31 research outputs found

    Sistema de inicio de sesión único para aplicaciones en departamento Administrativo Financiero del Instituto de Ciencias Forenses de Guatemala

    Get PDF
    Implementar un único sistema de autenticación para las aplicaciones en Departamento Administrativo Financiero (DAF) del Instituto Nacional de Ciencias Forenses de Guatemala (INACIF), así integrar, adecuar y desplegar las diferentes aplicaciones del DAF con el software de SSO Keycloak para la administración de identificación y acceso centralizado e implementar componente para homologar los permisos de usuarios locales con usuarios de directorio activo, los usuarios al autenticarse a través de SSO mantienen los permisos anteriores

    Robust Metabolite Quantification from J-Compensated 2D 1H-13C-HSQC Experiments

    Get PDF
    The spectral resolution of 2D H-1-C-13 heteronuclear single quantum coherence (H-1-C-13-HSQC) nuclear magnetic resonance (NMR) spectra facilitates both metabolite identification and quantification in nuclear magnetic resonance-based metabolomics. However, quantification is complicated by variations in magnetization transfer, which among others originate mainly from scalar coupling differences. Methods that compensate for variation in scalar coupling include the generation of calibration factors for individual signals or the use of additional pulse sequence schemes such as quantitative HSQC (Q-HSQC) that suppress the J(CH)-dependence by modulating the polarization transfer delays of HSQC or, additionally, employ a pure-shift homodecoupling approach in the 1(H) dimension, such as Quantitative, Perfected and Pure Shifted HSQC (QUIPU-HSQC). To test the quantitative accuracy of these three methods, employing a 600 MHz NMR spectrometer equipped with a helium cooled cryoprobe, a Latin-square design that covered the physiological concentration ranges of 10 metabolites was used. The results show the suitability of all three methods for the quantification of highly abundant metabolites. However, the substantially increased residual water signal observed in QUIPU-HSQC spectra impeded the quantification of low abundant metabolites located near the residual water signal, thus limiting its utility in high-throughput metabolite fingerprinting studies

    Recording of bipolar multichannel ECGs by a smartwatch

    No full text
    Aims:\it Aims: Feasibility study of accurate three lead ECG recording (Einthoven I, II and III) using an Apple Watch Series 4. Methods:\it Methods: In 50 healthy subjects (18 male; age: 40 ±\pm 12 years) without known cardiac disorders, a 12-lead ECG and three bipolar ECGs, corresponding to Einthoven leads I, II and III were recorded using an Apple Watch Series 4. Einthoven I was recorded with the watch on the left wrist and the right index finger on the crown, Einthoven II with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III with the watch on the left lower abdomen and the left index finger on the crown. Four experienced cardiologists were independently asked to assign the watch ECGs to Einthoven leads from 12-lead ECG for each subject. Results:\it Results: All watch ECGs showed an adequate signal quality with 134 ECGs of good (89%) and 16 of moderate signal quality (11%). Ninety-one percent of all watch ECGs were assigned correctly to corresponding leads from 12-lead ECG. Thirty-nine subjects (78%) were assigned correctly by all cardiologists. All assignment errors occurred in patients with similar morphologies and amplitudes in at least two of the three recorded leads. Erroneous assignment of all watch ECGs to leads from standard ECG occurred in no patient. Conclusion:\it Conclusion: Recording of Einthoven leads I-III by a smartwatch is accurate and highly comparable to standard ECG. This might contribute to an earlier detection of cardiac disorders, which are associated with repolarization abnormalities or arrhythmias

    Single-lead ECG recordings including Einthoven and Wilson leads by a Smartwatch

    No full text
    Background: Smartwatches that are able to record a bipolar ECG and Einthoven leads were recently described. Nevertheless, for detection of ischemia or other cardiac diseases more leads are required, especially Wilson's chest leads. Objectives: Feasibility study of six single-lead smartwatch (Apple Watch Series 4) ECG recordings including Einthoven (I, II, III) and Wilson-like pseudo-unipolar chest leads (Wr, Wm, Wl). Methods: In 50 healthy subjects (16 males; age: 36 ±\pm 11 years, mean ±\pm SD) without known cardiac disorders, a standard 12-lead ECG and a six single-lead ECG using an Apple Watch Series 4 were performed under resting conditions. Recording of Einthoven I was performed with the watch on the left wrist and the right index finger on the crown, Einthoven II was recorded with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III was recorded with the watch on the left lower abdomen and the left index finger on the crown. Wilson-like chest leads were recorded corresponding to the locations of V1 (Wr), V4 (Wm) and V6 (Wl) in the standard 12-lead ECG. Wr was recorded in the fourth intercostal space right parasternal, Wm was recorded in the fifth intercostal space on the midclavicular line, and Wl was recorded in the fifth intercostal space in left midaxillary line. For all Wilson-like chest lead recordings, the smartwatch was placed on the described three locations on the chest, the right index finger was placed on the crown and the left hand encompassed the right wrist. Both hands and forearms also had contact to the chest. Three experienced cardiologists were independently asked to allocate three bipolar limb smartwatch ECGs to Einthoven I–III leads, and three smartwatch Wilson-like chest ECGs (Wr, Wm, Wl) to V1, V4 and V6 in the standard 12-lead ECG for each subject. Results: All 300 smartwatch ECGs showed a signal quality useable for diagnostics with 281 ECGs of good signal quality (143 limb lead ECGs (95%), 138 chest lead ECGs (92%). Nineteen ECGs had a moderate signal quality (7 limb lead ECGs (5%), 12 chest lead ECGs (8%)). One-hundred percent of all Einthoven and 92% of all Wilson-like smartwatch ECGs were allocated correctly to corresponding leads from 12-lead ECG. Forty-six subjects (92%) were assigned correctly by all cardiologists. Allocation errors were due to similar morphologies and amplitudes in at least two of the three recorded Wilson-like leads. Despite recording with a bipolar smartwatch device, morphology of all six leads was identical to standard 12-lead ECG. In two patients with acute anterior myocardial infarction, all three cardiologists recognized the ST-elevations in Wilson-like leads and assumed an occluded left anterior descending coronary artery correctly. Conclusion: Consecutive recording of six single-lead ECGs including Einthoven and Wilson-like leads by a smartwatch is feasible with good ECG signal quality. Thus, this simulated six-lead smartwatch ECG may be useable for the detection of cardiac diseases necessitating more than one ECG lead like myocardial ischemia or more complex cardia arrhythmias

