140,395 research outputs found

    Experimental investigation of small diameter two-phase closed thermosyphons charged with water, FC-84, FC-77 and FC-3283

    Get PDF
    Copyright © 2009 Elsevier Ltd. All rights reserved.An experimental investigation of the performance of thermosyphons charged with water as well as the dielectric heat transfer liquids FC-84, FC-77 and FC-3283 has been carried out. The copper thermosyphon was 200 mm long with an inner diameter of 6 mm, which can be considered quite small compared with the vast majority of thermosyphons reported in the open literature. The evaporator length was 40 mm and the condenser length was 60 mm which corresponds with what might be expected in compact heat exchangers. With water as the working fluid two fluid loadings were investigated, that being 0.6 ml and 1.8 ml, corresponding to approximately half filled and overfilled evaporator section in order to ensure combined pool boiling and thin film evaporation/boiling and pool boiling only conditions, respectively. For the Fluorinert™ liquids, only the higher fill volume was tested as the aim was to investigate pool boiling opposed to thin film evaporation. Generally, the water-charged thermosyphon evaporator and condenser heat transfer characteristics compared well with available predictive correlations and theories. The thermal performance of the water-charged thermosyphon also outperformed the other three working fluids in both the effective thermal resistance as well as maximum heat transport capabilities. Even so, FC-84, the lowest saturation temperature fluid tested, shows marginal improvement in the heat transfer at low operating temperatures. All of the tested Fluorinert™ liquids offer the advantage of being dielectric fluids, which may be better suited for sensitive electronics cooling applications and were all found to provide adequate thermal performance up to approximately 30–50 W after which liquid entrainment compromised their performance

    A study on the intensive use of air conditioning in large retail stores

    Get PDF
    In addition to an increase in greenhouse effect emissions the intensive use of air conditioning in the retail sector can eventually carry implications on the health of some of those directly exposed to sudden cooling particularly in hot summer days. This paper reports the results of an experimental study conducted in the summer of 2005 in the United Kingdom investigating air conditioning frequency of use and the indoor air temperatures of air conditioned premises. It was found that in some large retail stores indoor air temperatures could be set higher improving thermal comfort and contributing towards the environment

    Using the simple peel test to measure the adhesive fracture energy, Ga

    Get PDF
    The adhesive fracture energy of structural adhesive joints may be readily ascertained from linear-elastic fracture-mechanics (LEFM) methods, and indeed an ISO Test Method (ISO 25217: 2009) now exists for the LEFM Mode I value, Gc, as a result of the efforts of the European Structural Integrity Society (ESIS) ‘TC4 Committee’ [1,2]. These LEFM test methods involve the preparation and testing of adhesively-bonded double-cantilever beam (DCB) and tapered double-cantilever beam (TDCB) specimens [3,4]. Notwithstanding the sound and reproducible results that may be obtained from such methods, the LEFM test specimens are relatively complex and expensive to make and test, and many industries would far prefer to deduce the value of the adhesive fracture energy from the very common and widely-used ‘peel test’. (In the present paper, for clarity, the adhesive fracture energy is termed GA when deduced from a peel test.) Indeed, the peel test is an attractive test method to assess the fracture performance of a wide range of structural adhesive joints and flexible laminates. However, although it is a relatively simple test to undertake, it is often a complex test to analyse and thus obtain a characteristic measure of the toughness of the adhesive joint, or laminate

    PDEs in Moving Time Dependent Domains

    Full text link
    In this work we study partial differential equations defined in a domain that moves in time according to the flow of a given ordinary differential equation, starting out of a given initial domain. We first derive a formulation for a particular case of partial differential equations known as balance equations. For this kind of equations we find the equivalent partial differential equations in the initial domain and later we study some particular cases with and without diffusion. We also analyze general second order differential equations, not necessarily of balance type. The equations without diffusion are solved using the characteristics method. We also prove that the diffusion equations, endowed with Dirichlet boundary conditions and initial data, are well posed in the moving domain. For this we show that the principal part of the equivalent equation in the initial domain is uniformly elliptic. We then prove a version of the weak maximum principle for an equation in a moving domain. Finally we perform suitable energy estimates in the moving domain and give sufficient conditions for the solution to converge to zero as time goes to infinity.Comment: pp 559-577. Without Bounds: A Scientific Canvas of Nonlinearity and Complex Dynamics (2013) p. 36

    The year in cardiology: arrhythmias and pacing.

    Get PDF
    During this last year, there has been much progress with regard to anticoagulant and ablation therapy for atrial fibrillation (AF). Apart from recently issued European Society of Cardiology Guidelines for the management of patients with supraventricular arrhythmias, there has been little progress in research in this field. Ventricular arrhythmias and device therapy have seen modest progress

    Transverse mass and invariant mass observables for measuring the mass of a semi-invisibly decaying heavy particle

    Full text link
    Formulae are derived for the positions of end-points in the invariant mass and transverse mass distributions obtained from the products of heavy states decaying to pairs of semi-invisibly decaying lighter states. Formulae are derived both for the special case where the two decay chains are identical and the more general case where they are different. The formulae are tested with a simple case study of heavy SUSY higgs particles decaying to gauginos at the LHC.Comment: 13 pages, 8 eps figure

    Numerical and Experimental Investigation of the Morphology Development of Expansion Clouds by a Powder Jet Flow

    Get PDF
    Explosion suppression is often the preferred method of explosion attenuation in industry. The morphology development of suppression clouds is important for the design of necessary coverage of the product. This paper presents a numerical and experimental investigation of the growth of powder dispersion as it expands from a discharge nozzle. A Lagrangian stochastic particle-tracking approach and the RNG k-e turbulence model are adopted in the flow field solver for the dispersed and continuous phases. The flow fields coupled with the particle interactions are predicted. The dispersion characteristics of the expansion of the powder cloud through a pipe for short intervals of time are investigated. This was compared with (1) captured images from experiments, (2) experimental data, and (3) results of previous simulations. Particle positions along the jet are presented. The effects of flow rate on the development of the cloud and a comparison with experimental results are also presented. It is noted that the coverage of the powder cloud can be controlled by the flow rate of the jet, and the developing length of the cloud is more influenced by the flow rate of jet flow than the developing width. The good qualitative agreements achieved are useful for further optimisation of product design
    corecore