student t-test. Statistically significant differences between the interproximal enamel reduction technique based on the computer-aided static navigation technique and the conventional free-hand-based technique for the interproximal enamel reduction at the buccal (p = 0.0008) and lingual/palatal (p p = 0.1042). The interproximal enamel reduction technique based on computer-aided static navigation technique was more accurate than the conventional free-hand-based technique for interproximal enamel reduction

    Relationship between Prostate Inflammation and Periodontal Disease—A Systematic Review and Meta-Analysis

    No full text
    The aim of this systematic review and meta-analysis was to analyze the association between periodontal disease and prostate inflammation with a null hypothesis stating that periodontal disease does not increase the incidence of prostate inflammation. Materials and methods: A systematic literature review and meta-analysis of longitudinal observational cohort and case-control studies that evaluated the odds ratio or hazard ratio and confidence interval was undertaken based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations (2020). A total of four databases were consulted in the literature search: PubMed-Medline, Scopus, Embase, and Web of Science. After eliminating duplicated articles and applying the inclusion criteria, seven articles were selected for the qualitative and quantitative analyses. Results: Four observational cohort studies and three observational cohort case-control studies were included in the meta-analysis. The four observational cohort studies were combined using the random effects model to estimate a hazard ratio of 1.32 with a confidence interval of 95% between 0.87 and 1.77. The meta-analysis presented high heterogeneity (Q test = 56.1; p value 2 = 94.9%). Moreover, the three observational case-control studies were combined using the random effects model to estimate an odds ratio of 1.62 with a confidence interval of 95% between 1.41 and 1.84. The meta-analysis presented high heterogeneity (Q test = 1.07; p value = 0.782; I2 = 0%). Conclusions: The incidence of periodontal disease does not increase the risk of the incidence of prostate inflammation

    Digital technique to analyze the wear of screw-retained implant supported metal-ceramic dental prostheses and natural tooth as antagonist: a pilot study

    No full text
    Abstract The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist. Materials and methods Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up. Afterwards, an alignment procedure of the digital files (STL1-STL3) was performed on a reverse engineering morphometric software (3D Geomagic Capture Wrap) and volume changes at the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were analyzed using Student’s t-test. Moreover, Gage R&R statistical analysis was conducted to analyze the repeatability and reproducibility of the digital technique. Results Gage R&R showed a variability attributable to the digital technique of 3.8% (among the measures of each operator) and 4.5% (among operators) of the total variability; resulting repeatable and reproducible, since the variabilities were under 10%. In addition, statistically significant differences were shown at the wear volume (ÎŒm3) of both the natural tooth as antagonist (p < 0.0001) and the screw-retained implant-supported metal-ceramic dental prostheses between 3- and 6-months follow-up (p = 0.0002). Conclusion The novel digital measurement technique results repeatable and reproducible to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist

    Influence of parallel pins on the angle deviation for placement of dental implants: an in vitro study

    No full text
    Abstract The aim of the present study was to analyze and compare the angle deviation of two, four and six adjacent dental implants placed with and without straight parallel pins. Materials and Methods: Two hundred and forty (240) dental implants were selected and randomly allocated into the following study groups: Two dental implants placed with straight parallel pins (Ref.: 144-100, BioHorizons, Birmingham, AL, USA) (n = 10) (2PP); Two dental implants placed without parallel pins (n = 10) (2withoutPP); Four dental implants placed with straight parallel pins hT(n = 10) (4PP); Four dental implants placed without parallel pins (n = 10) (4withoutPP); Six dental implants placed with straight parallel pins (n = 10) (6PP) and Six dental implants placed without parallel pins (n = 10) (6withoutPP). The dental implants randomly assigned to groups 2PP and 2withoutPP were placed into standardized polyurethane models of partially edentulous upper jaws in tooth positions 2.4 and 2.6, the dental implants randomly assigned to groups 4PP and 4withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 2.4 and 2.6, and the dental implants randomly assigned to groups 6PP and 6withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 1.2, 2.2, 2.4 and 2.6. Afterwards, postoperative CBCT scans and digital impressions were aligned in a 3D implant-planning software to compare the angle deviation (°) of two, four and six adjacent dental implants placed with and without straight parallel pins using the General Linear Model statistical analysis. Results: Statistically significant differences were found between the angle deviation of 2 dental implants placed with straight parallel pins (p < 0.0001) and between the angle deviation of 4 dental implants placed with straight parallel pins (p = 0.0024); however, no statistically significant differences were found in the angle deviation of 6 dental implants placed with straight parallel pins (p = 0.9967). Conclusion: The use of a straight parallelization pin results in lower angle deviation between two and four adjacent dental implants; however, it is not effective for a larger number of dental implants

    Comparative analysis of two navigation techniques based on augmented reality technology for the orthodontic mini-implants placement

    Get PDF
    Abstract To analyze and compare the accuracy and root contact prevalence, comparing a conventional freehand technique and two navigation techniques based on augmented reality technology for the orthodontic self-drilling mini-implants placement. Methods Two hundred and seven orthodontic self-drilling mini-implants were placed using either a conventional freehand technique (FHT) and two navigation techniques based on augmented reality technology (AR TOOTH and AR SCREWS). Accuracy across different dental sectors was also analyzed. CBCT and intraoral scans were taken both prior to and following orthodontic self-drilling mini-implants placement. The deviation angle and horizontal were then analyzed; these measurements were taken at the coronal entry point and apical endpoint between the planned and performed orthodontic self-drilling mini-implants. In addition, any complications resulting from mini-implant placement, such as spot perforations, were also analyzed across all dental sectors. Results The statistical analysis showed significant differences between study groups with regard to the coronal entry-point (p < 0.001), apical end-point(p < 0.001) and angular deviations (p < 0.001). Furthermore, statistically significant differences were shown between the orthodontic self-drilling mini-implants placement site at the coronal entry-point (p < 0.0001) and apical end-point (p < 0.001). Additionally, eight root perforations were observed in the FHT group, while there were no root perforations in the two navigation techniques based on augmented reality technology. Conclusions The navigation techniques based on augmented reality technology has an effect on the accuracy of orthodontic self-drilling mini-implants placement and results in fewer intraoperative complications, comparing to the conventional free-hand technique. The AR TOOTH augmented reality technique showed more accurate results between planned and placed orthodontic self-drilling mini-implants, comparing to the AR SCREWS and conventional free-hand techniques. The navigation techniques based on augmented reality technology showed fewer intraoperative complications, comparing to the conventional free-hand technique
    corecore