15 research outputs found

    Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications

    Get PDF
    Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG) acquisition and heart rate (HR) measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG) and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 devices during 5-minute periods while at rest, reading aloud under observation, and playing a video game. Correlation between the 3 devices was determined, and Bland-Altman plots for all possible pairs of devices across all conditions assessed agreement. Results. Across conditions, all device pairs showed high correlations. Bland-Altman plots further revealed the Droid as a valid measure for HR acquisition. Across all conditions, the Droid compared to ECG, 95% of the data points (differences between devices) fell within the limits of agreement. Conclusion. The Android application provides valid HRs at varying levels of movement free mental/perceptual motor exertion. Lack of electrode patches or wireless sensor telemetric straps make it advantageous for use in mobile-cell-phone-delivered health promotion and wellness programs. Further validation is needed to determine its applicability while engaging in physical movement-related activities

    Towards local electromechanical probing of cellular and biomolecular systems in a liquid environment

    Full text link
    Electromechanical coupling is ubiquitous in biological systems with examples ranging from simple piezoelectricity in calcified and connective tissues to voltage-gated ion channels, energy storage in mitochondria, and electromechanical activity in cardiac myocytes and outer hair cell stereocilia. Piezoresponse force microscopy (PFM) has originally emerged as a technique to study electromechanical phenomena in ferroelectric materials, and in recent years, has been employed to study a broad range of non-ferroelectric polar materials, including piezoelectric biomaterials. At the same time, the technique has been extended from ambient to liquid imaging on model ferroelectric systems. Here, we present results on local electromechanical probing of several model cellular and biomolecular systems, including insulin and lysozyme amyloid fibrils, breast adenocarcinoma cells, and bacteriorhodopsin in a liquid environment. The specific features of SPM operation in liquid are delineated and bottlenecks on the route towards nanometer-resolution electromechanical imaging of biological systems are identified.Comment: 37 pages (including refs), 8 figure

    Electrochemical Growth of a Cu 2

    No full text

    Enhanced stability of enzymes adsorbed onto nanoparticles

    No full text
    We have discovered that the highly curved surface of C60 fullerenes enhances enzyme stability in strongly denaturing environments to a greater extent than flat supports. The half-life of a model enzyme, soybean peroxidase, adsorbed onto fullerenes at 95 °C was 117 min, ca. 2.5-fold higher than that of the enzyme adsorbed onto graphite flakes and ca. 13-fold higher than that of the native enzyme. Furthermore, this phenomenon is not unique to fullerenes, but can also be extended to other nanoscale supports including silica and gold nanoparticles. The enhanced stability was exploited in the preparation of highly active and stable polymer-nanocomposite films. The ability to enhance protein stability by interfacing them with nanomaterials may impact numerous fields ranging from the design of diagnostics, sensors, and nanocomposites to drug delivery

    A novel protocol allowing oral delivery of a protein complement inhibitor that subsequently targets to inflamed colon mucosa and ameliorates murine colitis

    No full text
    Summary While there is evidence of a pathogenic role for complement in inflammatory bowel disease, there is also evidence for a protective role that relates to host defence and protection from endotoxaemia. There is thus concern regarding the use of systemic complement inhibition as a therapeutic strategy. Local delivery of a complement inhibitor to the colon by oral administration would ameliorate such concerns, but while formulations exist for oral delivery of low molecular weight drugs to the colon, they have not been used successfully for oral delivery of proteins. We describe a novel pellet formulation consisting of cross-linked dextran coated with an acrylic co-polymer that protects the complement inhibitor CR2-Crry from destruction in the gastrointestinal tract. CR2-Crry containing pellets administered by gavage, were characterized using a therapeutic protocol in a mouse model of dextran sulphate sodium (DSS)-induced colitis. Oral treatment of established colitis over a 5-day period significantly reduced mucosal inflammation and injury, with similar therapeutic benefit whether or not the proton pump inhibitor, omeprazole, was co-administered. Reduction in injury was associated with the targeting of CR2-Crry to the mucosal surface and reduced local complement activation. Treatment had no effect on systemic complement activity. This novel method for oral delivery of a targeted protein complement inhibitor will reduce systemic effects, thereby decreasing the risk of opportunistic infection, as well as lowering the required dose and treatment cost and improving patient compliance. Furthermore, the novel delivery system described here may provide similar benefits for administration of other protein-based drugs, such as anti-tumour necrosis factor-α antibodies
    corecore