10 research outputs found

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Radiographic union score for hip substantially improves agreement between surgeons and radiologists

    No full text
    Abstract Background Despite the prominence of hip fractures in orthopedic trauma, the assessment of fracture healing using radiographs remains subjective. The variability in the assessment of fracture healing has important implications for both clinical research and patient care. With little existing literature regarding reliable consensus on hip fracture healing, this study was conducted to determine inter-rater reliability between orthopedic surgeons and radiologists on healing assessments using sequential radiographs in patients with hip fractures. Secondary objectives included evaluating a checklist designed to assess hip fracture healing and determining whether agreement improved when reviewers were aware of the timing of the x-rays in relation to the patients’ surgery. Methods A panel of six reviewers (three orthopedic surgeons and three radiologists) independently assessed fracture healing using sequential radiographs from 100 patients with femoral neck fractures and 100 patients with intertrochanteric fractures. During their independent review they also completed a previously developed radiographic checklist (Radiographic Union Score for Hip (RUSH)). Inter and intra-rater reliability scores were calculated. Data from the current study was compared to the findings from a previously conducted study where the same reviewers, unaware of the timing of the x-rays, completed the RUSH score. Results The agreement between surgeons and radiologists for fracture healing was moderate for “general impression of fracture healing” in both femoral neck (ICC = 0.60, 95% CI: 0.42-0.71) and intertrochanteric fractures (0.50, 95% CI: 0.33-0.62). Using a standardized checklist (RUSH), agreement was almost perfect in both femoral neck (ICC = 0.85, 95% CI: 0.82-0.87) and intertrochanteric fractures (0.88, 95% CI: 0.86-0.90). We also found a high degree of correlation between healing and the total RUSH score using a Receiver Operating Characteristic (ROC) analysis, there was an area under the curve of 0.993 for femoral neck cases and 0.989 for intertrochanteric cases. Agreement within the radiologist group and within the surgeon group did not significantly differ in our analyses. In all cases, radiographs in which the time from surgery was known resulted in higher agreement scores compared to those from the previous study in which reviewers were unaware of the time the radiograph was obtained. Conclusions Agreement in hip fracture radiographic healing may be improved with the use of a standardized checklist and appears highly influenced by the timing of the radiograph. These findings should be considered when evaluating patient outcomes and in clinical studies involving patients with hip fractures. Future research initiatives are required to further evaluate the RUSH checklist

    A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy.

    No full text
    Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    corecore