1,595 research outputs found

    Galactic-Center Hyper-Shell Model for the North Polar Spurs

    Get PDF
    The bipolar-hyper shell (BHS) model for the North Polar Spurs (NPS-E, -W, and Loop I) and counter southern spurs (SPS-E and -W) is revisited based on numerical hydrodynamical simulations. Propagations of shock waves produced by energetic explosive events in the Galactic Center are examined. Distributions of soft X-ray brightness on the sky at 0.25, 0.7, and 1.5 keV in a +/-50 deg x +/-50 deg region around the Galactic Center are modeled by thermal emission from high-temperature plasma in the shock-compressed shell considering shadowing by the interstellar HI and H2 gases. The result is compared with the ROSAT wide field X-ray images in R2, 4 and 6 bands. The NPS and southern spurs are well reproduced by the simulation as shadowed dumbbell-shaped shock waves. We discuss the origin and energetics of the event in relation to the starburst and/or AGN activities in the Galactic Center. [ High resolution pdf is available at http://www.ioa.s.u-tokyo.ac.jp/~sofue/htdocs/2016bhs/ ]Comment: 13 pages, 20 figures; To appear in MNRA

    Physicochemical influence on the spatial distribution of faecal bacteria and polychaetes in the Densu Estuary, Ghana

    Get PDF
    Coastal ecosystems are increasingly impacted by man-made disturbances including pollution from agriculture, aquaculture and municipal waste. This study employed multiple ecological indicators to assess environmental quality of the Densu Estuary and understanding of environmental controls on the spatial distribution of organisms. Physicochemical parameters were measured in situ. Water and sediment samples were collected from ten stations and analysed for nutrients, total suspended solids and organisms using standard methods. The water quality index for the Densu Estuary ranged from 359.5 to 484.4, suggesting an unhealthy ecosystem. The abundance of indicator species, e.g. faecal bacteria (Escherichia coli, Enterococcus species) and polychaetes (Capitella and Nereis species) varied significantly (p<0.05) among stations. Contaminated sites are located landwards with high human impacts. Faecal bacteria and polychaete abundance correlated significantly (p<0.05) with the respective physicochemical parameters. Canonical analysis (74.11%) showed the physicochemical influence on the spatial distribution of species. The pH significantly (p<0.05) controlled the spatial distribution of faecal bacteria and polychaetes in the Densu Estuary. The results suggest environmental pollution in the Densu Estuary, useful baseline information for effective legislation towards its sustainable management

    Development of a dose distribution shifter to fit inside the collimator of a Boron Neutron Capture Therapy irradiation system to treat superficial tumours

    Get PDF
    The Kansai BNCT Medical Center has a cyclotron based epithermal neutron source for clinical Boron Neutron Capture Therapy. The system accelerates a proton to an energy of 30 MeV which strikes a beryllium target producing fast neutrons which are moderated down to epithermal neutrons for BNCT use. While clinical studies in the past have shown BNCT to be highly effective for malignant melanoma of the skin, to apply BNCT for superficial lesions using this system it is necessary to shift the thermal neutron distribution so that the maximum dose occurs near the surface. A dose distribution shifter was designed to fit inside the collimator to further moderate the neutrons to increase the surface dose and reduce the dose to the underlying normal tissue. Pure polyethylene was selected, and a Monte Carlo simulation was performed to determine the optimum thickness of the polyethylene slab. Compared with the original neutron beam, the shifter increased the thermal neutron flux at the skin by approximately 4 times. The measured and simulated central axis depth distribution and off axis distribution of the thermal neutron flux were found to be in good agreement. Compared with a 2 cm thick water equivalent bolus, a 26% increase in the thermal neutron flux at the surface was obtained, which would reduce the treatment time by approximately 29%. The DDS is a safe, simple and an effective tool for the treatment of superficial tumours for BNCT if an initially fast neutron beam requires moderation to maximise the thermal neutron flux at the tissue surface

    Electric field and tip geometry effects on dielectrophoretic growth of carbon nanotube nanofibrils on scanning probes

