32 research outputs found

    Fetal electrocardiogram: ST waveform analysis in intrapartum surveillance

    Get PDF
    ST waveform analysis of fetal electrocardiogram (ECG) for intrapartum surveillance (STAN) is a newly introduced method for fetal surveillance. The purpose of this commentary is to assist in the proper use of fetal ECG in combination with cardiotocography (CTG) during labour. Guidelines and recommendations concerning CTG and ST waveform interpretation and classification are stated that were agreed on by the European experts on ST waveform analysis for intrapartum surveillance during a meeting in Utretcht, the Netherlands in January 2007

    Comparing the effect of STan (cardiotocographic electronic fetal monitoring (CTG) plus analysis of the ST segment of the fetal electrocardiogram) with CTG alone on emergency caesarean section rates: study protocol for the STan Australian Randomised controlled Trial (START).

    Get PDF
    BACKGROUND: Cardiotocography is almost ubiquitous in its use in intrapartum care. Although it has been demonstrated that there is some benefit from continuous intrapartum fetal monitoring using cardiotocography, there is also an increased risk of caesarean section which is accompanied by short-term and long-term risks to the mother and child. There is considerable potential to reduce unnecessary operative delivery with up to a 60% false positive diagnosis of fetal distress using cardiotocography alone. ST analysis of the fetal electrocardiogram is a promising adjunct to cardiotocography alone, and permits detection of metabolic acidosis of the fetus, potentially reducing false positive diagnosis of fetal distress. METHODS: This study will be a single-centre, parallel-group, randomised controlled trial, conducted over 3 years. The primary hypothesis will be that the proportion of women with an emergency caesarean section on ST analysis will not equal that for women on cardiotocography monitoring alone. Participants will be recruited at the Women's and Children's Hospital, a high-risk specialty facility with approximately 5000 deliveries per annum. A total of 1818 women will be randomised to the treatment or conventional arm with an allocation ratio of 1:1, stratified by parity. The primary outcome is emergency caesarean section (yes/no). Statistical analysis will follow standard methods for randomised trials and will be performed on an intention-to-treat basis. Secondary maternal and neonatal outcomes will also be analysed. Additional study outcomes include psychosocial outcomes, patient preferences and cost-effectiveness. DISCUSSION: Approximately 20% of Australian babies are delivered by emergency caesarean section. This will be the first Australian trial to examine ST analysis of the fetal electrocardiogram as an adjunct to cardiotocography as a potential method for reducing this proportion. The trial will be among the first to comprehensively examine ST analysis, taking into account the impact on psychosocial well-being as well as cost-effectiveness. This research will provide Australian evidence for clinical practice and guideline development as well as for policy-makers and consumers to make informed, evidence-based choices about care in labour. TRIAL REGISTRATION: ANZCTR, ACTRN1261800006268 . Registered on 19 January 2018

    A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have shown that a combination of CTG and ST-analysis of the fetal electrocardiogram (ECG) reduces the rates of metabolic acidosis and instrumental delivery. However, in both trials FBS was still performed in the ST-analysis arm, and it is therefore still unknown if the observed results were indeed due to the ST-analysis or to the use of FBS in combination with ST-analysis.</p> <p>Methods/Design</p> <p>We aim to evaluate the effectiveness of non-invasive monitoring (CTG + ST-analysis) as compared to normal care (CTG + FBS), in a multicentre randomised clinical trial setting. Secondary aims are: 1) to judge whether ST-analysis of fetal electrocardiogram can significantly decrease frequency of performance of FBS or even replace it; 2) perform a cost analysis to establish the economic impact of the two treatment options.</p> <p>Women in labour with a gestational age ≥ 36 weeks and an indication for CTG-monitoring can be included in the trial.</p> <p>Eligible women will be randomised for fetal surveillance with CTG and, if necessary, FBS or CTG combined with ST-analysis of the fetal ECG.</p> <p>The primary outcome of the study is the incidence of serious metabolic acidosis (defined as pH < 7.05 and Bd<sub>ecf </sub>> 12 mmol/L in the umbilical cord artery). Secondary outcome measures are: instrumental delivery, neonatal outcome (Apgar score, admission to a neonatal ward), incidence of performance of FBS in both arms and cost-effectiveness of both monitoring strategies across hospitals.</p> <p>The analysis will follow the intention to treat principle. The incidence of metabolic acidosis will be compared across both groups. Assuming a reduction of metabolic acidosis from 3.5% to 2.1 %, using a two-sided test with an alpha of 0.05 and a power of 0.80, in favour of CTG plus ST-analysis, about 5100 women have to be randomised. Furthermore, the cost-effectiveness of CTG and ST-analysis as compared to CTG and FBS will be studied.</p> <p>Discussion</p> <p>This study will provide data about the use of intrapartum ST-analysis with a strict protocol for performance of FBS to limit its incidence. We aim to clarify to what extent intrapartum ST-analysis can be used without the performance of FBS and in which cases FBS is still needed.</p> <p>Trial Registration Number</p> <p>ISRCTN95732366</p

