2 research outputs found

    Surgical and functional outcome after resection of 64 petroclival meningiomas

    Get PDF
    Objective: The management of petroclival meningiomas (PCMs) remains notoriously difficult due to their close association with neurovascular structures and their complex anatomy, hence the surgical paradigm change from radical to functional resection in the past. With this study, we aimed to analyze surgical and functional outcomes of a modern consecutive series of patients with PCMs. Methods: We reviewed patient charts and imaging data of 64 consecutive patients from 2006 to 2018 with a PCM resected at our institution and compared surgical and functional outcomes between subgroups stratified by surgical approach. Results: Females comprised 67.2% of patients (n = 43), with a mean age of 55 years (median 56; range 21–84). Follow-up data were available for 68.8% and reached a mean of 42.3 months (range 1–129) with a median of 28.5 months. The mean tumor diameter was 37.3 mm (standard deviation (SD) 15.4; median 37.0). Infiltration of the cavernous sinus was observed in 34 cases (53.1%), and the lesions affected the brain stem in 28 cases (43.8%). Preoperative cranial nerve palsy was observed in 73.4% of cases; trigeminal neuropathy (42.2%), hearing loss (32.8%), and impairment of vision (18.8%) were the most common. A retrosigmoid approach was employed in 47 cases (78.1%), pterional in 10 (15.6%), combined petrosal in 2 (3.1%), and transnasal and subtemporal in 1 (1.6%). Fifteen cases (23.4%) were resected in a two-staged fashion. Gross total resection (GTR) was attempted in 30 (46.9%) cases without cavernous sinus infiltration and was achieved in 21 (70.0%) of these cases. Surgical complications occurred in 13 cases (20.3%), most commonly meningitis (n = 4; 6.3%). Postoperatively, 56 patients (87.5%) developed new cranial nerve palsy, of which 36 (63.6%) had improved or resolved on last follow up. Achieving GTR was not significantly associated with higher rates of surgical complications (chi-square; p = 0.288) or postoperative cranial nerve palsy (chi-square; p = 0.842). Of all cases, 20 (31.3%) underwent postoperative radiation. Tumor progression was observed in 10 patients (15.9%) after a mean 102 months (median 124). Conclusions: Surgical resection remains the mainstay of treatment for PCMs, with perioperative cranial neuropathies exhibiting favorable recovery rates. Most essentially, the preselection of patients with hallmarks of brain stem affection and cavernous sinus infiltration should dictate whether to strive for a functionally oriented strategy in favor of radical resection

    High resolution ion chamber array delivery quality assurance for robotic radiosurgery: commissioning and validation

    Get PDF
    AbstractPurposeHigh precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.Methods and materialPreliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference⩽2%, distance-to-agreement⩽2mm, pass-rate⩾90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.ResultsThe 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1mm distance-to-agreement criterion while 2mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.ConclusionWe demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response
    corecore