    A self-organising mixture network for density modelling

    Get PDF
    A completely unsupervised mixture distribution network, namely the self-organising mixture network, is proposed for learning arbitrary density functions. The algorithm minimises the Kullback-Leibler information by means of stochastic approximation methods. The density functions are modelled as mixtures of parametric distributions such as Gaussian and Cauchy. The first layer of the network is similar to the Kohonen's self-organising map (SOM), but with the parameters of the class conditional densities as the learning weights. The winning mechanism is based on maximum posterior probability, and the updating of weights can be limited to a small neighbourhood around the winner. The second layer accumulates the responses of these local nodes, weighted by the learning mixing parameters. The network possesses simple structure and computation, yet yields fast and robust convergence. Experimental results are also presente

    Successful prediction of horse racing results using a neural network

    Get PDF
    Most application work within neural computing continues to employ multi-layer perceptrons (MLP). Though many variations of the fully interconnected feed-forward MLP, and even more variations of the back propagation learning rule, exist; the first section of the paper attempts to highlight several properties of these standard networks. The second section outlines an application-namely the prediction of horse racing result

    Ground penetrating radar migration with uncertain parameters

    Get PDF
    The focusing principle of Kirchoff migration is described. This allows the introduction of optical focusing techniques that can be used to focus migration. Three focus measures are described that are useful for optimising migration. Simple optimisation routines are implemented that model uncertainties in the migration parameters. The focus measures are then used as cast functions to be maximised. Results show that these measures are useful in optimising migration when there are uncertainties in the parameter

    Image processing applications using a novel parallel computing machine based on reconfigurable logic

    Get PDF
    Zelig is a 32 physical node fine-grained computer employing field-programmable gate arrays. Its application to the high speed implementation of various image pre-processing operations (in particular binary morphology) is described together with typical speed-up result

    OPTIma:simplifying calorimetry for proton computed tomography in high proton flux environments

    Get PDF
    Objective. Proton computed tomography (pCT) offers a potential route to reducing range uncertainties for proton therapy treatment planning, however the current trend towards high current spot scanning treatment systems leads to high proton fluxes which are challenging for existing systems. Here we demonstrate a novel approach to energy reconstruction, referred to as ‘de-averaging’, which allows individual proton energies to be recovered using only a measurement of their integrated energy without the need for spatial information from the calorimeter. Approach. The method is evaluated in the context of the Optimising Proton Therapy through Imaging (OPTIma) system which uses a simple, relatively inexpensive, scintillator-based calorimeter that reports only the integrated energy deposited by all protons within a cyclotron period, alongside a silicon strip based tracking system capable of reconstructing individual protons in a high flux environment. GEANT4 simulations have been performed to examine the performance of such a system at a modern commercial cyclotron facility using a σ ≈ 10 mm beam for currents in the range 10–50 pA at the nozzle. Main results. Apart from low-density lung tissue, a discrepancy of less than 1% on the Relative Stopping Power is found for all other considered tissues when embedded within a 150 mm spherical Perspex phantom in the 10–30 pA current range, and for some tissues even up to 50 pA. Significance. By removing the need for the calorimeter system to provide spatial information, it is hoped that the de-averaging approach can facilitate clinically relevant, cost effective and less complex calorimeter systems for performing high current pCTs

    Proton radiography and tomography with application to proton therapy

    Get PDF
    Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio (SPR) inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active that at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, its historical developments, the raft of modern prototype systems and the primary design issues

    Supervised learning based multimodal MRI brain tumour segmentation using texture features from supervoxels

    Get PDF
    BACKGROUND: Accurate segmentation of brain tumour in magnetic resonance images (MRI) is a difficult task due to various tumour types. Using information and features from multimodal MRI including structural MRI and isotropic (p) and anisotropic (q) components derived from the diffusion tensor imaging (DTI) may result in a more accurate analysis of brain images. METHODS: We propose a novel 3D supervoxel based learning method for segmentation of tumour in multimodal MRI brain images (conventional MRI and DTI). Supervoxels are generated using the information across the multimodal MRI dataset. For each supervoxel, a variety of features including histograms of texton descriptor, calculated using a set of Gabor filters with different sizes and orientations, and first order intensity statistical features are extracted. Those features are fed into a random forests (RF) classifier to classify each supervoxel into tumour core, oedema or healthy brain tissue. RESULTS: The method is evaluated on two datasets: 1) Our clinical dataset: 11 multimodal images of patients and 2) BRATS 2013 clinical dataset: 30 multimodal images. For our clinical dataset, the average detection sensitivity of tumour (including tumour core and oedema) using multimodal MRI is 86% with balanced error rate (BER) 7%; while the Dice score for automatic tumour segmentation against ground truth is 0.84. The corresponding results of the BRATS 2013 dataset are 96%, 2% and 0.89, respectively. CONCLUSION: The method demonstrates promising results in the segmentation of brain tumour. Adding features from multimodal MRI images can largely increase the segmentation accuracy. The method provides a close match to expert delineation across all tumour grades, leading to a faster and more reproducible method of brain tumour detection and delineation to aid patient management

    Proton-counting radiography for proton therapy: a proof of principle using CMOS APS technology

    Get PDF
    Despite the early recognition of the potential of proton imaging to assist proton therapy (Cormack 1963 J. Appl. Phys. 34 2722), the modality is still removed from clinical practice, with various approaches in development. For proton-counting radiography applications such as computed tomography (CT), the water-equivalent-path-length that each proton has travelled through an imaged object must be inferred. Typically, scintillator-based technology has been used in various energy/range telescope designs. Here we propose a very different alternative of using radiation-hard CMOS active pixel sensor technology. The ability of such a sensor to resolve the passage of individual protons in a therapy beam has not been previously shown. Here, such capability is demonstrated using a 36 MeV cyclotron beam (University of Birmingham Cyclotron, Birmingham, UK) and a 200 MeV clinical radiotherapy beam (iThemba LABS, Cape Town, SA). The feasibility of tracking individual protons through multiple CMOS layers is also demonstrated using a two-layer stack of sensors. The chief advantages of this solution are the spatial discrimination of events intrinsic to pixelated sensors, combined with the potential provision of information on both the range and residual energy of a proton. The challenges in developing a practical system are discussed

    Observations on metal concentrations in commercial landings of two species of tilapia (Oreochromis mossambicus and Oreochromis niloticus) from reservoirs in six river basins in Sri Lanka

    Full text link
    Samples of the muscle of two species of tilapia (Oreochromis mossambicus and O. niloticus; 17-20 cm length) were obtained from at least one reservoir in each of the six river basins (Aruvi Aru, Kala Oya, Kirindi Oya, Ma Oya, Mahaweli, and Walawe Ganga catchments) in Sri Lanka. The metals Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were consistently detected in the muscle tissue. Overall, there were few differences in the concentration of metals between the two species of fish, although there were also some statistically significant differences (p &lt; 0.05) in the concentrations of some metals in fish obtained from some of the reservoirs. Aruvi Aru stands out as a river basin in which the two fish species have significantly lower concentration of metals when compared to other river basins. The concentration of the metals studied were below WHO and FSANZ guideline values for fish, suggesting that the consumption of the metals found in tilapia from these reservoirs poses little risk to human health. <br /
    • …