6 research outputs found

    Tetralogy of Fallot with restrictive ventricular septal defect by accessory tricuspid leaflet tissue

    No full text
    In tetralogy of Fallot septal defect is usually large because of malalignment of outlet septum, restrictive defect has been reported rarely. We present a case of tetralogy of Fallot with accessory tricuspid leaflet tissue restricting ventricular septal defect. The report includes echocardiographic and catheter images of this rare presentation of tetralogy of Fallot

    Is accelerated idioventricular rhythm a good marker for reperfusion after streptokinase?

    No full text
    Background: Accelerated idioventricular rhythm (AIVR) is a common arrhythmia observed in patients with ST segment elevation myocardial infarction (MI). It is not clear how much value AIVR has in predicting successful reperfusion, since there have been conflicting data regarding this in the past. Streptokinase (STK) even today is the commonest thrombolytic agent used in the public health care set-up in India.1 Most data for the use of STK are from the 1990s, which had showed that at best it is effective in only 50% of patients in restoring adequate flow.2 It is probable that with the current dual-antiplatelet loading dose regimen and other newer medications, this figure could be higher. Also, rescue angioplasty for failed thrombolysis is the standard of care now, unlike before. Hence, we need reliable non-invasive markers to judge successful reperfusion in the present era. While ST segment resolution is the standard marker for reperfusion used in thrombolytic trials, in several instances it is not definitive. An additional marker would thus be very useful, especially in such cases. Methods: This was a prospective observational study carried out at a public teaching hospital. 200 consecutive patients with a diagnosis of acute MI who were given STK within 12 h of index pain were included. The STK dose was 1.5 million units, infused over 30 min; the ECG was again recorded after 90 min of completion of the infusion. Continuous ECG monitoring for the first 24 h of ICCU stay was performed and AIVRs during this period were documented. Early AIVR was defined as that occurring within 2 h of completing the STK infusion. Echocardiography was performed 24 h after presentation. The time course of AIVR was studied vis-a-vis the outcome of thrombolysis. Results: AIVR was seen in 41% of the patients. Though AIVR was found to have low sensitivity (45%) and specificity (64%) as a predictor of successful thrombolysis, early AIVR was a reliable sign of successful thrombolysis (p < 0.05). The sensitivity (45%) of early AIVR was low; however, the specificity (94%) and positive predictive value (94%) were very good. Conclusion: AIVR is a common arrhythmia in the setting of STEMI receiving thrombolytic therapy. Early AIVR is more common with successful thrombolysis, with an excellent positive predictive value. Thus, early AIVR can be used as an additive criterion to ST segment resolution as a non-invasive marker of successful thrombolysis with STK

    Precision measurement of the mass difference between light nuclei and anti-nuclei

    No full text
    The measurement of the mass differences for systems bound by the strong force has reached a very high precision with protons and anti-protons1,2. The extension of such measurement from (anti-)baryons to (anti-)nuclei allows one to probe any difference in the interactions between nucleons and anti-nucleons encoded in the (anti-)nuclei masses. This force is a remnant of the underlying strong interaction among quarks and gluons and can be described by effective theories3, but cannot yet be directly derived from quantum chromodynamics. Here we report a measurement of the difference between the ratios of the mass and charge of deuterons (d) and anti-deuterons (), and 3He and nuclei carried out with the ALICE (A Large Ion Collider Experiment)4 detector in Pb–Pb collisions at a centre-of-mass energy per nucleon pair of 2.76 TeV. Our direct measurement of the mass-over-charge differences confirms CPT invariance to an unprecedented precision in the sector of light nuclei5,6. This fundamental symmetry of nature, which exchanges particles with anti-particles, implies that all physics laws are the same under the simultaneous reversal of charge(s) (charge conjugation C), reflection of spatial coordinates (parity transformation P) and time inversion (T)

    Management of coronary disease in patients with advanced kidney disease

    No full text
    BACKGROUND Clinical trials that have assessed the effect of revascularization in patients with stable coronary disease have routinely excluded those with advanced chronic kidney disease. METHODS We randomly assigned 777 patients with advanced kidney disease and moderate or severe ischemia on stress testing to be treated with an initial invasive strategy consisting of coronary angiography and revascularization (if appropriate) added to medical therapy or an initial conservative strategy consisting of medical therapy alone and angiography reserved for those in whom medical therapy had failed. The primary outcome was a composite of death or nonfatal myocardial infarction. A key secondary outcome was a composite of death, nonfatal myocardial infarction, or hospitalization for unstable angina, heart failure, or resuscitated cardiac arrest. RESULTS At a median follow-up of 2.2 years, a primary outcome event had occurred in 123 patients in the invasive-strategy group and in 129 patients in the conservative-strategy group (estimated 3-year event rate, 36.4% vs. 36.7%; adjusted hazard ratio, 1.01; 95% confidence interval [CI], 0.79 to 1.29; P=0.95). Results for the key secondary outcome were similar (38.5% vs. 39.7%; hazard ratio, 1.01; 95% CI, 0.79 to 1.29). The invasive strategy was associated with a higher incidence of stroke than the conservative strategy (hazard ratio, 3.76; 95% CI, 1.52 to 9.32; P=0.004) and with a higher incidence of death or initiation of dialysis (hazard ratio, 1.48; 95% CI, 1.04 to 2.11; P=0.03). CONCLUSIONS Among patients with stable coronary disease, advanced chronic kidney disease, and moderate or severe ischemia, we did not find evidence that an initial invasive strategy, as compared with an initial conservative strategy, reduced the risk of death or nonfatal myocardial infarction

    Measuring KS0K± interactions using Pb–Pb collisions at √sNN=2.76 TeV

    No full text
    We present the first ever measurements of femtoscopic correlations between the K0 S and K± particles. The analysis was performed on the data from Pb–Pb collisions at √sNN = 2.76 TeV measured by the ALICE experiment. The observed femtoscopic correlations are consistent with final-state interactions proceeding via the a0(980) resonance. The extracted kaon source radius and correlation strength parameters for K0 SK− are found to be equal within the experimental uncertainties to those for K0 SK+. Comparing the results of the present study with those from published identical-kaon femtoscopic studies by ALICE, mass and coupling parameters for the a0 resonance are tested. Our results are also compatible with the interpretation of the a0 having a tetraquark structure instead of that of a diquar

    Diet and inflammatory bowel disease: The Asian Working Group guidelines

    No full text
    corecore