3 research outputs found

    Возможности импульсной осциллометрии в диагностике обструкции дыхательных путей легкой степени выраженности

    Get PDF
    The aim of this study was to investigate a role of impulse oscillometry (IO) for detection of mild bronchial obstruction. Methods. The study involved 87 patients with different respiratory diseases. Bronchial obstruction according to spirometry results was found in 50 patients (the study group). The control group patients did not demonstrate any abnormalities in spirometry, body plethysmography and lung diffusing test. Results. An abnormal increase in frequency-dependent resistive component of respiratory impedance (Rrs) at the oscillation frequency of 5Hrz and 10 Hrz [both the relative oscillation frequency (Rrs5–Rrs20)/Rrs20 and the absolute oscillation frequency (Rrs5–Rrs20)] was found in patients with mild bronchial obstruction. The resonance frequency (fres) shifted towards higher frequency; reactance area (AX) increase and expiratory airflow (DXrs5) limitation were also found in those patients. Rrs5, Rrs20, and the reactive resistance (Xrs5) were within the normal range. Conclusion. Rrs5 и Xrs5 could detect mild bronchial obstruction only in 32 % of the cases. AX is more useful parameter as it increased in 64% of the patients. The severity of bronchial obstruction diagnosed with IO or spirometry was not identical in some cases.Нередко начальным проявлением заболеваний легких являются функциональные нарушения, а именно – нарушение проходимости бронхов. Выявление обструктивного типа вентиляционных расстройств на ранних стадиях является важной клинической задачей, т. к. позволяет своевременно диагностировать болезнь и начать лечение, улучшив тем самым прогноз заболевания. Одним из самых доступных методов, позволяющих выявлять бронхиальную обструкцию, является спирометрия. Необходимое условие проведения спирометрии – правильное выполнение дыхательных маневров, однако при этом требуется хорошая кооперация пациента с медицинским персоналом, что не всегда выполнимо. Импульсная осциллометрия (ИОМ) отличается тем, что измерения осуществляются при спокойном дыхании, активного участия пациента не требуется. Однако остается много неизученных и спорных вопросов, касающихся интерпретации результатов ИОМ. Целью данного исследования явилось изучение возможности ИОМ при диагностике обструкции дыхательных путей легкой степени выраженности. Материалы и методы. Обследованы пациенты (n = 87) с разнообразной бронхолегочной патологией, при этом выявлены вентиляционные нарушения обструктивного типа легкой степени (n = 50). В группе сравнения (n = 37) нарушений по данным спирометрии, бодиплетизмографии и диффузионного теста не отмечено. Результаты. У больных с легкой степенью бронхиальной обструкции, установленной по данным спирометрии, наблюдалось патологическое увеличение частотной зависимости резистивного компонента дыхательного импеданса (Rrs) при частоте осцилляций 5 и 20 Гц (как относительной (Rrs5–Rrs20) / Rrs20, так и абсолютной (Rrs5–Rrs20)), смещение резонансной частоты (fres) в область высоких частот, увеличение площади реактанса (АХ) и экспираторное ограничение потока (DXrs5) при сохранении в пределах нормальных значений Rrs5, Rrs20 и реактивного сопротивления (Xrs5). Заключение. Показано, что при использовании базовых параметров Rrs5 и Xrs5 обструкция легкой степени выраженности, установленная при помощи традиционных функциональных методов, наблюдалась только в 32 % случаев. АХ явился более информативным методом, поскольку изменялся значительно чаще – его увеличение зарегистрировано у 64 % пациентов. Выраженность обструктивных нарушений по данным ИОМ не всегда совпадало с выраженностью нарушений, определяемых при помощи спирометрии

    Effect of Chitosan and Amphiphilic Polymers on the Photosensitizing and Spectral Properties of Rose Bengal

    No full text
    The influence of chitosan (CS) and amphiphilic polymers (AP: pluronic F108 and polyvinylpyrrolidone (PVP)) on the photocatalytic activity of rose bengal (RB) in a model reaction of tryptophan photo-oxidation in phosphate-buffered saline (PBS) was studied. It was shown that in the presence of CS, the effective rate constant keff of tryptophan photo-oxidation catalyzed by RB in PBS solution decreases by a factor of two. This is due to the ionic interaction of the RB with the chitosan. Rose bengal in a slightly acidic environment (pH 4.5) passes into a neutral lactone form, which sharply reduces the photosensitizing properties of the dye. It was demonstrated that the introduction of AP into a solution containing RB and CS prevents direct interaction between RB and CS. This is evidenced by the presence of photocatalytic activity of the dye in the RB-AP-CS systems, as well as bathochromic shifts of the main absorption bands of the dye, and an increase in the optical density and luminescence intensity of the RB when AP is introduced into a buffer solution containing RB and chitosan. The presence of RB-CS and RB-AP interaction in aqueous and PBS media is confirmed by the increase in the degree of fluorescence anisotropy (r) of these binary systems. In an aqueous solution, the value of r for the RB-F108-CS system decreases by a factor of 3.5 (compared to the value of r for the RB-CS system), which is associated with the localization of the dye in pluronic micelles. In PBS, the fluorescence anisotropy is practically the same for all systems, which is related to the stability of the dye structure in this medium. The presence of interaction between RB and AP in aqueous solutions was confirmed by the proton NMR method. In addition, the formation of RB-F108 macromolecular complexes, which form associates during solution concentration (in particular, during evaporation), was shown by AFM. Such RB-AP-CS systems may be promising for practical application in the treatment of local foci of infections by aPDT

    LUMINEU: a search for neutrinoless double beta decay based on ZnMoO 4 scintillating bolometers

    No full text
    The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in 100Mo by means of a large array of scintillating bolometers based on ZnMoO4 crystals enriched in 100Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the α/β discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kgXyears, setting the bases for a next generation 0v2β decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern
    corecore