15 research outputs found

    New strategy for the identification of prostate cancer: The combination of Proclarix and the prostate health index

    Get PDF
    Prostate health index (PHI) and, more recently, Proclarix have been proposed as serum biomarkers for prostate cancer (PCa). In this study, we aimed to evaluate Proclarix and PHI for predicting clinically significant prostate cancer (csPCa)

    Evaluation of Proclarix in the diagnostic work‐up of prostate cancer

    Get PDF
    Objectives: The use of multiparametric magnetic resonance imaging (mpMRI) has been widely adopted in the diagnostic work‐up for suspicious prostate cancer (PCa) and is recommended in most current guidelines. However, mpMRI lesions are often indeterminate and/or turn out to be false‐positive on prostate biopsy. The aim of this work was to evaluate Proclarix, a biomarker test for the detection of relevant PCa, regarding its diagnostic value in all men before biopsy and in men with indeterminate lesions on mpMRI (PI‐RADS 3) during work‐up for PCa. Materials and Methods: Men undergoing mpMRI‐targeted and systematic biopsy of the prostate were prospectively enrolled. The Proclarix test was evaluated for the detection accuracy of clinically significant PCa (csPCa) defined as Grade Group ≥ 2 and its association to mpMRI results. Further, Proclarix's performance was also tested when adapted to prostate volume (Proclarix density) and performance compared to PSA density (PSAD). Results: A total of 150 men with a median age of 65 years and median PSA of 5.8 ng/mL were included in this study. CsPCa was diagnosed in 65 (43%) men. Proclarix was significantly associated with csPCa and higher PI‐RADS score (p < 0.001). At the pre‐defined cut‐off of 10%, Proclarix's sensitivity for csPCa was 94%, specificity 19%, negative predictive value 80% and positive predictive value 47%. Proclarix density showed the highest AUC for the detection of csPCa of 0.77 (95%CI: 0.69–0.85) compared to PSA, PSAD and Proclarix alone. Proclarix was able to identify all six csPCa in men with PI‐RADS 3 lesions (n = 28), whereas PSAD missed two out of six. At optimized cut‐offs, Proclarix density outperformed PSAD by potentially avoiding 41% of unnecessary biopsies. Conclusion: Proclarix demonstrates high sensitivity in detecting csPCa but may still result in unnecessary biopsies. However, Proclarix density was able to outperform PSAD and Proclarix and was found to be useful in men with PI‐RADS 3 findings by safely avoiding unnecessary biopsies without missing csPCa

    Analytical performance of thrombospondin-1 and cathepsin D immunoassays part of a novel CE-IVD marked test as an aid in the diagnosis of prostate cancer.

    No full text
    The Prostate Specific Antigen (PSA) test suffers from low specificity for the diagnosis of Prostate Cancer (PCa). We originally discovered two cancer-related proteins thrombospondin-1 (THBS1) and cathepsin D (CTSD) using a mass-spectrometry-based proteomics approach. The two serum proteins were shown to improve the diagnosis of high-grade PCa. Thus, we developed quantitative ELISAs for the determination of their concentration in human serum. Here we report their analytical performance in terms of limit of detection, specificity, precision, linearity and interferences, which were determined based on CLSI guidelines. Further, we investigated the influence of pre-analytical factors on concentration measurements. For this, blood from 4-6 donors was collected in different tubes and stored at room temperature for different times prior to centrifugation at different centrifugal forces and temperatures. Stability of THBS1 and CTSD under different storage temperatures was also evaluated. Our results show that the assays are specific, linear and sensitive enough to allow measurement of clinical samples. Precision in terms of repeatability and total within-laboratory coefficient of variation (CV) are 5.5% and 8.1% for THBS1 and 4.3% and 7.2% for CTSD, respectively. Relative laboratory-to-laboratory differences were -6.3% for THBS1 and -3% for CTSD. Both THBS1 and CTSD were stable in serum samples, with 80-120% recoveries of concentrations across donors, sample preparation and storage. In conclusion, the ELISAs as part of the novel commercial in vitro diagnostic test Proclarix are suitable for the use in clinical practice. THBS1 and CTSD can be accurately measured for their intended use independent of the lot and laboratory when conditions consistent with routine practice for PSA sampling and storage are used