    Standardized outcome measures for pregnancy and childbirth, an ICHOM proposal

    Get PDF
    Background: Value-based health care aims to optimize the balance of patient outcomes and health care costs. To improve value in perinatal care using this strategy, standard outcomes must first be defined. The objective of this work was to define a minimum, internationally appropriate set of outcome measures for evaluating and improving perinatal care with a focus on outcomes that matter to women and their families. Methods: An interdisciplinary and international Working Group was assembled. Existing literature and current measurement initiatives were reviewed. Serial guided discussions and validation surveys provided consumer input. A series of nine teleconferences, incorporating a modified Delphi process, were held to reach consensus on the proposed Standard Set. Results: The Working Group selected 24 outcome measures to evaluate care during pregnancy and up to 6 months postpartum. These include clinical outcomes such as maternal and neonatal mortality and morbidity, stillbirth, preterm birth, birth injury and patient-reported outcome measures (PROMs) that assess health-related quality of life (HRQoL), mental health, mother-infant bonding, confidence and success with breastfeeding, incontinence, and satisfaction with care and birth experience. To support analysis of these outcome measures, pertinent baseline characteristics and risk factor metrics were also defined. Conclusions: We propose a set of outcome measures for evaluating the care that women and infants receive during pregnancy and the postpartum period. While validation and refinement via pilot implementation projects are needed, we view this as an important initial step towards value-based improvements in care

    Complicated, complex, and compliant: best practice in obstetrics

    No full text
    In this study, the distinction between complicated and complex is used to shed some light on compliance with best practice guidelines. Data were gathered related to obstetric practice in labor wards and operating theaters at two Scandinavian hospitals, one of them being a university hospital, and in a training facility. The complexity of obstetrical intervention is analyzed in this paper, as is the potential of compliance-based routines in obstetrics. Complex situations are different from complicated ones and patient safety management efforts should recognize and enhance the sort of diversity that helps the emergence of resilience in complex situations. © 2012 Springer-Verlag London Limited

    Complicated, complex, and compliant: best practice in obstetrics

    No full text
    In this study, the distinction between complicated and complex is used to shed some light on compliance with best practice guidelines. Data were gathered related to obstetric practice in labor wards and operating theaters at two Scandinavian hospitals, one of them being a university hospital, and in a training facility. The complexity of obstetrical intervention is analyzed in this paper, as is the potential of compliance-based routines in obstetrics. Complex situations are different from complicated ones and patient safety management efforts should recognize and enhance the sort of diversity that helps the emergence of resilience in complex situations. © 2012 Springer-Verlag London Limited

    Prediction of neonatal metabolic acidosis in women with a singleton term pregnancy in cephalic presentation: an external validation study

    No full text
    Objective: To externally validate two previously developed prognostic models that predict the risk for developing metabolic acidosis in newborns using both antepartum (model 1) and intrapartum (combined with antepartum, model 2) risk factors: parity, previous cesarean section, maternal diabetes mellitus, gestational age, induced onset of labor, meconium-stained amniotic fluid, and use of ST analysis. Study Design: The two prediction models were applied in women in active labor at more than 36 gestational weeks with singleton fetuses in cephalic presentation and with high-risk pregnancies (n = 5049) who were included in a Swedish randomized trial between December 1, 1998, and June 4, 2000. The prognostic ability of the models was determined using calibration and discrimination measures. Results: Of 5049 infants in the validation population, 54 (1.1%) suffered from metabolic acidosis. After adjustment for incidence differences between the Dutch and Swedish cohorts, the prognostic models showed good calibration and moderate overall discrimination (C statistic 0.63, 95% confidence interval [CI] 0.55 to 0.71; and 0.64, 95% CI 0.55 to 0.72), for models 1 and 2, respectively). Conclusion: External validation of the clinical prediction models for metabolic acidosis in Swedish infants showed good calibration and moderate discriminative ability. Updating of the models to enhance their predictive abilities seems indicated.Ewoud Schuit, Isis Amer-Wahlin, Rolf H.H. Groenwold, Ben W.J. Mol, Karel G.M. Moons, Anneke Kwe

    The electrical heart axis and ST events in fetal monitoring: a post-hoc analysis following a multicentre randomised controlled trial

    Get PDF
    OBJECTIVE: Reducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. However, its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events. METHODS: A post-hoc analysis was performed following a multicentre randomised controlled trial, including 1097 patients from two participating centres. All women were monitored with ST analysis during labour. Cases of fetal metabolic acidosis, poor signal quality, missing blood gas analysis, and congenital heart disease were excluded. The orientation of the fetal electrical heart axis affects the height of the initial T/QRS baseline, and therefore the incidence of ST events. We grouped tracings with the same initial baseline T/QRS value. We depicted the number of ST events as a function of the initial baseline T/QRS value with a linear regression model. RESULTS: A significant increment of ST events was observed with increasing height of the initial T/QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p<0.001. The most frequent T/QRS baseline is 0.12. CONCLUSION: The orientation of the fetal electrical heart axis and accordingly the height of the initial T/QRS baseline should be taken into account in fetal monitoring with ST analysis
    corecore