    Catheter navigation by intracardiac echocardiography enables zero-fluoroscopy linear lesion formation and bidirectional cavotricuspid isthmus block in patients with typical atrial flutter

    No full text
    Abstract Introduction One of the most helpful aspects of intracardiac echocardiography (ICE) implementation in electrophysiological studies (EPS) is the real-time visualisation of catheters and cardiac structures. In this prospective study, we investigated ICE-guided zero-fluoroscopy catheter navigation during radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL). Methods and results Thirty consecutive patients (mean age 72.9 ± 11.4 years, 23 male) with ongoing (n = 23) or recent CTI-dependent AFL underwent an EPS, solely utilizing ICE for catheter navigation. Zero-fluoroscopy EPS could be successfully accomplished in all patients. Mean EPS duration was 41.4 ± 19.9 min, and mean ablation procedure duration was 20.8 ± 17.1 min. RF ablation was applied for 6.0 ± 3.1 min (50W, irrigated RF ablation). Echocardiographic parameters, such as CTI length, prominence of the Eustachian ridge (ER), and depth of the CTI pouch on the ablation plane, were assessed to analyse their correlation with EPS- or ablation procedure duration. The CTI pouch was shallower in patients with an ablation procedure duration above the median (4.8 ± 1.1 mm vs. 6.4 ± 0.9 mm, p = 0.04), suggesting a more lateral ablation plane in these patients, where the CTI musculature is stronger. CTI length or ER prominence above the respective median did not correlate with longer EPS duration. Conclusions Zero-fluoroscopy CTI ablation guided solely by intracardiac echocardiography in patients with CTI-dependent AFL is feasible and safe. ICE visualisation may help to localise the optimal ablation plane, detect and correct poor tissue contact of the catheter tip, and recognise early potential complications during the ablation procedure. Graphical Abstrac

    Improved Clinical Risk Stratification in Patients with Long QT Syndrome? Novel Insights from Multi-Channel ECGs.

    No full text
    BACKGROUND:We investigated whether multichannel ECG-recordings are useful to risk-stratify patients with congenital long-QT syndrome (LQTS) for risk of sudden cardiac death under optimized medical treatment. METHODS:In 34 LQTS-patients (11 male; age 31±13 years, QTc 478±51ms; LQT1 n = 8, LQT2 n = 15) we performed a standard 12-channel ECG and a 120-channel body surface potential mapping. The occurrence of clinical events (CE; syncope, torsade de pointes (TdP), sudden cardiac arrest (SCA)) was documented and correlated with different ECG-parameters in all lead positions. RESULTS:Seven patients developed TdP, four survived SCA and 12 experienced syncope. 12/34 had at least one CE. CE was associated with a longer QTc-interval (519±43ms vs. 458±42ms; p = 0.001), a lower T-wave integral (TWI) on the left upper chest (-1.2±74.4mV*ms vs. 63.0±29.7mV*ms; p = 0.001), a lower range of T-wave amplitude (TWA) in the region of chest lead V8 (0.10±0.08mV vs. 0.18±0.07mV; p = 0.008) and a longer T-peak-T-end time (TpTe) in lead V1 (98±23ms vs. 78±26ms; p = 0.04). Receiver-operating-characteristic (ROC) analyses revealed a sensitivity of 96% and a specificity of 75% (area under curve (AUC) 0.89±0.06, p = 0.001) at a cut-off value of 26.8mV*ms for prediction of CE by TWI, a sensitivity of 86% and a specificity of 83% at a cut-off value of 0.11mV (AUC 0.83±0.09, p = 0.002) for prediction of CE by TWA and a sensitivity of 83% and a specificity of 73% at a cut-off value of 87ms (AUC 0.80±0.07, p = 0.005) for prediction of CE by TpTe. CONCLUSIONS:Occurrence of CE in LQTS-patients seems to be associated with a prolonged, low-amplitude T-wave
    corecore