    Use of MS-GUIDE for identification of protein biomarkers for risk stratification of patients with prostate cancer

    Full text link
    BACKGROUND Non-invasive liquid biopsies could complement current pathological nomograms for risk stratification of prostate cancer patients. Development and testing of potential liquid biopsy markers is time, resource, and cost-intensive. For most protein targets, no antibodies or ELISAs for efficient clinical cohort pre-evaluation are currently available. We reasoned that mass spectrometry-based prescreening would enable the cost-effective and rational preselection of candidates for subsequent clinical-grade ELISA development. METHODS Using Mass Spectrometry-GUided Immunoassay DEvelopment (MS-GUIDE), we screened 48 literature-derived biomarker candidates for their potential utility in risk stratification scoring of prostate cancer patients. Parallel reaction monitoring was used to evaluate these 48 potential protein markers in a highly multiplexed fashion in a medium-sized patient cohort of 78 patients with ground-truth prostatectomy and clinical follow-up information. Clinical-grade ELISAs were then developed for two of these candidate proteins and used for significance testing in a larger, independent patient cohort of 263 patients. RESULTS Machine learning-based analysis of the parallel reaction monitoring data of the liquid biopsies prequalified fibronectin and vitronectin as candidate biomarkers. We evaluated their predictive value for prostate cancer biochemical recurrence scoring in an independent validation cohort of 263 prostate cancer patients using clinical-grade ELISAs. The results of our prostate cancer risk stratification test were statistically significantly 10% better than results of the current gold standards PSA alone, PSA plus prostatectomy biopsy Gleason score, or the National Comprehensive Cancer Network score in prediction of recurrence. CONCLUSION Using MS-GUIDE we identified fibronectin and vitronectin as candidate biomarkers for prostate cancer risk stratification

    Use of MS-GUIDE for identification of protein biomarkers for risk stratification of patients with prostate cancer

    No full text
    Background Non-invasive liquid biopsies could complement current pathological nomograms for risk stratification of prostate cancer patients. Development and testing of potential liquid biopsy markers is time, resource, and cost-intensive. For most protein targets, no antibodies or ELISAs for efficient clinical cohort pre-evaluation are currently available. We reasoned that mass spectrometry-based prescreening would enable the cost-effective and rational preselection of candidates for subsequent clinical-grade ELISA development. Methods Using Mass Spectrometry-GUided Immunoassay DEvelopment (MS-GUIDE), we screened 48 literature-derived biomarker candidates for their potential utility in risk stratification scoring of prostate cancer patients. Parallel reaction monitoring was used to evaluate these 48 potential protein markers in a highly multiplexed fashion in a medium-sized patient cohort of 78 patients with ground-truth prostatectomy and clinical follow-up information. Clinical-grade ELISAs were then developed for two of these candidate proteins and used for significance testing in a larger, independent patient cohort of 263 patients. Results Machine learning-based analysis of the parallel reaction monitoring data of the liquid biopsies prequalified fibronectin and vitronectin as candidate biomarkers. We evaluated their predictive value for prostate cancer biochemical recurrence scoring in an independent validation cohort of 263 prostate cancer patients using clinical-grade ELISAs. The results of our prostate cancer risk stratification test were statistically significantly 10% better than results of the current gold standards PSA alone, PSA plus prostatectomy biopsy Gleason score, or the National Comprehensive Cancer Network score in prediction of recurrence. Conclusion Using MS-GUIDE we identified fibronectin and vitronectin as candidate biomarkers for prostate cancer risk stratification

    Development and clinical testing of individual immunoassays for the quantification of serum glycoproteins to diagnose prostate cancer

