10 research outputs found

    Three-dimensional echocardiography and 2D-3D speckle tracking imaging in chronic pulmonary hypertension. diagnostic accuracy in detecting hemodynamic signs of RV failure

    Get PDF
    Background and objective. Our aim was to compare three-dimensional (3D) and 2D and 3D speckle tracking (2D-STE, 3D-STE) echocardiographic parameters with conventional right ventricular (RV) indexes in patients with chronic pulmonary hypertension (PH), and investigate whether these techniques could result in better correlation with hemodynamic variables indicative of heart failure. Methods. Seventy-three adult patients (mean age, 53±13 years; 44% male) with chronic PH of different etiologies were studied by echocardiography and cardiac catheterization (25 precapillary PH from pulmonary arterial hypertension, 23 obstructive pulmonary heart disease, and 23 postcapillary PH from mitral regurgitation). Thirty healthy subjects (mean age, 54±15 years; 43% male) served as controls. Standard 2D measurements (RV-FAC -fractional area change-, TAPSE -tricuspid annular plane systolic excursion-) and mitral and tricuspid tissue Doppler annular velocities were obtained. RV 3D volumes, and global and regional ejection fraction (3D-RVEF) were determined. RV strains were calculated by 2D-STE and 3D-STE. Results. RV 3D global-free-wall longitudinal strain (3DGFW-RVLS), 2D global-free-wall longitudinal strain (GFW-RVLS), apical-free-wall longitudinal strain (AFW-RVLS), basal-free-wall longitudinal strain (BFW-RVLS), and 3D-RVEF were lower in patients with pre-capillary PH (p<0.0001) and post-capillary PH (p<0.01) compared to controls. 3DGFW-RVLS (HR 4.6, 95% CI 2.79-8.38, p=0.004) and 3D-RVEF (HR 5.3, 95% CI 2.85-9.89, p=0.002) were independent predictors of mortality. ROC curves showed that the thresholds offering an adequate compromise between sensitivity and specificity for detecting hemodynamic signs of RV failure were 39% for 3D-RVEF (AUC 0.89), -17% for 3DGFW-RVLS (AUC 0.88), -18% for GFW-RVLS (AUC 0.88), -16% for AFW-RVLS (AUC 0.85), 16mm for TAPSE (AUC 0.67), and 38% for RV-FAC (AUC 0.62). Conclusions. In chronic PH, 3D, 2D-STE and 3D-STE parameters indicate global and regional RV dysfunction that is associated with RV failure hemodynamics better than conventional echo indices

    A case report of myocardial infarction with non-obstructive coronary artery disease: Graves' disease-induced coronary artery vasospasm

    No full text
    Background: Coronary artery spasm can occur either in response to drugs or toxins. This response may result in hyper-reactivity of vascular smooth muscles or may occur spontaneously as a result of disorders in the coronary vasomotor tone. Hyperthyroidism is associated with coronary artery spasm. Case summary: A 49-year-old female patient with a 2-day history of intermittent chest pain and electrocardiographic evidence of myocardial ischaemia was referred for emergency coronary angiography. This revealed severe right coronary artery (RCA) and left main (LM) coronary artery ostial vasospasm, both subsequently relieved with administration of multiple doses intracoronary nitroglycerine. Intravascular optical coherence tomography showed absence of atherosclerosis and no evidence of thrombus or dissection confirming the diagnosis of coronary artery vasospasm. Laboratory tests of the thyroid function were performed immediately after coronary angiography revealing Graves' disease as the cause of vasospasm. Discussion: Our case represents a rare presentation of Graves' disease-induced RCA and LM coronary artery ostial vasospasm. In patients with coronary artery vasospasm thyroid function study should be mandatory, especially in young female patients

    Echocardiographic findings in simple and complex patent foramen ovale before and after transcatheter closure

    No full text
    Aims. Percutaneous closure of patent foramen ovale (PFO) in cryptogenic cerebrovascular events is an alternative to medical therapy. The interpretation of residual shunts after implantation of different devices for PFO with different morphologies is controversial. Methods and results. Transcatheter PFO closure was performed in 123 patients with a history of ≄1 paradoxical embolism using three different devices: Amplatzer (n=46), Figulla Occlutech (n=41) and Atriasept Cardia (n=36). Fifty-six patients presented with simple PFO and 67 patients had complex morphologies. All patients were studied with contrast-enhanced transesophageal echocardiography (TEE) before interventional procedure and thereafter at 1 and 6 months and every 6 to 12 months in case of incomplete closure. Definite closure was confirmed in at least two consecutive TEE studies. Various PFO morphologies were identified by TEE before device implantation. The device size to PFO diameter ratio was significantly increased in patients with complex PFO compared to those patients with a simple PFO morphology (p<0.05). The difference between the closure rate of S-PFO and C-PFO concerning each device type was significant (Amplatzer p=0.0027, Figulla p=0.0043, Atriasept p<0.01). The mean follow up period was 3.4 years (median 2.7 years) with a cerebrovascular re-event-rate of 2.4% per year. In three patients thrombi were detected in the six month TEE controls and resolved after medical therapy. In three other patients the implantation of an adjunctive device was necessary for residual shunt. Conclusion. In our series of patients the closure rate was dependent on PFO morphology more than occluder size and type. An adjunctive device was implanted in selected cases

    Use of cardiac imaging in chronic coronary syndromes: the EURECA Imaging registry.

    No full text
    corecore