    Full text link
    Single-wall carbon nanotube (SWNT) nanofibrils were assembled onto a variety of conductive scanning probes including atomic force microscope (AFM) tips and scanning tunnelling microscope (STM) needles using positive dielectrophoresis (DEP). The magnitude of the applied electric field was varied in the range of 1-20 V to investigate its effect on the dimensions of the assembled SWNT nanofibrils. Both length and diameter grew asymptotically as voltage increased from 5 to 18 V. Below 4 V, stable attachment of SWNT nanofibrils could not be achieved due to the relatively weak DEP force versus Brownian motion. At voltages of 20 V and higher, low quality nanofibrils resulted from incorporating large amounts of impurities. For intermediate voltages, optimal nanofibrils were achieved, though pivotal to this assembly is the wetting behaviour upon tip immersion in the SWNT suspension drop. This process was monitored in situ to correlate wetting angle and probe geometry (cone angles and tip height), revealing that probes with narrow cone angles and long shanks are optimal. It is proposed that this results from less wetting of the probe apex, and therefore reduces capillary forces and especially force transients during the nanofibril drawing process. Relatively rigid probes (force constant >= 2 N/m) exhibited no perceivable cantilever bending upon wetting and de-wetting, resulting in the most stable process control

    Integral Grothendieck-Riemann-Roch theorem

    Full text link
    We show that, in characteristic zero, the obvious integral version of the Grothendieck-Riemann-Roch formula obtained by clearing the denominators of the Todd and Chern characters is true (without having to divide the Chow groups by their torsion subgroups). The proof introduces an alternative to Grothendieck's strategy: we use resolution of singularities and the weak factorization theorem for birational maps.Comment: 24 page

    AlN/AlGaN HEMTs on AlN substrate for stable high-temperature operation

    Get PDF
    We demonstrate an AlN/AlGaN high-electron-mobility transistor (HEMT) fabricated on a free-standing AlN substrate. A metal stack, composed of Zr/Al/Mo/Au, was found to show low contact resistivity for source and drain ohmic contacts. The fabricated AlN/AlGaN HEMT exhibited a maximum drain current of 38 mA/mm with a threshold voltage of -3.4 V. Negligible drain current degradation was observed at temperatures from 300 to 573 K, emonstrating that our AlN/AlGaN approach on an AlN substrate is promising for stable high-temperature operation

    Dimension of the Torelli group for Out(F_n)

    Full text link
    Let T_n be the kernel of the natural map from Out(F_n) to GL(n,Z). We use combinatorial Morse theory to prove that T_n has an Eilenberg-MacLane space which is (2n-4)-dimensional and that H_{2n-4}(T_n,Z) is not finitely generated (n at least 3). In particular, this recovers the result of Krstic-McCool that T_3 is not finitely presented. We also give a new proof of the fact, due to Magnus, that T_n is finitely generated.Comment: 27 pages, 9 figure

    Lack of association with interleukin 1 receptor antagonist and interleukin-1 β gene polymorphisms in sarcoidosis patients

    Get PDF
    AbstractInterleukin-1 β (IL-1 β) and its endogenous antagonist, the interleukin-1 receptor antagonist (IL-1ra), play important roles in immune responses. In sarcoidosis, IL-1 β is reported to be increased whereas IL-1ra is decreased. It has recently been shown that polymorphisms in the IL-1ra and IL-1 β genes may account for variation in the two proteins. These polymorphisms are also reported to be associated with several autoimmune diseases. Since this might be expected to affect sarcoidosis, an investigation of 108 sarcoidosis patients and 113 healthy control subjects was performed.The IL-1ra genotype was determined using the polymerase chain reaction (PCR), and the IL-1β genotype by PCR restriction fragment length polymorphism.We found no significant differences in IL-ra and IL-1 β genotypes between sarcoidosis patients and healthy controls. Furthermore, there was no association between the IL-1 β genotype and the roentgenographic stage, disappearance of chest X-ray shadows or organ involvement.In conclusion, there is no bias in the IL-1ra and IL-1 β genotype in Japanese sarcoidosis patients

    Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    Get PDF
    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results
    corecore