    Get PDF
    Prostate Cancer (PCa) diagnosis is currently hampered by the high false-positive rate of PSA evaluations, which consequently may lead to overtreatment. Non-invasive methods with increased specificity and sensitivity are needed to improve diagnosis of significant PCa. We developed and technically validated four individual immunoassays for cathepsin D (CTSD), intercellular adhesion molecule 1 (ICAM1), olfactomedin 4 (OLFM4), and thrombospondin 1 (THBS1). These glycoproteins, previously identified by mass spectrometry using a Pten mouse model, were measured in clinical serum samples for testing the capability of discriminating PCa positive and negative samples. The development yielded 4 individual immunoassays with inter and intra-variability (CV) <15% and linearity on dilution of the analytes. In serum, ex vivo protein stability (<15% loss of analyte) was achieved for a duration of at least 24 hours at room temperature and 2 days at 4°C. The measurement of 359 serum samples from PCa positive (n = 167) and negative (n = 192) patients with elevated PSA (2-10 ng/ml) revealed a significantly improved accuracy (P <0.001) when two of the glycoproteins (CTSD and THBS1) were combined with %fPSA and age (AUC = 0.8109; P <0.0001; 95% CI = 0.7673-0.8545). Conclusively, the use of CTSD and THBS1 together with commonly used parameters for PCa diagnosis such as %fPSA and age has the potential to improve the diagnosis of PCa

    Evaluation of Proclarix in the diagnostic work‐up of prostate cancer

    No full text
    Abstract Objectives The use of multiparametric magnetic resonance imaging (mpMRI) has been widely adopted in the diagnostic work‐up for suspicious prostate cancer (PCa) and is recommended in most current guidelines. However, mpMRI lesions are often indeterminate and/or turn out to be false‐positive on prostate biopsy. The aim of this work was to evaluate Proclarix, a biomarker test for the detection of relevant PCa, regarding its diagnostic value in all men before biopsy and in men with indeterminate lesions on mpMRI (PI‐RADS 3) during work‐up for PCa. Materials and Methods Men undergoing mpMRI‐targeted and systematic biopsy of the prostate were prospectively enrolled. The Proclarix test was evaluated for the detection accuracy of clinically significant PCa (csPCa) defined as Grade Group ≥ 2 and its association to mpMRI results. Further, Proclarix's performance was also tested when adapted to prostate volume (Proclarix density) and performance compared to PSA density (PSAD). Results A total of 150 men with a median age of 65 years and median PSA of 5.8 ng/mL were included in this study. CsPCa was diagnosed in 65 (43%) men. Proclarix was significantly associated with csPCa and higher PI‐RADS score (p < 0.001). At the pre‐defined cut‐off of 10%, Proclarix's sensitivity for csPCa was 94%, specificity 19%, negative predictive value 80% and positive predictive value 47%. Proclarix density showed the highest AUC for the detection of csPCa of 0.77 (95%CI: 0.69–0.85) compared to PSA, PSAD and Proclarix alone. Proclarix was able to identify all six csPCa in men with PI‐RADS 3 lesions (n = 28), whereas PSAD missed two out of six. At optimized cut‐offs, Proclarix density outperformed PSAD by potentially avoiding 41% of unnecessary biopsies. Conclusion Proclarix demonstrates high sensitivity in detecting csPCa but may still result in unnecessary biopsies. However, Proclarix density was able to outperform PSAD and Proclarix and was found to be useful in men with PI‐RADS 3 findings by safely avoiding unnecessary biopsies without missing csPCa

    Stability experiments.

    No full text
    <p>Stability of CTSD, ICAM1, OLFM4, and THBS1 in serum stored at room temperature (RT), 4°C or 1 up to 3 freeze and thaw (F/T) cycles, respectively. Shown are the mean (SD; error bars) measured protein concentrations (as a percentage of the original values) in 5 different samples.</p
    corecore